![Matrix MR111SS Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/matrix/mr111ss/mr111ss_manual-for-installation-use-and-maintenance_1740321028.webp)
28
Setting up the Range Cooker for use
Regulation of the hob burner minimum flow rates
1.
Natural gas
Light the burner and turn it to the minimum position.
Remove the gas control knob and turn the adjustment
screw at the side of the valve shaft until the required
minimum flame is achieved.
2.
LPG
Remove the gas control knob and turn the adjustment
screw at the side of the valve shaft fully clockwise.
Once the above is complete, refit the knob and verify that the burner
flame is stable (the flame must not extinguish when turning the control
knob rapidly between maximum and minimum position). Leave
the control knob at the minimum position for one minute to check
the flame failure device function. The flame should not extinguish.
Repeat this process for all hob burner controls.
Fig.20
Содержание MR111SS
Страница 30: ...30 NOTES...