Jaws can be used in
either direction for
outward clamping
Left pusher and external hex of
leadscrew go on the “L” side of vise
Hook feature
REVERSE FORCE CLAMPING SETUP
To switch from inward clamping to reverse force clamping:
1. Remove the pushers from the leadscrew
2. Keeping each pusher on the end it was removed from, rotate each pusher so that the top hook feature faces away from the vise center
3. Thread the pushers simultaneously back onto the leadscrew
4. Install the jaws in desired orientation
5. Center the jaws per the vise calibration procedure (see instructions)