MSC-DE4832 Product Manual
Examples
>SysType
E01: Invalid command
>SysType
2
>
The first example command shows the response that would be received on a Carina series system with older
firmware not supporting the SysType command, the second example is what might be returned by an MSC-
GCP2U32 LCD panel.
3.11.46 Vars Command
Protocol Version: 2.3
Display all system configuration variables. Useful in serial terminal or telnet sessions to view all configuration
values.
Command
Description
Vars
Display all system configuration parameters. Note that variables
consisting of JSON data simply show the string JSON, to keep the
output concise. The output consists of one line per variable, with the
variable name followed by an equals '=' and then the value (not
quoted).
Examples
>Vars
DefaultProfile=1
DHCP=1
DNSPri=0.0.0.0
DNSSec=0.0.0.0
Firmware=1.5.1
Gateway=192.168.2.1
IP=192.168.2.80
Mac=00:00:00:00:00:00
MascotVer=2
MtxProfiles=JSON
Netmask=255.255.255.0
Profile=1
SerBaud=115200
SerProto=Mascot
SysName=MSC-Panel
SysType=2
>
The example above shows a typical output of the Vars command for an MSC-GCP2U32 LCD panel.
3.11.47 W Command
Routers and MSC-GCP2U32 only
Page 49 of 60