MSC-CP64X1E Product Manual

Baud 8N1 (8 data bits, No parity, 1 stop bit). Press ENTER to confirm the connection (a '>' prompt 
character should be displayed).  The software update command can then by typed in the serial 
connection window.

If you are unable to establish a Mascot command connection, use the 

Power On Software Update

 

method.

6. Type the Mascot command “B1” followed by ENTER, utilizing one of the above Mascot connection 

methods.

7. A few seconds after entering the above command, initiate the TFTP transfer (hit ENTER on the tftp 

command, etc), there is a 30 second time window to initiate the transfer.

8. If the transfer does not complete successfully within 30 seconds, retry from step 3.

4.2 Software failsafe recovery procedure

In the event the device software becomes inoperable and a regular software update cannot be performed, due to 
a failed software update or abnormal data corruption, this section can be consulted for the applicable software 
recovery procedure.  Prior to following this procedure, please check the following, in the event that the issue is 
not related to software functionality:

Ensure the proper power supply is being used and is connected to a good power source.

Check that applicable power indicators/panel buttons are lit and device hardware appears to be otherwise
in working order.

If network communication with the device is not working, ensure network cabling and interconnect 
hardware is functioning, ensure the proper IP address is being used to connect to the device, is unique on
the network, and that the system being used to connect to the device has a unique IP on the same 
network subnet.  Consult the 

Unknown IP address

 section for details on recovering from an unknown IP 

address.

After checking that these conditions are met, the following procedure can be used to recover from a corrupted 
firmware issue, depending on the system type.
Carina series systems require that the 

Power on Software Update

 procedure is used if the normal system 

firmware is unaccessible.  Please consult that section for additional details.

4.3 TFTP Software

There are many different options for TFTP client programs, the choice of which depends on what operating 
system you are using on the computer being used to perform the TFTP transfer from.  The following sections 
list some options for various operating systems.

4.3.1 Windows

Windows XP has a TFTP client installed and enabled by default.  For newer versions of Windows the TFTP 
client must be enabled using the following procedure:

1. Navigate to 

Start

 → 

Control Panel

 → 

Programs and Features

.

2. Click 

Turn Windows features on or off

 on the left side of the interface

3. Scroll to the 

TFTP Client

 option in the list and check the check box next to it.

4. Click 

OK

To use the tftp utility on Windows:

Page 50 of 55

© 2013-2018 Matrix Switch Corporation

www.matrixswitch

 

 corp.com

 

 

Содержание MSC-CP64X1E

Страница 1: ...Matrix Switch Corporation MSC CP64X1E Product Manual 2RU 64x1 Remote Elastomeric Button Panel Revision 1 8 Page 1 of 55 2013 2018 Matrix Switch Corporation www matrixswitchcorp com...

Страница 2: ...ALITY PERFORMANCE MERCHANTABILITY OR FITNESS FOR PURPOSE Matrix Switch Corporation disclaims all liability arising from this information and its use Use of Matrix Switch Corporation devices in life su...

Страница 3: ...commands and Panel GPIO commands Improved Software Update documentation Added pinouts for RS 232 and RS 485 serial port and GPIO Auxiliary interface Added XD series systems Revision 1 3 2016 05 17 Ad...

Страница 4: ...3 Button Panel Settings 13 2 3 Command Tab 13 3 Mascot Control Protocol 15 3 1 Protocol Changes 15 3 2 Telnet Access 16 3 3 Command Format 16 3 3 1 Command Names 17 3 4 Response Format 17 3 5 Command...

Страница 5: ...Names Command 38 3 10 33 PSub Command 39 3 10 34 PView Command 39 3 10 35 Reboot Command 40 3 10 36 ReclkDis Command 40 3 10 37 RemoteSync Command 40 3 10 38 S Command 41 3 10 39 SerBaud Command 41 3...

Страница 6: ...5 Troubleshooting 53 5 1 Unknown IP address 53 5 2 No Ethernet link when connected to network switch 53 5 3 Unexpected reboots 53 5 4 Glossary 53 6 Matrix Switch Corporation Warranty 55 Page 6 of 55 2...

Страница 7: ...power it up Once the device is powered it goes through the following startup sequence 5 second startup delay to allow for Power On Software Updates The remote panel will attempt to connect to the IP a...

Страница 8: ...connections In the event that the IP address of the device is unknown refer to the Unknown IP Address troubleshooting section 1 4 2 Network Settings Network settings can be changed on the Config tab...

Страница 9: ...IP packet routing between networks if on separate LANs SECURITY WARNING Matrix Switch Corporation devices are meant for installation in trusted LAN environments In the event that remote device config...

