14
6.1 USING ENGINEERING MODE
1) To enter Engineering Mode, press & hold the INCLINE DOWN and
SPEED DOWN keys at the same time for 3-5 seconds until Manager
appears on the display.
2) Press the INCLINE or SPEED keys until Engineering appears on
the display (Figure A) and press ENTER.
3) To scroll between settings in the Engineering Mode, press the
INCLINE or SPEED keys.
4) Press ENTER to modify the settings once displayed.
5) Press any INCLINE or SPEED key to change the value of the set-
ting.
6) Once the setting is correct, press ENTER to save.
7) Press the EMERGENCY STOP to exit Engineering Mode..
FIGURE A
6.2 ENGINEERING MODE OVERVIEW
CUSTOM SETTING
DEFAULT
MINIMUM
MAXIMUM
UNIT
DESCRIPTION
Disable Errors
OFF
OFF
ON
N/A
Off - Shows A-C class errors. On - Shows C class
errors only.
Elevation Minimum
28
20
239
N/A
Controls the low incline parameter.
Elevation Maximum 230
20
239
N/A
Controls the high incline parameter.
Auto Calibration
N/A
N/A
N/A
N/A
This function is to calibrate the treadmill incline.
Speed Units
MILE
MILE
KILOMETER
DISTANCE
Measurement unit used for calorie calculations,
distance, and speed.
Pause Time
30 SECONDS 5 SECONDS 10 MINUTES
SECOND /
MINUTE
Controls the maximum time the treadmill can be
paused during a workout.
Serial Number
N/A
N/A
N/A
N/A
Serial Number input is available for both the Console
and Frame. Due to the limited LED characters, 2 layers
are used to enter the serial number. First Layer:
- PPPPP V
- PPPPP is the product name
- V is the version. If the version is A, just leave this
blank.
Second Layer
- YY MM nnnnn.
- YY is the year (11, 12).
- MM is the month (e.g. 08, 09, 10).
- nnnnn is the actual serial number.
Use the UP / DOWN LEVEL keys to navigate the
layers and the number keys to input the serial number.
The product name is dependent on the Machine Type
setting.
For example, the console is TM507 with ver. C and the
manufactured date is 2011.08 with 98765. The frame
is TM507 with ver. C and the manufactured date is
2011.06 with 12345. Their serial numbers are:
Console SN: TM507C 1rst layer, 110898765 2nd layer.
Frame SN: TM507C 1rst layer, 110612345 2nd layer.
Reset Defaults
N/A
N/A
N/A
N/A
Reset the default values to factory settings.
Club ID
N/A
N/A
N/A
N/A
This sets the club ID for clubs using Asset
Management.
CHAPTER 6: ENGINEERING MODE
Содержание T1X-03AC
Страница 1: ...T 1 X 0 3 A C T R E A D M I L L S E R V I C E M A N U A L...
Страница 4: ...1 1 1 SERIAL NUMBER LOCATION CHAPTER 1 SERIAL NUMBER LOCATION...
Страница 19: ...16 8 1 ELECTRICAL DIAGRAMS CHAPTER 8 TROUBLESHOOTING...
Страница 21: ...18 8 1 ELECTRICAL DIAGRAMS CONTINUED PULSE GRIP CONNECTING WIRE N70 CHAPTER 8 TROUBLESHOOTING...
Страница 75: ...72 NOTES...