background image

Lineup

At 10 to 100% of rated output voltage and rated output current.

Please inquire the situation of CE certification. It is under procedure.
A power supply with -LDc option, -LDe option and -LEt option doesn't have CE marking.(Please refer to page 5 for -LDc option and -LDe option, and page 10 for -LEt.) 

MODEL

(mVrms)

(mArms)

*

Output Voltage

(V)

Output Current

(A)

Output Power

(W)

Ripple

0 to 6

0 to 8

0 to 10

0 to 15

0 to 20

0 to 30

0 to 35

0 to 45

0 to 60

0 to 80

0 to 100

0 to 150

0 to 200

0 to 300

0 to 500

0 to 600

0 to 650

1300
1860
3200
4800
1500
2400
3400
5100
1500
2400
3400
5100
1600
2500
3400
5200
1600
2500
3450
5400
1600
2500
3500
5400
1600
2500
3500
5400
1600
2500
3600
5400
1600
2500
3600
5440
1600
2500
3600
5500
1500
2500
3600
5400
1600
2500
3600
5400
1600
2500
3600
5400
1600
2500
3500
5500
1600
2500
3600
5400
1600
2500
3600
5500

0 to 220
0 to 310
0 to 530
0 to 600
0 to 150
0 to 240
0 to 340
0 to 510
0 to 100
0 to 160
0 to 227
0 to 340
0 to 80
0 to 125
0 to 170
0 to 260
0 to 53
0 to 84
0 to 115
0 to 180
0 to 45
0 to 72
0 to 100
0 to 155
0 to 35
0 to 55
0 to 78
0 to 120
0 to 26
0 to 42
0 to 60
0 to 90
0 to 20
0 to 31
0 to 45
0 to 68
0 to 16
0 to 25
0 to 36
0 to 55
0 to 10
0 to 16.6
0 to 24
0 to 36
0 to 8
0 to 12.5
0 to 18
0 to 27
0 to 5.3
0 to 8.3
0 to 12
0 to 18
0 to 3.2
0 to 5
0 to 7
0 to 11
0 to 2.7
0 to 4.1
0 to 6
0 to 9
0 to 2.5
0 to 3.8
0 to 5.5
0 to 8.5

10
10
10
10
10
10
10
10
10
10
10
15
10
12
15
15
20
20
20
20
20
20
30
30
20
30
30
30
20
18
30
30
20
20
30
30
20
25
30
30
30
25
30
30
40
40
40
40
50
50
50
50

100
100
100
100
150
150
150
150
150
150
150
150

320

1500

900

3000

300
500
900

3000

150
300
500
600
160
250
300
400
100
160
200
260

90

150
230
280

70

100
130
180

50
80

100
135

40
60
80

100

25
50
60
80
20
35
40
55
15
25
30
40
10
18
20
30

5

12
15
20

5

10
15
15

5

10
15
15

REK6-220
REK6-310
REK6-530
REK8-600
REK10-150
REK10-240
REK10-340
REK10-510
REK15-100
REK15-160
REK15-227
REK15-340
REK20-80
REK20-125
REK20-170
REK20-260
REK30-53
REK30-84
REK30-115
REK30-180
REK35-45
REK35-72
REK35-100
REK35-155
REK45-35
REK45-55
REK45-78
REK45-120
REK60-26
REK60-42
REK60-60
REK60-90
REK80-20
REK80-31
REK80-45
REK80-68
REK100-16
REK100-25
REK100-36
REK100-55
REK150-10
REK150-16.6
REK150-24
REK150-36
REK200-8
REK200-12.5
REK200-18
REK200-27
REK300-5.3
REK300-8.3
REK300-12
REK300-18
REK500-3.2
REK500-5
REK500-7
REK500-11
REK600-2.7
REK600-4.1
REK600-6
REK600-9
REK650-2.5
REK650-3.8
REK650-5.5
REK650-8.5

Please contact our ofiice near you.

7kW,10kW models are also available.

03

Содержание REK Series

Страница 1: ...nt Power Supply REK Series www matsusada com High power Versatile Programmable DC power supply Compact High power of 5 5kW except some models REK series NEW NEW except some models 6V to 650V 2 5A to 600A 1 6kW to 5 5kW ...

Страница 2: ...cise monitoring with better recognition Operability and safety are improved with new features of key lock function and acceleration rotary encoder which accelerate the output ramp up with the speed of rotating the encoder 7kW 10kW models are also available 1 6kW to 2 5kW models 3 6kW to 5 5kW models Featuring broad output range and low noise switching configuration REK series is an ideal power sup...

