MTS600 Instruction Manual
43
6.7 Measure and record data in basic measurement mode by pressing one key
For the convenience of users, there is a [USER] key on the panel of MTS-600,
whose function can be defined by user (Please see "10.3 define function of the
USER key"), default function is set as "measure and record data" by factory, the
following explain how to measure and record data quickly by press [USER] key in
basic measurement mode.
①
In basic measurement mode, collimate the target
point
.
②
Press [USER] key, begin measuring the target point.
③
When measuring finished, point number of the
target and name of the current JOB will be displayed
2 seconds, then a short beep will sound, the measured
data is stored in the memory automatically.
if pressing [EDIT] on this screen in 2 seconds, it is
possible to edit the point number, code, prism height and select another JOB.
Please see "6.4 recode measurement data".
④
Point number will add one automatically, continue
to measure the next point.
H.dist 165.274m
V.ang(
Z
) 92
°
55
′
39
″
H.ang(
R
) 90
°
15
′
00
″
MEAS
DISP
MODE
EDM
OUTP
Psm.const -30
Atmos. crn 0ppm
Meas. mode Fine R
STOP
Measure & Record Data
PT# PT-001
Current JOB <MYJOB>
EDIT
H.dist 165.274m
V.ang(
Z
) 92
°
55
′
39
″
H.ANG(
R
) 90
°
15
′
00
″
MEAS
DISP
NODE
EDM
OUTP