Страница 10: ...nations sources and or levels Example use scenarios Utilize an 8x1 remote panel to control a single destination of an 8x8 video router Use the local panel of a 16x16 two level Video and Audio router t...

Страница 11: ...lines to aid in further description below The web page interface for other router systems is sized appropriately Remote Panels show only the Config and Command tabs Numbered sections in Figure 1 1 Sys...

Страница 12: ...system up to 15 characters displayed at the top of the Web Page interface which is helpful when managing multiple systems 2 2 2 Network Settings WARNING DHCP should only be enabled or the IPAddress o...

Страница 13: ...stinations of a 16x4 Router 16 source 4 destination Another usage scenario would be to have 2 separate panels control different levels of a Video Audio Router Remote Router IP The IP address of the re...

Страница 14: ...text entry line followed by pressing the Enter key to execute them The results will be displayed in the text area below the command line Clicking the Clear Output button will clear all command output...

Страница 15: ...Corporation 3 1 Protocol Changes As new commands are added or other changes occur the MASCOT protocol version is incremented The protocol revision can be obtained using the MascotVer command Protocol...

Страница 16: ...mmand telnet 192 168 2 60 40 Pressing the ENTER key after successfully connecting should display the command prompt character 3 3 Command Format Commands consist of a command name zero or more argumen...

Страница 17: ...it decimal error code Table 4 shows possible error codes which may be returned in response to commands Error Message Description E01 Token too long A command name or string argument was too long E02 I...

Страница 18: ...rgument specified as 4 decimal numbers from 0 to 255 separated by periods Json String JSON formatted string the structure of which depends on the command The JSON string should be quoted in single quo...

Страница 19: ...parameter only Table 7 System Parameter Commands Parameter identifiers are represented as one or more alphanumeric words separated by periods representing a tree structure similar to file folders or...

Страница 20: ...S Network gateway address net ip IP RW S Network interface IP address net mac MAC R Network interface MAC address net netmask IP RW S Network interface mask pnl cmdEn Boolean RW AS Panel command macro...

Страница 21: ...uping command NetMask Netmask Network mask PairIO 0 1 I O pairing enable Superseded by the MtxGroup command PanelCmd Button Cmd Panel button GPIO command macros PanelCmdEn 0 1 Enable panel button GPIO...

Страница 22: ...ates section for details 3 10 2 C Command Routers and MSC GCP2U32 only NOTE Superseded by the MtxCfg Command The C command queries the matrix size The response is in the format Dests Srcs Levels Flags...

Страница 23: ...nd Gateway commands A value of 1 enables DHCP and will obtain the values for the IP address Netmask and Gateway from your DHCP server This value is saved and recalled on power up WARNING A DHCP server...

Страница 24: ...cho enable E 0 1 Set matrix echo enable 0 to disable 1 to enable Examples to query and then enable matrix echo E 0 E 1 3 10 6 Firmware Command NOTE Superseded by the sys firmware System Parameter Quer...

Страница 25: ...eter Table for a list of currently defined parameters This command supersedes many individual configuration commands NOTE This command queries Active values of parameters which may differ from values...

Страница 26: ...arameter identifier separated by an equals character and the value GetS Parameter Display the Stored value of a single parameter or a subset of parameters under a given parameter node 3 10 11 Help Com...

Страница 27: ...tection for outputs Format is one decimal number per output 0 Unlocked 1 SD 2 HD Example for a 16x4 system SD HD Unlocked Unlocked LockStatus 1 2 0 0 3 10 14 MAC Command NOTE Superseded by the net mac...

Страница 28: ...ination 2 on the second level The second example queries the mapping for a single destination The third example maps destination 1 to physical destination 5 on all levels The fourth example maps desti...

Страница 29: ...over what protocol version is in use The returned value is either an integer such as 2 or major and minor version numbers separated by a period such as 2 3 Example MascotVer 2 3 3 10 18 MtxCfg Command...

Страница 30: ...or reclocker disable If an argument is specified 0 7 then a more descriptive JSON structure is returned of the following form newlines and spaces added as a visual aid but are not necessarily part of...

Страница 31: ...to response as a visual aid MtxCfg7 version 1 status OK levels name Level1 type VIDEO destCount 4 srcCount 4 flags mute destNames Dest1 Dest2 Dest3 Dest4 srcNames Src1 Src2 Src3 Src4 state 1 2 3 4 pse...

