4 Advanced Operation
4-1
Matsusada Precision
AK series
4
Advanced Operation
4-1 Introduction
Explanation of Remote Programming Operations.
With this feature such functions as external voltage control or external monitor is available.
By using GP-IB/IEEE488 or RS 232C adapter (option), operation via PC is also possible.
4-2 Function of TB1 Interface Connector
List 4-1 Function of TB1 interface connector
TB1
SIGNAL
PARAMETER
1
Remote Voltage Program In
0 to 10Vdc input = 0 to 100% rated output
2
Remote Current Program In
0 to 10Vdc input = 0 to 100% rated output
3
Output Current Monitor
0 to 10Vdc output = 0 to 100% rated output
4
Spare (out of use)
5
Common (GND of Power Supply)
For 1, 2, 3, 14, 15
6
Spare (out of use)
7
Door switch (
Interlock)
Short = HV ON
8
Remote reset (for Option LO
c
,)
Short = reset
9
Spare (out of use)
10
Spare (out of use)
11
Spare (out of use)
12
Spare (out of use)
13
Spare (out of use)
14
Reference voltage output
Ref10.24V
,
4mA MAX output
15
Output Voltage Monitor
0 to 10Vdc output = 0 to 100% rated output
16
Spare (out of use)
17
Common
(
GND of Power Supply
)
For 7 , 8 , 19 , 20 , 21
18
Spare (out of use)
19
HV Status
HV ON = internally relay contact is shorted
20
Internal control/external control select
Short = External control,
Open = Internal
control
21
Remote switch ON/OFF
Short = HV ON Open = HV OFF
22
Spare (out of use)
23
Spare (out of use)
24
Spare (out of use)
25
Current Control: EXT/INT select
Internal current control
1
13
14
25
S2
TB1
Fig. 4-1 TB1 Connector
,
S2 Switch
20-17 short
25-2 short
Содержание AK Series
Страница 1: ...Instruction Manual F RA 001 3R2 MODEL AK series 3kW 4kW B N 030 9 010 030 9 010 Rev 1 0 ...
Страница 17: ...2 Exterior View Diagram 2 3 Matsusada Precision AK series 2 4 Dimensions 1 to 60kV ...
Страница 18: ...2 Exterior View Diagram 2 4 Matsusada Precision AK series 2 5 Dimensions 80 to 120kV Plastic foot ...
Страница 31: ...Matsusada Precision AK series ...
Страница 32: ......