17/03/2014 v2.2
ENGLISH
0
12/30
8
SET-UP (INITIAL SET-UP OF THE WELDING POWER SOURCE)
With locked status active it is not possible to access this function.
§ 8.1 LOCKING PROCEDURE
Set the welding power source ON/OFF switch to “O” to switch the unit off.
S4
Hold down the button.
Set the welding power source ON/OFF switch to “I” to switch on the unit.
SIMULTANEOUS ACTIONS
Set UP
The message appears for a few seconds on the following displays: D1-D2
The acronym relative to the setting to be edited appears on the following displays: D1
The value relative to the selected setting appears on the following displays: D2
E1
Using the encoder, select the setting to be changed.
E2
Using the encoder, edit the value of the selected setting.
E1
Select the following setting with the encoder:
ESC
S4
Press any button to save the setting and quit the menu.
Tab. 1 - Setup settings
ACRONYM
SETTING
MIN
DEFAULT
MAX
Coo
COOLER ACTIVATION
Aut
Aut
on
rC
REMOTE CONTROLLER SELECTION
oFF
oFF
06
oFF No control
03
n°1 potentiometer
04
n°2 potentiometers
05
n°1 UP/DOWN
06
n°2 UP/DOWN
LoC
ADJUSTMENTS BLOCK SELECTION
oFF
oFF
3
oFF All adjustments enabled.
1
All adjustments are disabled with the exceptions
shown in Tab. 2 page 13.
2
All adjustments are disabled with the exceptions
shown in Tab. 2 page 13.
3
All adjustments are disabled with the exceptions
shown in Tab. 2 page 13.
PP
PUSH PULL
on
oFF
oFF
bb
SELECTION OF BURN TYPE
SPc (*1)
Std
Std (*2)
*1: Anti-sticking function present to prevent the wire from sticking.
*2: No wire sticking control, just final wire cut.
Cooler activation
−
ON= The cooler is always running when the power source is switched on. This mode is preferable for heavy duty and automatic welding
procedures.
−
OFF= The cooler is always disabled because an air-cooled torch is in use.
−
AUT= When the unit is switched on the cooler is switched on for 15 s. During welding procedures the cooler runs constantly. When welding is
terminated the cooler continues to run for 90 s + a number of seconds equivalent to the average current value shown using the HOLD
function.
Содержание 321 HDP
Страница 1: ...17 03 2014 v2 2 ENGLISH 0 MasterWeld 321 HDP Instruction manual GB...
Страница 2: ...17 03 2014 v2 2 ENGLISH 0...
Страница 8: ...17 03 2014 v2 2 ENGLISH 0...
Страница 22: ...17 03 2014 v2 2 ENGLISH 0 22 30 15 SPARE PARTS 15 1 321 HDP...
Страница 24: ...17 03 2014 v2 2 ENGLISH 0 24 30 15 2 WIRE FEEDER MOTOR...
Страница 26: ...17 03 2014 v2 2 ENGLISH 0 26 30 16 ELECTRICAL DIAGRAM 16 1 321 HDP...
Страница 29: ...17 03 2014 v2 2 ENGLISH 0 29 30...
Страница 30: ...17 03 2014 v2 2 ENGLISH 0 30 30...