Страница 32: ...assigning I O grouping MtxGroup 1 1 MtxGroup 2 4 MtxGroup 2 4 The first example MtxGroup command shows that I O grouping is disabled on both levels of a 2 level system The second command configures th...

Страница 33: ...preset information which is retained and available through system power cycles Command Description PAdd PRESET DEST SRC Add a connection of SRC to DEST on PRESET for all levels PAdd PRESET DEST SRC LE...

Страница 34: ...itch to ground Panel buttons and GPIO pins are specified by numeric ID Panel buttons are numbered beginning with ID number 1 Panel button order depends on the panel but generally has the top left butt...

Страница 35: ...ns 0 disable 1 enable Examples for querying and enabling panel command conditions PanelCmdEn 0 PanelCmdEn 1 3 10 26 PanelCond Command Protocol Version 3 0 Query and assign panel button GPIO status and...

Страница 36: ...he first example above queries the currently assigned panel GPIO conditions which shows that button number 1 and 2 have P0 and P1 conditions assigned respectively which lights the button LEDs when the...

Страница 37: ...setting 0 disabled The second command enables the external panel interface 3 10 29 PanelRate Command Protocol Version 2 1 For changing remote button panel refresh rate When a button panel is configur...

Страница 38: ...e insensitive value Mascot however additional control protocols may be added in the future Value is stored and recalled on power up Command Description ProtoSer Query the protocol used on the serial p...

Страница 39: ...PRESET DEST Remove any existing connection to DEST in PRESET for any level PSub PRESET DEST LEVEL Remove any existing connection to DEST LEVEL in PRESET Example PSub 1 2 PSub 1 3 2 The first command r...

Страница 40: ...y Protocol Version 2 1 Command for disabling or enabling SDI reclockers Not all router systems support this option Value is saved and recalled on power up Command Description ReclkDis Query current va...

Страница 41: ...ry destination are shown This command without an argument is equivalent to the X Command with no arguments If an argument value of 1 is supplied then the matrix state is displayed with labels The stat...

Страница 42: ...on the parameter and is defined in the System Parameter Table Values in Stored memory are loaded at system startup See System Parameters for more details Command Description Set List all parameter ide...

Страница 43: ...will not take effect until the system is restarted NOTE Some parameters may not be assignable in Stored memory for example if it does not make sense to recall a value on start up See System Parameters...

Страница 44: ...E Superseded by the sys name System Parameter Query or assign system name The system name is provided for convenience when managing multiple Matrix Switch Corporation systems This value is stored and...

Страница 45: ...mware not supporting the SysType command the second example is what might be returned by an MSC GCP2U32 LCD panel 3 10 46 Vars Command Protocol Version 2 3 Display all system configuration variables U...

Страница 46: ...PRESET Example to save state to preset 1 W 1 3 10 48 WebPass Command Assign a web password to password protect the web page interface The serial and TCP IP port Mascot protocol control is not protect...

Страница 47: ...a destination if supported for a given level Examples X 1 1 2 2 3 8 0 4 X 3 3 8 X 3 4 X 4 0 2 In the above examples the first command queries the matrix routing state typical of a 16x4 system for exam...

Страница 48: ...a fixed update IP address of 192 168 2 59 whereas CSU uses the device s configured IP address POSU should be available even if a device s firmware gets corrupted from a previous update attempt whereas...

Страница 49: ...is an Ethernet switch between the device and update PC Steps for executing a Command Software Update 1 Ensure that the Software Update Requirements are met 2 Configure the PC for a unique IP address o...

Страница 50: ...k communication with the device is not working ensure network cabling and interconnect hardware is functioning ensure the proper IP address is being used to connect to the device is unique on the netw...

Страница 51: ...y at Users your_user_name 2 Open a terminal Applications Utility Terminal 3 Use cd commands to change to the location of the firmware file for example cd Users your_user_name followed by the ENTER key...

Страница 52: ...use the device s configured IP if the update method being used utilizes the devices IP address tftp 192 168 2 59 5 Execute the following commands from within the tftp program pressing ENTER after eac...

Страница 53: ...e cable for a known good cable 2 Ensure proper power supply is being used for the system 5 VDC 2 Amp 3 If the switch is a managed switch try forcing 10 BaseT for the Ethernet port the device is connec...

Страница 54: ...Router A Video Audio Routing device routes one or more sources to one or more destinations not to be confused with a Network router which is referred to as a Network Switch in this manual Simple Pane...

Страница 55: ...hich shall be placed on the outside of the shipping package 6 This warranty does not apply if the product has been damaged by accident abuse misuse misapplication or modification EXCEPT AS SET FORTH A...

Отзывы: