background image

State

Single LED

(tri color)

Buzzer

Power On

Blue (ON)

OFF

Idle Online

Blue (ON: 200ms
         OFF: 2200ms) 

OFF

Idle Offline/ 
Network Failure

Red (ON: 200ms
        OFF: 2200ms)

OFF

Degraded Mode

Orange (ON: 200ms
            OFF: 2200ms)

OFF

Processing

Green (ON: 200ms) 
Red (ON: 200ms)

OFF

Wait

Green (ON: 200ms)
Red (ON: 200ms
        OFF: 800ms) 

ON: 200ms
OFF: 1000ms

Alarm Minor

Red (ON: 200ms
        OFF: 1000ms)

ON: 200ms
OFF: 1000ms

Alarm Major

Red (ON: 400ms
        OFF: 800ms)

ON: 400ms
OFF: 800ms

Alarm Critical

Red (ON till Reset)

ON till Reset

31

LED and Buzzer Indications

32

ATOM RD100/200: Connected through RS-232/ RS-485

State

Single LED

(tri color)

Buzzer

Alarm Clear

OFF

OFF

Access Allowed

Green (ON: 1200ms)

ON: 1200ms

Access Denied

Red (ON: 200ms
        OFF: 200ms)
        3 Cycles

ON: 200ms
OFF: 200ms
3 Cycles

System Default

Red (ON: 400ms
        OFF: 200ms)

ON till Reset

Lost Connectivity
with the ARC 
Controller

Red (ON: 200ms
        OFF: 200ms)

OFF

ATOM RD300: Connected through RS-232/ RS-485

State

Buzzer

Power On

ON (1s)

Idle Online

OFF

Idle Offline/ Network Failure OFF

Degraded Mode

OFF

Содержание COSEC ATOM RD100

Страница 1: ...iciscreated suchasdesksmadeofplastics carpets Near volatile inflammable materials or inflammable goods such as drapes Wherevolatilegasand orinflammablegasiscreated Installing and servicing should be d...

Страница 2: ...m Know your ATOM 4 4 Know your ATOM What your Package Contains Things you will Need Technical Specifications LED and Buzzer Indications Connecting the Reader Installation 6 6 29 31 35 7 COSEC ATOM is...

Страница 3: ...it Cable Assembly Wall Mounting Accessories Flush Mounting Accessories with Type 1 and Type 2 only ATOM RD200MFM ATOM RD200MFI ATOM RD200SFM ATOM RD200SFI ATOM RD100KM ATOM RD100KI ATOM RD100M ATOM RD...

Страница 4: ...er Figure 9 for the same Step 1 Removing the Mounting Plate Figure 8 Figure 9 1 Installing the COSEC ATOM RD200 300 Wall Mounting Step 2 Connecting the Cables You can mount COSEC ATOM RD200 300 in two...

Страница 5: ...of the screws and screw grips through the holes A B and C Figure 11 9 3 Lead the cables from the wall through the drilled area D of the Mounting Plate as illustrated in Figure 12 Connect the necessar...

Страница 6: ...ot need to drill the area D Figure 13 3 Pull out the Cables from the Back Plate hole and lead the cables outside from the bottom opening of COSEC ATOM as illustrated in Figure 14 4 Connect the necessa...

Страница 7: ...ounting Plate align with each other Figure 15 Step 3 Inserting Mounting Screw 2 Slide the reader downwards to fix it into the groove of the Mounting Plate and insert the Mounting screw back in place a...

Страница 8: ...with the package and trace screw holes A B C and D on the surface where COSEC ATOM is to be installed see Figure 18 After tracing drill along the markings as shown in Figure 19 A B C D A B C D Figure...

Страница 9: ...Device Surface Mount Plate Figure 20 Step 3 To connect the cables refer below image for Concealed and Non concealed Wiring positions Cut out for Concealed Wiring Cut out for Non concealed Wiring 18 17...

Страница 10: ...ate on the installed Device see Figure 22 Figure 22 Front View Figure 21 A B C D Step 4 Affix the Surface Mount Plate with the Device on the surface with the help of the screws and screw grips through...

Страница 11: ...Figure 25 for the same Step 1 Removing the Mounting Plate Figure 23 Figure 24 Figure 25 3 Installing the COSEC ATOM RD100 Step 2 Connecting the Cables You can mount COSEC ATOM in two ways Concealed W...

Страница 12: ...f the screws and screw grips through the holes A and B Figure 27 23 3 Lead the cables from the wall through the drilled area C of the Mounting Plate as illustrated in Figure 24 Connect the necessary c...

Страница 13: ...need to drill the area C Figure 29 2 Unscrew the Back Plate screw with the help of screwdriver and remove the Back Plate 3 Pull out the Cables from the Back Plate hole and lead the cables outside fro...

Страница 14: ...ting Plate align with each other Figure 31 Step 3 Inserting Mounting Screw 2 Slide the reader downwards to fix it with the groove of the Mounting Plate and insert the mounting screw back in place on t...

Страница 15: ...55db at 10cm 9 14 VDC through main door controller or external power source Keypad Yes in ATOM RD100KM ATOM RD100KI Technical Specifications 29 30 Specification Parameters ATOM RD300 ATOM RD200 ATOM...

Страница 16: ...OFF 800ms ON 400ms OFF 800ms Alarm Critical Red ON till Reset ON till Reset 31 LED and Buzzer Indications 32 ATOM RD100 200 Connected through RS 232 RS 485 State Single LED tri color Buzzer Alarm Cle...

Страница 17: ...s 3 Cycles System Default ON till Reset Lost Connectivity with the ARC Controller OFF ATOM RD100 200 300 Connected through Wiegand Interface State Single LED tri color Buzzer Idle Blue ON 200ms OFF 22...

Страница 18: ...0 ESC ESC ENT ENT 35 36 RD TO 3 PARTY ACCESS CONTROL DEVICES COSEC ATOM Figure 37 GND Black RS232 TX Grey RS232 RX Pink TEMPER Light Blue W DATA1 White W DATA0 Green BEEPER Yellow RED LED Purple GREE...

Страница 19: ...t to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generate...

Отзывы: