background image

SPEC. No.

MES-DG60BA001

S P E C I F I C A T I O N

F O R

M A G N E T I C  C A R D  R E A D E R

(  M a n u a l  I n s e r t I o n  t y p e  )

W I T H

R S – 2 3 2 C  I n t e r f a c e

Z U –

 1 8 7 0 M A 1 0 1

MATSUSHITA ELECTRIC INDUSTRIAL CO., LTD.

MATSUSHITA INDUSTRIAL EQUIPMENT CO., LTD.

Содержание ZU-1870MA101

Страница 1: ...F I C A T I O N F O R M A G N E T I C C A R D R E A D E R M a n u a l I n s e r t I o n t y p e W I T H R S 2 3 2 C I n t e r f a c e Z U 1 8 7 0 M A 1 0 1 MATSUSHITA ELECTRIC INDUSTRIAL CO LTD MATSUS...

Страница 2: ...R E V I S E D R E C O R D Date Document No Contents of revision Page...

Страница 3: ...SPECIFICATION 4 5 BASIC FEATURES 4 6 CARD STANDARD 5 7 CIRCUIT CONSTRUCTION 6 8 ENVIRONMENTAL CHARACTERISTICS 7 9 HOST RS 232 COMMANDS 8 10 ERROR HANDLING 9 11 UNIT LIFE AND RELIABILITY 10 12 MAINTENA...

Страница 4: ...l insertion type 2 2 Model No ZU 1870MA101 3 FUNCTION 3 1 Card operation Insertion Ejection 3 2 Read Write Read only 3 3 Read direction Backward Ejection 4 EQUIPMENT SPECIFICATION 4 1 Out dimension 90...

Страница 5: ...5 bit code FM 6 2 Location of tracks ISO 2 Tracks ISO 7810 ISO 7811 Coercive force Hc 2 4 10 2 4 10 A m 300 3000 Oe unit mm 5 66 max 8 46 8 97 85 47 85 72 8 97 8 46 11 76 12 27 7 44 0 51 Track1 2 12 5...

Страница 6: ...me CN1 Card Reader Signal Name X1 UCIMAG Signal Name 1 5 VDC 3 5 VDC 2 RDT1 7 RDT1 3 RCL1 8 RCL1 4 RDT2 4 RDT2 5 RCL2 5 RCL2 6 CLD 6 CLD2 7 GND 2 GND 1 NC 9 NC 10 NC 11 NC 12 NC Note Vcc on UCIMAG com...

Страница 7: ...d to sample the data line by it s falling edge READ CLOCK 3 RDT1 RDT2 The moment RCL changes from High to Low RDT is 1 READ DATA when the RDT1 RDT2 RDT line is Low and RDT is 0 when the RDT line is Hi...

Страница 8: ...begin with a as shown and end with CR not shown CR ASCII carriage return character 0DH LF ASCII line feed character 0AH sh high digit of 8 bit hexadecimal checksum sl low digit of 8 bit hexadecimal ch...

Страница 9: ...ardLoad2 signal 0 or 1 C CardLoad3 signal 0 or 1 I CardInserted signal 0 or 1 s AutoSend configuration bit 0 or 1 c AutoClear configuration bit 0 or 1 n AutoNotify configuration bit 0 or 1 d direction...

Страница 10: ...the track data a T1 error cr lf Ct Clear track t Dt Raw hex dump of track t Hb Enable disable auto dumping of tracks for debug only 9 5 UCIMAG LED Commands Ib Set LED output on or off b 0 means off b...

Страница 11: ...n 1 second a communication error has occurred and the command should be resent 10 3 Power Failure If power fails and is then restored the unit is reset and reinitialized On reset the UCIMAG will send...

Страница 12: ...O standard Anti magnetic of the applied card should be 2 4 10 A m 2 4 10 A m of ISO standard 2 Card operation speed should be within the specification range Forced stop or change of speed during the c...

Страница 13: ...1AA Connector Attachment Hole Attachment Hole Magnetic Card Card Entrance Slot Black X4 5 APPEARANCE General Tolerance 0 5 unit mm Body 2 Body 1 Transparence Transparence 90 1 7 5 7 61 2 9 46 4 5 90 3...

Страница 14: ...1 Pin No CN2 Pin No 1 DTR 1 CD 2 RTS 2 RXD 3 TX 3 TXD 4 RCV 4 DTR 5 GND 5 GND 6 DSR External 5V 7 RTS GND 8 CTS 9 RI NG 1 Cabl e No ZUHTS0040 2 Cabl e Di mensi on Card Reader side System side CN1 CN1...