   if Autonotify = 1, UCIMAG will send the message 

TRACK DATA READY

 as soon as the card

   has been swiped. The user can then poll the data with :Tn command.

  :Jb

  - Include start (%) and end (?) characters in track data, if b=0 disable, if b=1 enable

  :RTt

  - Select Reader type (determines which card load signals to use)

     0 = swipe,

     1= half insertion using 2 sensors,

     2= full insertion,

     3= half insertion using only 1 sensor in back,

     4= half insertion using 1 sensor in front,

     5= half insertion with 2 s card load signal,

     Returns: reader status

9.3 UCIMAG Status Commands

  

:SR

  - Send reader status, its configuration

       Returns: SR:ABCI.scnde.xyz.t.<sh><sl><CR><LF>

  Where:

A=CardLoad1 signal = 0 or 1

B=CardLoad2 signal = 0 or 1

C=CardLoad3 signal = 0 or 1

I=CardInserted signal = 0 or 1

s=AutoSend configuration bit = 0 or 1

c=AutoClear configuration bit = 0 or 1

n=AutoNotify configuration bit = 0 or 1

d=direction configuration bit = 0 or 1 (1 = reverse)

e=UseStartEnd configuration bit = 0 or 1

x=Track 1 enable bit = 0 or 1 (1=enabled)

x=Track 2 enable bit = 0 or 1 (1=enabled)

x=Track 3 enable bit = 0 or 1 (1=enabled)

t=Reader Type character = 0,1,2,3 see RT command

  :ST

  - Send track status

       Returns: <LF>ST:dsercc.dsercc.dsercc.<sh><sl><CR><LF>

  Where:

d= data was detected on track

s= start character was detected

e = end character was detected

r = LRC check was passed

cc = two characters representing the hex value of byte count of track first set of

                         

dsercc

 is for track 1, second set is for track 2, and third set is for track 3

  :V

  - Send Firmware Version

Returns: Panasonic UCIMAG vx.xx Copyright xxxx

Содержание ZU-1870MA101

Страница 1: ...F I C A T I O N F O R M A G N E T I C C A R D R E A D E R M a n u a l I n s e r t I o n t y p e W I T H R S 2 3 2 C I n t e r f a c e Z U 1 8 7 0 M A 1 0 1 MATSUSHITA ELECTRIC INDUSTRIAL CO LTD MATSUS...

Страница 2: ...R E V I S E D R E C O R D Date Document No Contents of revision Page...

Страница 3: ...SPECIFICATION 4 5 BASIC FEATURES 4 6 CARD STANDARD 5 7 CIRCUIT CONSTRUCTION 6 8 ENVIRONMENTAL CHARACTERISTICS 7 9 HOST RS 232 COMMANDS 8 10 ERROR HANDLING 9 11 UNIT LIFE AND RELIABILITY 10 12 MAINTENA...

Страница 4: ...l insertion type 2 2 Model No ZU 1870MA101 3 FUNCTION 3 1 Card operation Insertion Ejection 3 2 Read Write Read only 3 3 Read direction Backward Ejection 4 EQUIPMENT SPECIFICATION 4 1 Out dimension 90...

Страница 5: ...5 bit code FM 6 2 Location of tracks ISO 2 Tracks ISO 7810 ISO 7811 Coercive force Hc 2 4 10 2 4 10 A m 300 3000 Oe unit mm 5 66 max 8 46 8 97 85 47 85 72 8 97 8 46 11 76 12 27 7 44 0 51 Track1 2 12 5...

Страница 6: ...me CN1 Card Reader Signal Name X1 UCIMAG Signal Name 1 5 VDC 3 5 VDC 2 RDT1 7 RDT1 3 RCL1 8 RCL1 4 RDT2 4 RDT2 5 RCL2 5 RCL2 6 CLD 6 CLD2 7 GND 2 GND 1 NC 9 NC 10 NC 11 NC 12 NC Note Vcc on UCIMAG com...

Страница 7: ...d to sample the data line by it s falling edge READ CLOCK 3 RDT1 RDT2 The moment RCL changes from High to Low RDT is 1 READ DATA when the RDT1 RDT2 RDT line is Low and RDT is 0 when the RDT line is Hi...

Страница 8: ...begin with a as shown and end with CR not shown CR ASCII carriage return character 0DH LF ASCII line feed character 0AH sh high digit of 8 bit hexadecimal checksum sl low digit of 8 bit hexadecimal ch...

Страница 9: ...ardLoad2 signal 0 or 1 C CardLoad3 signal 0 or 1 I CardInserted signal 0 or 1 s AutoSend configuration bit 0 or 1 c AutoClear configuration bit 0 or 1 n AutoNotify configuration bit 0 or 1 d direction...

Страница 10: ...the track data a T1 error cr lf Ct Clear track t Dt Raw hex dump of track t Hb Enable disable auto dumping of tracks for debug only 9 5 UCIMAG LED Commands Ib Set LED output on or off b 0 means off b...

Страница 11: ...n 1 second a communication error has occurred and the command should be resent 10 3 Power Failure If power fails and is then restored the unit is reset and reinitialized On reset the UCIMAG will send...

Страница 12: ...O standard Anti magnetic of the applied card should be 2 4 10 A m 2 4 10 A m of ISO standard 2 Card operation speed should be within the specification range Forced stop or change of speed during the c...

Страница 13: ...1AA Connector Attachment Hole Attachment Hole Magnetic Card Card Entrance Slot Black X4 5 APPEARANCE General Tolerance 0 5 unit mm Body 2 Body 1 Transparence Transparence 90 1 7 5 7 61 2 9 46 4 5 90 3...

Страница 14: ...1 Pin No CN2 Pin No 1 DTR 1 CD 2 RTS 2 RXD 3 TX 3 TXD 4 RCV 4 DTR 5 GND 5 GND 6 DSR External 5V 7 RTS GND 8 CTS 9 RI NG 1 Cabl e No ZUHTS0040 2 Cabl e Di mensi on Card Reader side System side CN1 CN1...

Отзывы: