background image

12

Instructions for use of attachments: Desktop Chargers 4-814/4-816

Version: 28.04.2008

1. Main switch/pilot lamp  <=> 

Switch is alight when the charger is ON

2. Charge indicator lamp  <=>   

Glows steady red when a depleted RECHARGEABLE BATTERY 4-809/4-810 is being charged 

2. Charge indicator lamp  <=> 

Glows green when RECHARGEABLE BATTERY 4-809/4-810 is fully charged

3. Charging compartment  <=> 

For inserting the RECHARGEABLE BATTERY 4-809/4-810 in the direction indicated by the arrow

4. Battery 

<=> 

Rechargeable battery 4-809/4-810

Preparing for use: 

Step 1.  Plug in power plug at the socket; switch on at main switch

 (1)

; triple-function lamp

 (2)

 glows red ( see description in Step 

3)

.

Step 2.  Insert RECHARGEABLE BATTERY 4-809 or 4-810 (4) into the charging compartment 

(3)

 in the direction of the arrow.

Step 3.  The charge indicator lamp 

(2) 

must first flash red for 20 seconds if the BATTERY 4-809/4-810 is depleted. After approx. 

20 seconds, it glows steady red to indicate that the battery is being charged. When the battery is fully charged, the lamp changes 

to green. 

(4) 

The charging time for a depleted BATTERY 4-809/4-810 

(4)

 is approx. 60 minutes. The lamp glows green to indicate 

when charging is complete. During charging, the Charger 4-814/4-816 and the BATTERY 4-809/4-810 warm up, but this does not 

indicate a fault. As soon as the BATTERY 4-809/4-810 is fully charged, the lamp glows green 

(2)

 Chargers 4-814 and 4-816 switch 

off automatically when the BATTERY 4-809/4-810 is fully charged. This means that you can leave the BATTERY 4-809/4-810 in the 

operational Charger 4-814/4-816 for a prolonged period so that it is always charged to full capacity without any risk of overcharging  

The BATTERY 4-810 should be checked and recharged before use!

Fault:

 

After inserting BATTERY 4-809/4-810 

(4)

 in the charging compartment 

(3)

, the charge indicator lamp 

(2)

 on the Charger 4-814/4-816 

fails to light up.

FAULT RECTIFICATION:

 

Turn the 

BATTERY 4-809/4-810 

(4)

 slyghtly in the charging compartment 

(3)

, the charge indicator lamp 

(2)

 on the Charger 4-814/4-816 

fails to light up.

NOTE AND WARNING:

if there is a power fialure, neither of the pilot lamps (1) amd (2) will glow.

Chargers 4-814/4-816 and BATTERIES 4-809/4-810 are not medical devices, and therefore should only be used in closed 

rooms outside the operating theatre. Only use in rooms that are free of dust and moisture.

IMPORTANT: SAFETY INSTRUCTION!  

Only store in the original packaging, in a dry, closed room. Never sterilise the BATTERY 4-809/4-810 or the Charger 

4-814/4-816. Only use compatible BATTERIES 4-809 and 4-810 from MAT GmbH&Co.KG. Combination with other makes is 

forbidden. Do not immerse Charger 4-814/4-816 or BATTERY 4-809/4-810 in liquid.

1

2

3

4

Содержание 4-807

Страница 1: ...LOGY CORDLESS DRILL SYSTEM User s Manual No 6 1 GB CORDLESS SYSTEM Easy to use Ergonomic design Simple compact battery packs with high capacity Small robust drill with an extensive range of attachments Steam sterilisable 1253 ...

Страница 2: ...nitely variable clockwise rotation For infinitely variable reverse rotation hold down both triggers R and L Specifically reverse rotation is required for rocedures such as releasing bone screws and removing Kirschner wires Reverse rotation must be used exclusively for the above mentioned procedures Note The Rechargeable Battery 4 810 does not require sterilisation but must be treated with the same...

Страница 3: ... intervention to destroy microorganisms Today health professionals and patients are at constantly increasing risk so appropriate cleaning and disinfection of these drills and attachments is extremely important If in doubt contact MAT GmbH Co KG and the manufacturer of the disinfectant and cleaning agent used Note Please observe the Instructions for use of attachments with the exception of the Rech...

Страница 4: ...m MAT GmbH Co KG may be used for repairs The operator is required to obtain a list detailing the type and scope of work performed with the company stamp date and signature of the repairer SERVICING We recommend sending the Cordless Drill 4 807 to MAT GmbH Co KG for servicing after a year or after 120 sterilisation cycles surgical operations WARNING All equipment must be cleaned and sterilised befo...

Страница 5: ...Risk analysis evaluation of risk analysis Evaluation of the check list of Fundamental Requirements for this medical device Attachments Description Order of Number REF Cordless Drill with end cap 4 807 Medical Device Mono Block Battery oscillating Saw 4 808 Medical device Long rechargeable battery with extension 4 809 Medical device Standard rechargeable battery 4 810 Medical device Funnel for inse...

Страница 6: ... with the provisions of MED UMW MAT GmbH co KG will deal with disposal Symbol description R clockwise rotation L reverse rotation Symbol 1 Observe instructions in User s Manual Symbol 2 Classification Type BF Symbol 3 Recyclable Symbol 4 CE 1253 in accordance with Directive 93 42 EEC Symbol 5 Protection class II device Key to the symbols ...

Страница 7: ...w at an angle of not more than 10 to 15 insert gently to avoid damaging the contacts Step 3 Replace the end cap 4 and close it by turning in the direction indicated by the arrow Step 4 Test the drill to ensure it operates properly see Method of operation and Functional check on page 2 7 Main switch and reverse rotation L 6 Clockwise rotation R OVERVIEW 1 Cordless Drill 2 Battery Compatment 3 Recha...

Страница 8: ...d by the arrow Slide the chuck 2 onto the shaft 3 as far as it will go Release the chuck collar 1 Turn the chuck slightly until it engages in the shaft 3 Check the connection Hold the chuck 4 with your left hand and pull it away from the drill Fault Rectification Clutch does not engage in shaft If due to dirt clean the clutch if due to damage send to Customer Service 4 3 2 1 ...

Страница 9: ... 4 816 Desktop Charger dual 240V and 115V charging time 60 minutes Please state required voltage when ordering 6 REF 4 830 Three jaw chuck 0 5 mm to 7 0 mm capacity for round and triangular shanks incl chuck key 7 REF 4 834 Reduction gears with AO standard clutch large Speed 0 150 rpm 8 REF 4 836 Oscillating saw with AO connection for saw blades 9 REF 4 837 Sternum saw 10 REF 4 842 Quick action ch...

Страница 10: ...rt time before the operation 4 Remove blood and other exudates from instruments and attachments during the operation replace instruments and attach ments in their assigned place after use 5 Flush through cannulated instruments to prevent blood and bone powder from drying on 6 Use Ringer s lactate solution or saline solution to clean instruments and accessories but do not immerse them in solutions ...

Страница 11: ...ut packaging then drying is not necessary 5 LUBRICATION The joints and all moving parts of instruments and attachments must be cleaned and lubricated after use Only use biological oils and acid free lubricants pure cooking oil is recommended If special instrument oil solutions are used the instruments and attachments can be immersed for a certain period of time With some instrument washing machine...

Страница 12: ...809 4 810 warm up but this does not indicate a fault As soon as the BATTERY 4 809 4 810 is fully charged the lamp glows green 2 Chargers 4 814 and 4 816 switch off automatically when the BATTERY 4 809 4 810 is fully charged This means that you can leave the BATTERY 4 809 4 810 in the operational Charger 4 814 4 816 for a prolonged period so that it is always charged to full capacity without any ri...

Страница 13: ...of work performed with the company stamp date and signature of the repairer WARNING All equipment must be cleaned before sending for servicing Transport and storage conditions To prevent damage The Charger 4 814 4 816 and BATTERY 4 809 4 810 must be transported in the aluminium case provided which has a special foam insert The same applies for correct storage of this device This device must only b...

Страница 14: ...ge 12 V Rated output current 1100 mA max Protection class II Degree of protection as per DIN EN 529 IPX0 Technical Data Function The Chargers 4 814 and 4 816 are controlled and monitored by a microcontroller Irrespective of the charge level of the battery the controller measures the momentary capacity and controls the charging process ...

Страница 15: ...15 Notice ...

Страница 16: ...MAT GmbH Co KG Friedrich Wöhler Straße 10 78576 Emmingen Liptingen Germany Phone 49 0 7465 909 188 Fax 49 0 7465 909 024 www mat medical com info mat medical com Revision 06 04 2010 Cordless Drill System User s Manual No 6 GB MAT ...

Отзывы: