9.9 MOTOR REPLACEMENT - CONTINUED
7) Disconnect the motor cable ground wire from the grounding post (Figure E).
8) Disconnect the motor cable from the MCB (Figure F).
9) Remove the 4 screws holding the motor to the frame (Figure G).
10) Remove the motor from the treadmill.
11) Reverse Steps 1-10 to install a new motor.
NOTE:
Be sure that the motor isolator pad is in place prior to mounting the new motor (Figure
H).
12) Test the treadmill for function as outlined in Section 9.21.