MTS600 Instruction Manual
52
8. Data communication
The measurement data of JOB stored in memory of
instrument can be transferred to a PC, and the known
coordinate data also can be transferred from PC to the
internal memory of instrument.
Press [MENU] key on the panel after power on to
enter main menu, then select "F3-Communication" to enter data communication
mode.
8.1 Settings of communication
l
MTS-600 serial communication protocol: 8 data bit,1 stop bit, none
parity ,baud rate 1200
、
2400
、
4800
、
9600
、
19200 bps optional (default 9600
bps).
l
Before starting communication with PC, please insure the parameters of
communication of each other are set correctly and the same, otherwise the
communication will be failed.
Follow steps below, the communication baud rate can be changed:
Example: Set baud rate as
“
4800 bps
”
①
Press [F3] to select "Comms setting" in
<Communication> menu. The current setting is
displayed.
②
Press [F5] to entered the first page of <Comms
Setting> menu.
Communication
F1-Send data
F2-Receive data
F3-Comms. setting
Comms. Setting <2/2>
⊙
F1--9600 bps
○
F2--19200 bps
Comms. Setting <1/2>
○
F1--1200 bps
○
F2--2400 bps
○
F3--4800 bps