MAXIMUS2.0
User's Manual
33
If JIS is selected, tap
, the system will enter Select testing
capacity screen. Users can select corresponding standard capacity
value according to battery model marked on battery.
Tap
7.
and the testing result will appear on the following screen.
Fig. 7-7
2. Charging system and starting system test
While performing this test, the battery’s charging voltage value
and starting voltage can be obtained in case of engine starting and
accelerating. Based on the data, the system will judge whether
battery’s charging and actuation status is normal or not.
Tap
in Fig. 7-7, a dialog box will pop up as Fig. 7-8.
Fig. 7-8
After detecting engine starting, follow the instructions on the screen to
increase the speed.
The system begins to receive test data information after acceleration
was detected, as shown in Fig. 7-9.
Fig. 7-9
Tap [OK], test data will be shown on the screen, similar to Fig. 7-10.
Fig. 7-10
Notes: It is unnecessary to perform charging system and start
system test after fi nishing battery test, but battery test must be done
before undergoing charging system and starting system test.
7.4.3 Outside the vehicle test
It only applies to battery test and detecting
fl
oating electricity will be
ignored while performing battery test.
On Fig. 7-4, tap [Outside the vehicle] to select battery test standard.
Содержание MAXIMUS2.0
Страница 1: ...Version V1 00 000 Revised date 02 10 2014...