background image

Built in Bluetooth

Tamper Detection

Yes BLE (4.0 and above)

Yes

-20°C to +55°C  

5% to 95% RH Non-condensing

Operating 
Temperature

Humidity

Buzzer

Yes

 (Tri Colour)

LED

User Capacity

Card Read Range

Reader Interface 
Type

RS-232, RS-485 
and Wiegand

Interface Support
Length

RS-232 (10ft), RS-485 (1200meter), 
Wiegand (150meter)

Input Power

**Type of Card

Credential Support PIN, RFID Card,

Mobile Credential
over BLE and 
Finger

-6 cm 

 MIFARE

R

 

MIFARE

R

/ Desfire / Combo Cards / NFC

HID I - class,

Yes (>55db at 10cm)

9-14 VDC through main door controller or external power 
source

Keypad

Yes 

(in ATOM RD100KM 
& ATOM RD100KI)

Technical Specifications

29

30

Specification 

Parameters

ATOM RD300

ATOM RD200

ATOM RD100

RFID Card,
Mobile Credential
over BLE and 
Finger

Card, Mobile 
Credential
over BLE

Depends on Master Device

or more, Desfire 
Ev1-Atleast 4 cm

-5 cm or more, 

 MIFARE

R

Desfire Ev1-Atleast 4 cm

RS-232, RS-485, WIFI and Wiegand

No

Yes 

(in Display)

No

ATOM RD300

ATOM RD200

ATOM RD100

Specification 

Parameters

0°C to +55°C  

** The type of Supported Card in COSEC ATOM is different as per their variants. 
Refer COSEC Server User Guide for the type of supported card in each variant.

Содержание COSEC ATOM RD100

Страница 1: ...iciscreated suchasdesksmadeofplastics carpets Near volatile inflammable materials or inflammable goods such as drapes Wherevolatilegasand orinflammablegasiscreated Installing and servicing should be d...

Страница 2: ...m Know your ATOM 4 4 Know your ATOM What your Package Contains Things you will Need Technical Specifications LED and Buzzer Indications Connecting the Reader Installation 6 6 29 31 35 7 COSEC ATOM is...

Страница 3: ...it Cable Assembly Wall Mounting Accessories Flush Mounting Accessories with Type 1 and Type 2 only ATOM RD200MFM ATOM RD200MFI ATOM RD200SFM ATOM RD200SFI ATOM RD100KM ATOM RD100KI ATOM RD100M ATOM RD...

Страница 4: ...er Figure 9 for the same Step 1 Removing the Mounting Plate Figure 8 Figure 9 1 Installing the COSEC ATOM RD200 300 Wall Mounting Step 2 Connecting the Cables You can mount COSEC ATOM RD200 300 in two...

Страница 5: ...of the screws and screw grips through the holes A B and C Figure 11 9 3 Lead the cables from the wall through the drilled area D of the Mounting Plate as illustrated in Figure 12 Connect the necessar...

Страница 6: ...ot need to drill the area D Figure 13 3 Pull out the Cables from the Back Plate hole and lead the cables outside from the bottom opening of COSEC ATOM as illustrated in Figure 14 4 Connect the necessa...

Страница 7: ...ounting Plate align with each other Figure 15 Step 3 Inserting Mounting Screw 2 Slide the reader downwards to fix it into the groove of the Mounting Plate and insert the Mounting screw back in place a...

Страница 8: ...with the package and trace screw holes A B C and D on the surface where COSEC ATOM is to be installed see Figure 18 After tracing drill along the markings as shown in Figure 19 A B C D A B C D Figure...

Страница 9: ...Device Surface Mount Plate Figure 20 Step 3 To connect the cables refer below image for Concealed and Non concealed Wiring positions Cut out for Concealed Wiring Cut out for Non concealed Wiring 18 17...

Страница 10: ...ate on the installed Device see Figure 22 Figure 22 Front View Figure 21 A B C D Step 4 Affix the Surface Mount Plate with the Device on the surface with the help of the screws and screw grips through...

Страница 11: ...Figure 25 for the same Step 1 Removing the Mounting Plate Figure 23 Figure 24 Figure 25 3 Installing the COSEC ATOM RD100 Step 2 Connecting the Cables You can mount COSEC ATOM in two ways Concealed W...

Страница 12: ...f the screws and screw grips through the holes A and B Figure 27 23 3 Lead the cables from the wall through the drilled area C of the Mounting Plate as illustrated in Figure 24 Connect the necessary c...

Страница 13: ...need to drill the area C Figure 29 2 Unscrew the Back Plate screw with the help of screwdriver and remove the Back Plate 3 Pull out the Cables from the Back Plate hole and lead the cables outside fro...

Страница 14: ...ting Plate align with each other Figure 31 Step 3 Inserting Mounting Screw 2 Slide the reader downwards to fix it with the groove of the Mounting Plate and insert the mounting screw back in place on t...

Страница 15: ...55db at 10cm 9 14 VDC through main door controller or external power source Keypad Yes in ATOM RD100KM ATOM RD100KI Technical Specifications 29 30 Specification Parameters ATOM RD300 ATOM RD200 ATOM...

Страница 16: ...OFF 800ms ON 400ms OFF 800ms Alarm Critical Red ON till Reset ON till Reset 31 LED and Buzzer Indications 32 ATOM RD100 200 Connected through RS 232 RS 485 State Single LED tri color Buzzer Alarm Cle...

Страница 17: ...s 3 Cycles System Default ON till Reset Lost Connectivity with the ARC Controller OFF ATOM RD100 200 300 Connected through Wiegand Interface State Single LED tri color Buzzer Idle Blue ON 200ms OFF 22...

Страница 18: ...0 ESC ESC ENT ENT 35 36 RD TO 3 PARTY ACCESS CONTROL DEVICES COSEC ATOM Figure 37 GND Black RS232 TX Grey RS232 RX Pink TEMPER Light Blue W DATA1 White W DATA0 Green BEEPER Yellow RED LED Purple GREE...

Страница 19: ...t to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generate...

Отзывы: