58
CHAPTER 9: PART REPLACEMENT GUIDE
9.18 CONTROL ZONE SENSOR REPLACEMENT
1) Turn off power and disconnect the cord from the machine.
2) Pull up on the Control Zone carefully (Figure A).
3) Unplug the wire connector from the Control Zone and remove the Control Zone from the unit (Figure B).
4) Remove the 8 screws to disassemble the Control Zone sensor from the Control Zone (Figure C), then remove the Control Zone sensor.
5) Reverse Steps 1-4 to install a new Control Zone sensor.
6) Test the Climb Mill for function as outlined in Section 9.20.