Mastervolt Solar ChargeMaster SCM-N 20 Скачать руководство пользователя страница 11

 
 
 
 
 

CONFIGURATION 

 

EN / Solar ChargeMaster 20, 40 / November 07

 11

 

 

6.1.4  Nightlight function (evening settings) 

Description Displays 

Settings 

 

Nightlight function 
EVENING OFF 

EVENING. Dusk to:  
1HR after dusk 

2HRS after dusk 

3HRS after dusk 

4HRS after dusk 

5HRS after dusk 

4HRS before mid of night 

3HRS before mid of night 

2HRS before mid of night 

1HRS before mid of night 

With the nightlight function type set 
to the EVENING/MORNING mode, 
you can set the EVENING timing in 
this menu.  
See section 5.4.2 for details. 
 
The default nightlight function 
EVENING is OFF. 

Mid of night 

 

6.1.5  Nightlight function (morning settings) 

Description Displays 

Settings 

 

 
MORNING OFF 

Morning From: …. to dawn 

1HR before dawn 

2HRS before dawn 

3HRS before dawn 

4HRS before dawn 

5HRS before dawn 

2HRS after mid of night 

3HRS after mid of night 

4HRS after mid of night 

5HRS after mid of night 
 

With the nightlight function type set 
to the EVENING/MORNING mode, 
you can set the MORNING timing in 
this menu.  
See section 5.4.2 for details. 
 
The default nightlight function 
MORNING is OFF. 

6HRS after mid of night 

Function

Setting

Settings menu

Function

Setting

Settings menu

Содержание Solar ChargeMaster SCM-N 20

Страница 1: ...Solar ChargeMaster SCM N 20 SCM N 40 INTELLIGENT CHARGE CONTROLLER MASTERVOLT Snijdersbergweg 93 1105 AN Amsterdam The Netherlands Tel 31 20 3422100 Fax 31 20 6971006 www Mastervolt com ENGLISH PAGE 1...

Страница 2: ...ement of the product Costs for installation labor or shipping of the defective parts are not covered by this guarantee 1 3 Validity of this manual All of the specifications provisions and instructions...

Страница 3: ...arly applies to chapter 2 Safety Guidelines and Measures 2 4 Maintenance repair In case of maintenance and repair activities disconnect batteries and PV modules to prevent unintentional damage to the...

Страница 4: ...stem For example street lights and road signs are often solar powered Overnight the battery is discharged during a preset time using the nightlight function Dusk to Dawn At day the battery is recharge...

Страница 5: ...4V 24V 72 44V 36V With a 12V system the Solar ChargeMaster 40 can supply a maximum power of 480W To connect higher power devices you will need more than one Solar ChargeMaster or change the system vol...

Страница 6: ...screws have to carry also the force applied by the wiring Mind the minimum required distance of 10 cm 4 to floor and ceiling this is necessary for ventilation reasons Installation step by step 1 Open...

Страница 7: ...ricted Normal operation Unrestricted Battery connected with wrong polarity to Unrestricted Unrestricted Unrestricted Reverse polarity at 24V system no 12V system yes Yes if only the battery is connect...

Страница 8: ...conditions are shown in the LCD screen if the Low Voltage Disconnect function shuts off the load output or in case of various other error conditions See chapter 7 for details Figure 9 Load control 5 3...

Страница 9: ...n dusk and dawn no real time setting is required It may take some days until the controller has learnt midnight This method can cause some inaccuracy but avoids any clock readjustment The controller s...

Страница 10: ...olyte In this menu you can select the proper battery type liquid electrolyte or GEL VRLA AGM according to your PV system to get better charge of your battery The default battery type is liquid electro...

Страница 11: ...his menu See section 5 4 2 for details The default nightlight function EVENING is OFF Mid of night 6 1 5 Nightlight function morning settings Description Displays Settings MORNING OFF Morning From to...

Страница 12: ...ge Day Night threshold 5 5 11 0 V Solar Voltage Day Night threshold 6 0 12 1 V Solar Voltage Day Night threshold 6 6 13 2 V Solar Voltage Day Night threshold 7 2 14 3 V Solar Voltage In this menu you...

Страница 13: ...section 4 4 1 Default Read in of current data Read in of current data Read back of data logger PC link bidirectional communication 6 1 9 Individual factory settings Description Displays Settings You c...

Страница 14: ...1 0 V Check if other sources overcharge the battery If not controller is damaged Loads are not supplied flashing symbols Battery wires or battery fuse damaged battery has high resistance Check battery...

Страница 15: ...e 13 7 27 4 V 25 C 13 7 27 4 V 25 C Load disconnect voltage 11 0 12 2 22 0 24 4 V depending on setting 11 0 12 2 22 0 24 4 V depending on setting Load reconnect voltage 12 8 25 6 V 12 8 25 6 V Tempera...

Страница 16: ...N 40 Is in conformity with the directives and standards 2006 95 EC Electrical Apparatus Low Voltage Directive 89 336 EEC Electromagnetic compatibility directive 93 68 EEC CE marking EN 60730 1 Electr...

Отзывы: