17.6
Working with trigger events
135
17.6
Working with trigger events
One or many trigger(s) can be used to control start of an acquisition, of a frame of an acquisition or each line of a
frame (for line scan devices). It can also be used to control the exposure duration at the beginning of a frame.
Typically, a trigger event has a
• falling edge and a
• rising edge.
A falling edge initializes the capture of a frame (see Figure 1).
Figure 1: Typical trigger events
There are three modes to use trigger events with mvHYPERION frame grabbers:
•
FrameStart
(p. 136)
•
Fram FrameStop
(p. 137)
•
Fram FrameStop (with restart option using the same event)
(p. 138)
The three modes will be described on the basis of a trigger event on J3.
Please open
"Setting -
>
Base -
>
Camera -
>
TriggerControls"
, where you can manage the mentioned trigger
events.