background image

Operating manual  

EP55 / EP140 

MATO 

GmbH & Co. KG

 / Benzstr. 16-24 / 63165 Mühlheim a. Main / Tel:+49(0)6108-906-0 / Fax:+49(0)6108-906-120 

 

14

Tips for fault diagnostics 

Symptom 

Possible cause 

Rectification 

Device does not 
discharge any oil. 

The container is empty. 
The oil supply has been interrupted. 
Faulty pump. 

Check the level of the container. 
Prime the pump, check the supply line. 
Replace pump. 

Device is 
producing too 
little oil. 

Suction screen is clogged. 
Filter in the handle of the nozzle is 
clogged. 

Clean suction screen. 
Clean filter. 

 
 

Specifications 

 
 
 
 

Type 

EP 55 

EP 140 

Power requirements 

220/230V 

50Hz – 4A  

220/230V 

50Hz - 5A  

Engine performance 

0.46 KW 

0.5 KW 

Protection rating 

IP 55 

IP 55 

Security of the supply line 

10A 

10A 

max. delivery pressure 

2 bar 

2,8 bar 

max. delivery rate 

at open discharge without accessories 

55 l/min. 

80 l/min. 

Volume level 

ca. 67 

dB(A)

 

Dimensions L x W x H

 

240x120x190 

230x180x190 

Weight 

 

Unit without accessories 

7 kg 

8,6 kg 

Fluid media: 

Diesel, light fuel oil 
Fluids including Hazard Class A3 can be supported. 
Viscous media of Hazard Classes A1 and A2 can 

not 

be supported. 

If media not listed here is used, please clarify this with our technical department. 

 

Disposal

 

 

 

After termination of use the device is to be disposed of in an environmentally  

 

 

friendly manner in accordance with applicable statutory provisions. 

 

 

Oil-tainted parts do not belong in the dustbin! 

 

 

 

The applicable regulations for the registration, installation and operation of 

equipment for handling of substances hazardous to water are to be strictly observed by the 
operator (such as, e.g., Federal Water Act, German Ordinance on Exposure to Substances 
Hazardous to Waters and Technical Rules and Regulations for Flammable Liquids). 

 

Содержание EP 140

Страница 1: ...Betriebsanleitung Operating Instructions Mode d emploi Instrucciones de empleo Instrucciones de empleo MATO GmbH Co KG Benzstr 16 24 63165 M hlheim a Main Tel 49 0 6108 906 0 Fax 49 0 6108 906 120 Ers...

Страница 2: ...g Operating manual Mode d emploi Instrucciones de uso EP55 EP140 MATO GmbH Co KG Benzstr 16 24 63165 M hlheim a Main Tel 49 0 6108 906 0 Fax 49 0 6108 906 120 2 Deutsch 3 8 English 9 14 Fran ais 15 20...

Страница 3: ...enst tze 4 2 5m Anschlusskabel mit Netzstecker 5 4m oder 8m gewebeverst rkter Abgabeschlauch DN 20 mit AG R 6 Pistolenhalter 7 Anschluss R3 4 8 Filtersieb 9 R 2 und M 64x4 Fassadapter 10 Ein Ausschalt...

Страница 4: ...atik Zapfpistole mit Drehgelenk mit AG R 1 2 R 2 und M 64x4 Fassadapter 3 2 m gewebeverst rkter Ansaugschlauch DN 25 4 Fu ventil mit Ansaugfilter 5 4m oder 8m gewebeverst rkter Abgabeschlauch DN 25 mi...

Страница 5: ...verwenden um labsp lungen auf den Boden zu verhindern Arbeitsbereich st ndig sauber und lfrei halten Hinweise vorbereitende Ma nahmen Handhabung F r eingesetzte Gefahrstoffe z B Diesel Heiz l Sicherh...

Страница 6: ...nten ist auf Seite 3 f r die Anlagen EP 55 S und EP 55 AZ auf Seite 4 f r die Anlage EP 140 abgebildet Bei anstehender Spannung und eingeschalteter Anlage beginnt die Fl gelzellenpumpe zu laufen Der L...

Страница 7: ...tshinweise beachten 5 Wartung und Pflege Wartungs Inspektions und Reparaturarbeiten d rfen nur von qualifiziertem Fachpersonal aus gef hrt werden Vor jeder Reparatur oder Wartungsarbeit Stromversorgun...

Страница 8: ...uck 2 bar 2 8 bar max F rdermenge bei freiem Auslauf ohne Zubeh 55 l min 80 l min Lautst rke ca 67 dB A Abmessungen L x B x H 240x120x190 230x180x190 Gewicht Aggregat ohne Zubeh r 7 kg 8 6 kg F rderme...

Страница 9: ...3 Pump support 4 2 5m connection cable with mains plug 5 4m or 8m fabric reinforced discharge hose DN 20 with AG R 6 Gun holder 7 Connection R3 4 8 Filter screen 9 R 2 and M 64x4 Barrel Adapter 10 On...

