15.2. INITIAL POWER + BBIC TESTS
1. Turn on the 3.9V supply.
2. Press the “Power-on” button.
3. Check for a “beep” and approx 80 mA current on the 3.9V supply.
4. Check the 3.0V supply voltage (TP10). It must be 2.85 +/- 0.3.
5. Connect RFCLK (TP56) to CH.1 on the scope. Send batch file
RFCLK1.
6. Check if the clock waveform is 10,368.000 kHz, +/- 40Hz.
7. Send batch file ”SELF TEST”. The first 4 digits are FLASH ROM
checksum, the next 2 digits are RAM test, and must be 00.
15.3. SET CLOCK FREQUENCY
1. Send batch file “RFCLK1”.
2. Connect RFCLK (TP56) to the frequency counter.
3. Send batch file “SET FREQ nn” to set the clock frequency. The
default value of nn is 80. Increase the value to increase the
frequency. The clock frequency must be 10,368.000 kHz ± 0.04 kHz.
15.4. QUICK Tx CHECK
1. Set the CMD60 to MODULE TEST.
33
Содержание KX-TCD952NLB
Страница 2: ...1 LOCATION OF CONTROLS 2...
Страница 3: ...2 DISASSEMBLY INSTRUCUTIONS 3...
Страница 9: ...4 4 SELECTING THE HANDSET RINGER VOLUME 4 5 SELECTING THE BASE UNIT RINGER VOLUME 9...
Страница 11: ...6 BLOCK DIAGRAM RF UNIT BASE UNIT 11...
Страница 12: ...7 BLOCK DIAGRAM BASEBAND SECTION AND LINE INTERFACE BASE UNIT 12...
Страница 20: ...9 BLOCK DIAGRAM RF UNIT HANDSET 20...
Страница 21: ...10 BLOCK DIAGRAM BASE BAND SECTION HANDSET 21...
Страница 36: ...36...
Страница 37: ...16 2 HANDSET LINK 37...
Страница 38: ...38...
Страница 39: ...39...
Страница 40: ...16 3 HANDSET DOES NOT LINK 16 4 BASE UNIT DOES NOT CHARGE 40...
Страница 41: ...16 5 HANDSET DOES NOT CHARGE 41...
Страница 42: ...16 6 NO VOICE RECEPTION 42...
Страница 43: ...16 7 NO VOICE TRANSMISSION 16 8 BASE UNIT DOES NOT LINK 43...
Страница 44: ...17 CABINET AND ELECTRICAL PARTS LOCATION BASE UNIT 44...
Страница 45: ...18 CABINET AND ELECTRICAL PARTS LOCATION HANDSET 45...
Страница 46: ...19 ACCESSORIES AND PACKING MATERIALS 46...
Страница 58: ...22 1 SCHEMATIC DIAGRAM HANDSET U Q KXTCD952NLB UK Printed in Japan 58...