Страница 3: ... to 25 0 to 36 0 to 55 0 to 10 0 to 16 6 0 to 24 0 to 36 0 to 8 0 to 12 5 0 to 18 0 to 27 0 to 5 3 0 to 8 3 0 to 12 0 to 18 0 to 3 2 0 to 5 0 to 7 0 to 11 0 to 2 7 0 to 4 1 0 to 6 0 to 9 0 to 2 5 0 to 3 8 0 to 5 5 0 to 8 5 10 10 10 10 10 10 10 10 10 10 10 15 10 12 15 15 20 20 20 20 20 20 30 30 20 30 30 30 20 18 30 30 20 20 30 30 20 25 30 30 30 25 30 30 40 40 40 40 50 50 50 50 100 100 100 100 150 1...

Страница 4: ...output when different setting and convenient function for production inspection process or testing which require frequent data taking Memory a Memory b Memory c 3 Set voltage and current 1 2 Press down SET Select a memory with 3 buttons NOTE It is not possible to stabilize the output by controlling back current In case of load which has inverse voltage or over rated voltage such as inductive load ...

Страница 5: ...h range 1 0s to 99 9h respectively tb tc toff a b c ta t1 Note The operation accuracy of the timer when sequensing is 0 5 Be careful when you use it by the long term running operation t2 Output ON Output OFF t1 a c b ta t2 tb t3 tc t4 toff t1 and t2 can be set with range 0 to 999s respectively t1 t2 t3 and t4 can be set with range 0 to 999s respectively ta tb tc and toff can be set with range 0 0s...

Страница 6: ...ogramming display Light on when voltage current remote control Output preset switch OVP OCP setting switch Keylock setting switch Exhaust hole AC input terminal M4 Not Sink Current switch 1 10 11 12 13 14 15 16 17 18 2 3 4 5 6 7 8 9 Front Panel Rear Panel nt Panel 1 1 2 3 6 5 8 9 1 0 11 12 13 14 15 4 7 Voltage Control 0 to approx 10k Current Control Blackout Protection Io Load VL Vo R S S OUTPUT 0...

Страница 7: ...n Interlock Other functions Transient response time Operation temperature Storage temperature Storage humidity Dielectric voltage Accessories 50 Temp C Input Voltage V Input Voltage V Output Power kW 40 85 100 120 200 240 264 1 6 1 2 85 100 120 200 240 264 Keylock to avoid misoperation Digital master slave operation up to 250V for series operation Max 32 units for parallel or series connection Com...

Страница 8: ... V COM ON when OUTPUT ON when each mode FLT OUTPUT CV CC TB1 ON when fault CV CC Delay trigger function at Master Slave control can be set for each unit Furthermore delay trigger function at Master Slave control can cancel one control functions except for Output by switching Remote Local and can set voltage and current preset Possible to change 10k to 0 for fail safe A A A RS 232C RS 485 GPIB A CO...

Страница 9: ...8 35 0 18 4 5 16 85 428 16 81 427 2 36 60 17 17 436 4 M4 4 M4 3 Ø0 33 8 5 2 M6 1 38 35 0 18 4 5 16 85 428 16 81 427 2 36 60 17 17 436 Weight 8kg typ Weight 8kg typ Weight 14kg typ Weight 14kg typ 1 6kW 2 5kW Models 1 6kW 2 5kW Models 3 6kW 5 5kW Models 3 6kW 5 5kW Models O I 1 97 50 3 76 2 3 47 88 1 18 31 465 19 482 6 8 6x10 There are exhaust holes on rear panel for forced air cooling In case plac...

Страница 10: ... 1 CO G32 B 32 units can be connected to 1 CO E32 32 units can be connected to 1 CO U32 In case power supply will be use following condition make sure this options selected Noisy environment such as factories ex usage of motor and coil around load or power supply Usage on high voltage floating more than 250V In case the distance between power supply and controller PC or PLC is longer than 2 meter ...

Страница 11: ... is assured Important Notice F S catalog value is applied for ripple stability regulations and temperature coefficient and value if F S 1 is applied for high voltage output linearity monitor linearity and display linearity both in the range of 10 to 100 of maximum rating output Definition of specifications Connection Operation Applicable scope of specifications Please use a short lead wire that is...

Страница 12: ...ed to be defective as satisfactory to us we at our sole discretion repair or replace such defective Products at no cost to the purchaser We assume no liability to the purchaser or any third party for special incidental consequential or other damages resulting from a breach of the foregoing warranty This warranty excludes any and all other warranties not set forth herein express or implied includin...

Отзывы: