10
How to enter into the engineering mode?
1.
Press & Hold both “DOWN” and “UP”
at the same time for 3-5 sec. Then, the
dot vision display will show
“MANAGER”
2. Press the " UP or DOWN" to select you
want and press the “SELECT" key enter.
To Store up the parameter
START
Clean accumulate time and distance
Hold MANUAL & RANDOM for 3’S
Enter address
SELECT
Select address or decrease parameter
DOWN
Select address or add parameter
UP
function
key name
Engineer mode interpret
Test for factory
ENG 1
HR test
SERVICE 4
Show accumulate distance & time
SERVICE 3
HW test mode show RPM
SERVICE 2
Display test
SERVICE 1
Select address or add parameter
MANAGER
Function interpret
Display show