Operating instructions
eHybrid-Greaser
MATO
GmbH & Co. KG
/ Benzstr. 16-24 / 63165 Mühlheim a. Main / Tel: +49(0)6108-906-0 / Fax :+49(0)6108-906-120
-
Caution: Do not run the pump against the closed gun for longer than 3 min.
-
Please note that the gear pump and the high-pressure piston pump will heat up.
-
To avoid unnecessary heating of the unit, switch off the gear pump immediately after completing
the lubrication process(es).
Observe the safety instructions.
5
Maintenance and care:
Regularly check the pressure-carrying parts (pressure hose and grease gun) as well as the
current-carrying parts of the pump for any possible damage or wear. Immediately replace any
defective parts with original parts.I
Ordering spare parts:
The following information is required when ordering spare parts:
Type, designation of the ET, order number.
The following maintenance intervals must be observed to ensure trouble-free operation
Before each use
annually
According to
manufacturer
High-pressure grease gun
X
X
High-pressure armoured hose
X
X
X
Hydraulic hose lines
X
X
X
High-pressure grease gun
X
X
Testing of portable
electrotechnical consumers
½ yearly
X
Check for any loose connections
X
Readability and presence of
information
X
6
Indications in case of malfunctions:
Symptom
Possible cause
Remedy
The motor of the
hydraulic gear pump does
not run.
Mains plug not in socket.
The wiring to the motor is
defective.
Insert the mains plug into the socket.
Repair by a qualified electrician.
Pump does not deliver
grease.
The container is empty.
The grease supply is
interrupted.
Suction strainer is dirty
Check the filling level in the container.
Bleed the pump.
Clean suction strainer
Unit continuously stops
pumping.
Suction strainer is clogged.
Clean the suction strainer.
Attention!
When dismantling the nut, only hold it in the area (20mm) directly behind the washer.
11
Suction
Washer
Nut
20mm
Содержание eHybrid-Greaser 230V
Страница 25: ...25...