background image

11

 

MOP-TFT480272-43A-BLM-TPC

 

 

11

 

Inspection Criterion 

11.1

 

Description 

This specification is made to be used as the standard acceptance/rejection criteria for the 
MOP-TFT480272-43A-BLM-TPC. 
 

11.2

 

Sample plan 

Sampling plan according to GB/T2828.1-2003/ISO 2859-1: 1999 and ANSI/ASQC Z1.4-1993, normal level 2 and 
based on: 
Major defect: AQL 0.65 
Minor defect: AQL 1.5 

 

11.3

 

Inspection condition 

 

Viewing distance for cosmetic inspection is about 30±5cm with bare eyes, and under a 600~1000lux 
environment for visual inspection and 0~200lux for function test. All directions for inspecting the sample 
should be within 45°against perpendicular line. (Normal temperature 18

28

C and normal humidity 

60

15

RH). 

 

 

During testing, the LCD is driven using the voltage level (Within 

0.5V of the typical value at 25

C.) that 

provides the most optical contrast   

 

11.4

 

Definition of inspection zone in LCD 

 

Figure 7: Inspection Zones in an LCD 

Zone A: character/Digit area 
Zone B: viewing area except Zone A (ZoneA + ZoneB=minimum Viewing area) 
Zone C: Outside viewing area (invisible area after assembly in customer’s product) 
 

*Note:

 As a general rule, visual defects in Zone C are permissible, if it does not affect display quality and assembly of 

customer’s product 
 

11.5

 

Function Defect 

Items to be inspected 

Inspection criterion 

Classification of defects 

All functional defects 

1) No display 
2) Display abnormally   
3) Missing vertical, horizontal segment   
4) Short circuit 
5) Back-light no lighting, flickering and abnormal lighting. 
6) obvious striation 
7) Current beyond specification value   

MA 

Missing   

Missing component 

Outline dimension 

Overall outline dimension exceed the drawing is not allowed. 

 

B  C 

Содержание MOP-TFT480272-43A-BLM-TPC

Страница 1: ...MOP TFT480272 43A BLM TPC Hardware Manual Revision 1 0...

Страница 2: ...1 MOP TFT480272 43A BLM TPC Revision History Revision Date Description Author 1 0 May 26 2017 Initial Release Divino...

Страница 3: ...ming 9 10 Power Sequence 10 10 1 Power Up Sequence 10 10 2 Power Down Sequence 10 11 Inspection Criterion 11 11 1 Description 11 11 2 Sample plan 11 11 3 Inspection condition 11 11 4 Definition of ins...

Страница 4: ...ics DC Characteristics at Ta 25 C Item Symbol Min Typ Max Unit Power Supply Input Voltage VDD 3 0 3 3 3 6 V I O logic voltage VDDIO 1 8 3 3 V Input voltage H level VIH 0 7VDD VDD V Input voltage L lev...

Страница 5: ...iption IC solution on TP Model GT911 Touch Count Max 5 point Display Resolution 480 272 Interface Type I2C I2C Slave Address 0x5D Origin of Coordinate Top left corner Parameter Min Typ Max Unit Interf...

Страница 6: ...5 MOP TFT480272 43A BLM TPC 6 External Dimensions Figure 1 MOP TFT480272 43A BLM TPC Drawing...

Страница 7: ...te 5 Definition of color chromaticity CIE1931 CIE x y chromaticity the x y value is determined by screen active area center position P5 Note 6 Definition of Viewing angle Viewing angle is the angle at...

Страница 8: ...I Red data 13 20 Green 0 7 I Green data 21 28 Blue 0 7 I Blue data 29 GND I Ground 30 PCLK I Dot clock signal 31 DISP I Display on off 32 HSYNC I Horizontal sync input 33 VSYNC I Vertical sync input 3...

Страница 9: ...Clock rising time Trck 9 ns Clock falling time Tfck 9 ns HSD width Thwh 1 DCLK HSD period time Th 55 60 65 s HSD setup time Thsu 12 ns HSD hold time Thhd 12 ns VSD width Tvwh 1 Th VSD setup time Tvsu...

Страница 10: ...rameter Symbol Value Unit Min Typ Max DCLK frequency fclk 5 9 12 MHz VSD period time Tv 277 288 400 H VSD display area Tvd 272 H VSD back porch Tvb 3 8 31 H VSD front porch Tvfp 2 8 97 H HSD period ti...

Страница 11: ...MOP TFT480272 43A BLM TPC 10 10 Power Sequence 10 1 Power Up Sequence Figure 5 Power On Sequence 10 2 Power Down Sequence Figure 6 Power Off Sequence...

Страница 12: ...using the voltage level Within 0 5V of the typical value at 25 C that provides the most optical contrast 11 4 Definition of inspection zone in LCD Figure 7 Inspection Zones in an LCD Zone A character...

Страница 13: ...D a b 2 0 1 D 0 2 4 0 2 D 0 3 0 0 3 D 0 5 0 D 0 5 0 the distance between the two defect dot DS 5mm line defect Length mm Width mm Judgement Criterion disregard W 0 05 allowed L 5 0 05 W 0 1 4 L 5 W 0...

Страница 14: ...unused input terminal to VDD or VSS Do not input any signals before power is turned on Ground your body work assembly areas and assembly equipment to protect against static electricity 12 4 Packing T...

Страница 15: ...the display in a polyethylene bag with the opening sealed Ensure that nothing is making contact with the polarizer surface It is recommended to store them in the same packaging that was provided upon...

Страница 16: ...ur Hundred Eighty Pixel Columns 4 Display Rows 272 Two Hundred Seventy Two Pixel Rows 5 Display Size 43 4 3 6 Display Form Factor A A Form Factor 7 Brightness Level BLS Brightness 300 Nit BLM 300 Nit...

Страница 17: ...N AN20 OAI 80038AA 2008 A 315 U004B15300 UMSH 8596MD 34T REV D 98 0003 3490 8 1044278 1029309 1060549 DE 127 TU 30 7 5 DE 128 TU 20 7 5 EP LK007TFTPCAP FR7 0A00 RC2002A TIG CSX NL6448BC2021C TX14D23VM...

Отзывы: