Specifications
7kW,10kW models are also available.
Output control
Voltage regulation
Current regulation
Stability
Temperature coefficient
Output display
Monitor output
Protections
Local: Constant voltage: rotary encoder on front panel
Constant current: rotary encoder on front panel
Remote: Constant voltage: external control voltage 0Vdc to 10Vdc or external variable resistor 0
to approx. 10k
Constant current: external control voltage 0Vdc to 10Vdc or external variable resistor 0
to apporox. 10k
Line: 0.01% of maximum output (for 100Vac to 250Vac±10% input change)
Load: 0.01%+2mV of maximum output (for 10% to 100% load change)
Line: 0.01% of maximum output (for 100Vac to 250Vac±10% input change)
Load: 0.02%+5mA of maximum output (for 10% to 100% load change)
0.05%/8Hr of maximum output voltage
0.01% / °C of maximum output voltage
0.04% / °C of maximum output current
Output voltage: 4-digit meter (±0.5%FS±1digit at 23°C±5°C)
Output current: 4-digit meter (±0.5%FS±1digit at 23°C±5°C)
Output voltage monitor: 10V / maximum output voltage
Output current monitor: 10V / maximum output current
Over voltage protection (OVP) Output is cut off at a set value.
Over current protection(OCP) Output is cut off at a set value.
Setting range: 5% to 110% of rated output
Local setting: Rotary encoder on front panel
Reset: Manual recovery by OUTPUT switch or remote switch.
Over temperature protection (OTP)
Output is cut off when internal part is heated abnormally.
Reset (after the temperature has gone down to normal):
Manual recovery by OUTPUT switch or remote switch.
Input brownout(ACF)·Blackout protection
Output is cut off when input voltage decreased.
Reset (when normal voltage value or recovery from blackout):
Manual recovery by OUTPUT switch or remote switch
for blackout protection (re-output protection function).
Automatic recovery when blackout protection is canceled.
Sense reverse connection
Interlock
Other functions
Transient response time
Operation temperature
Storage temperature
Storage humidity
Dielectric voltage
Accessories
50
Temp
(°C)
Input
Voltage
(V)
Input
Voltage
(V)
Output
Power
(kW)
40
85 100 120
200
240 264
1.6
1.2
85 100 120
200
240 264
Keylock to avoid misoperation.
Digital master slave operation.(up to 250V for series operation)
(Max 32 units for parallel or series connection.)
(Combination of parallel and series is not possible.)
Setting memory function
Quiet forced air cooling
Remote sensing
Remote switch ON/OFF (TTL or external relay)
Status signal output (CV, CC, FLT, OUTPUT)
Delay trigger function : ON delay and OFF delay can be set individually
(0.0 to 99.9 sec)
Multi set function : Voltage and current memory "a", "b" and "c" can be
set in addition to standard preset function.
Recovery time 1ms (for 70%
100% load change)
1.6kW model 0°C to +50°C (when input is 120VAC to 264VAC.)
0°C to +40°C (when input is 85VAC to 120VAC.)
When the input voltage is below 100VAC,the
output power is to be derated at 1.2kW max.
2.5kW to 5.5kW model 0°C to +50°C
-20°C to +70°C
0% to 80% RH (no condensation)
Between input power supply and output terminal : AC2000V 1 minute
Between input power supply and chassis : AC2000V 1 minute
Between output terminal and chassis : DC1000V 1 minute
·Instruction manual (1) ·Output terminal cover (1)
·Remote connector cover (1) ·CO-M cable 2m (1) <when without option>
1.6kW
2.5kW
3.6kW
5.5kW
100VAC to 240VAC
200VAC to 240VAC
200VAC to 240VAC
200VAC to 240VAC
200VAC to 240VAC
380VAC to 415VAC
200VAC to 240VAC
380VAC to 415VAC
Input Voltage
(50/60Hz)
Phase
Input Current
*
1
Model
Standard
Standard
Option
-L(3P)
Option
-L(1P)
Standard
Option
-L(400V)
Standard
Option
-L(400V)
23A @ 100V
16A @ 200V
10A @ 200V
26A @ 200V
16A @ 200V
8A @ 400V
24A @ 200V
12A @400V
1Ø
1Ø
3Ø
1Ø
3Ø
3Ø
3Ø
3Ø
*1 : At maximum output power
*2:Rated input voltage range is between 100 to 240VAC(50/60Hz)while applying CE mark.
Input Voltage
Input Current
Fuse 30A
Fuse 30A
Fuse 30A
Fuse 30A
Fuse 30A
Fuse 30A
Fuse 15A
Fuse 15A
Input Current Protection
Power factor : 0.99 typ.( )
1Ø
0.95 typ.( )
3Ø
07