Страница 10: ...utomatic nozzle with pivot hinge with AG R 1 2 R 2 and M 64x4 Barrel Adapter 3 2 m fabric reinforced suction hose DN 25 4 Pedal valve with suction filter 5 4m or 8m fabric reinforced discharge hose DN...

Страница 11: ...use vane cell pump in the rain Always keep the work area clean and free of oil Instructions for preliminary actions handling Observe safety data sheets for hazardous substances e g diesel fuel oil us...

Страница 12: ...ual components for the systems EP 55 S andEP 55 AZ is pictured on page 3 and on 4 for system EP 140 When the voltage is ready and the system is switched on the vane cell pump will begin to run The sco...

Страница 13: ...and care Maintenance inspection and repair work must only be performed by qualified personnel Before carrying out any repair or maintenance work break off the power supply unplug mains plug and relie...

Страница 14: ...delivery rate at open discharge without accessories 55 l min 80 l min Volume level ca 67 dB A Dimensions L x W x H 240x120x190 230x180x190 Weight Unit without accessories 7 kg 8 6 kg Fluid media Dies...

Страница 15: ...ec fiche secteur 5 Tuyau de distribution 4 m ou 8 m gaine renforc e LN 20 avec 19 05 mm AG 6 Support de pompe 7 Raccord 19 05 mm 8 Passoire du filtre 9 Adaptateur profil 50 8 mm et M 64 x 4 10 Bouton...

Страница 16: ...oto de de 25 40 mm 2 Adaptateur profil 50 80 mm M 64 x 4 3 Tuyau d aspiration gaine renforc e 2 m LN 25 4 Soupape de pied avec filtre d aspiration 5 Tuyau de distribution 4 m ou 8 m gaine renforc e LN...

Страница 17: ...ment le poste de travail veillez ce qu il n y ait pas d huile Conseils sur les mesures pr liminaires manipulation Observez les fiches de s curit respectives aux mati res dangereuses utilis es comme di...

Страница 18: ...pris les composants individuels est repr sent e page 3 pour les dispositifs EP 55 S et EP 55 AZ et page 4 pour le dispositif EP 140 Sous pr sence de tension et dispositif allum la pompe palettes comme...

Страница 19: ...ls de s curit 5 Maintenance et entretien Seul le personnel qualifi est habilit effectuer les r visions inspections r parations Avant chaque r paration ou r vision coupez l alimentation en courant d br...

Страница 20: ...accessoires 55 l min 80 l min Niveau sonore ca 67 db A Dimensions L x l x h 240x120x190 230x180x190 Poids Moteur sans accessoires 7 kg 8 6 kg Fluides d alimentation Diesel mazout Sont autoris s les f...

Страница 21: ...de conexi n con enchufe de alimentaci n 5 4 m 8 m de manguera de salida reforzada DN 20 con AG R 6 Soporte de pistola 7 Conexi n R3 4 8 Filtro 9 R 2 y M 64x4 adaptador de tonel 10 Interruptor encendid...

Страница 22: ...con bisagra con AG R 1 2 R 2 y M 64x4 adaptador de tonel 3 2 m de manguera de salida reforzada DN 25 4 V lvula de retenci n con filtro de aspiraci n 5 4 m 8 m de manguera de salida reforzada DN 25 co...

Страница 23: ...eite el rea de trabajo Consejos para tomar medidas Aplicaci n Tenga en cuenta las indicaciones de las hojas de seguridad cuando utilice sustancias peligrosas gas leo gasol leo Durante su uso debe llev...

Страница 24: ...p gina 3 y en la p gina 4 aparece el dispositivo EP 140 La bomba de paletas empieza a funcionar cuando est conectada a la corriente y el dispositivo est encendido La extensi n de la entrega queda pate...

Страница 25: ...to Las operaciones de mantenimiento inspecci n y reparaci n solo se llevar n a cabo por parte de personal cualificado Cortar la corriente antes de cada reparaci n u operaci n de mantenimiento desenchu...

Страница 26: ...Intensidad de sonido aprox 67 dB A Dimensiones L x A x F 240x120x190 230x180x190 Peso Grupo sin accesorios 7 kg 8 6 kg Productos bombeados Gas leo fuel leo ligero Tambi n se bombean productos de bombe...

Страница 27: ...inentes regulaciones EG Maschinen Richtlinie 2006 42 EG EG Richtlinie EMV 2004 108 EG Angewendete harmonisierte europ ische Normen Harmonised European standards applied Suivant les normes europ ennes...

Страница 28: ...KG www mato de Tel 49 0 6108 906 0 Benzstr 16 24 D 63165 M hlheim a M mato germany mato de Fax 49 0 6108 906 120 Qualit tsschmierger te High Quality Fluid Handling Products La Technologe de graissage...

Отзывы: