6.2
MasterBus configuration
Parameters below can be changed via the MasterBus network. DIP switch settings overrule MasterBus settings. If DIP switches
are not set to default, the corresponding MasterBus configuration is greyed out
Value
Meaning
Default
Adjustable range
Device
Language
Language that is displayed on a
monitoring device connected to the
MasterBus
English
English, Nederlands, Deutsch,
Français, Castellano, Italiano,
Norsk, Svenska, Suomi, Dansk
Device name
Name of this particular device in
MasterBus. This name will be recognized
by all devices that are connected to the
MasterBus network.
MCU [Serial
number]
All names with a maximum of 12
characters.
Lock config
Option to lock the configuration (installer
login).
Not checked
Not checked, Checked
Factory settings
Option to reset the configuration to
default (installer login).
Not selected
Not checked, Selected
System
MasterBus power
Checkbox to have the Combi power
MasterBus or not.
Checked
Checked, Not checked
Silent mode
Activate this mode to reduce the sound of
the cooling fans. This may affect the
charging time.
Not checked
Not checked, Checked
Silent mode
Maximum fan speed
36 %
25-100 %
Shunt device select
Select a device in the list, the values of
which must be used by the Mass Combi
Pro.
No shunt
Shunt devices in the list
Main charger
Maximum current
Maximum charging current adjustable.
100 A
1..150 A / 1..100 A / 1..50 A
Method
Charging method selectable.
3-Step+, refer to
chapter 3
3-Step+, constant voltage
Battery type
Select the main battery type.
Flooded (Lead acid
wet cell)
User defined, Flooded, Gel, AGM,
Spiral, MLi, Flooded traction, Nickel
Cadmium
Bulk
Bulk voltage
Maximum Bulk voltage (adjustable if User
Defined).
14.40/28.80/57.60 V
8..16.00/16..32.00/32..64.00 V
Min bulk time
Minimum time that the charger stays in
Bulk mode.
2 min
0-600 min
Start bulk time
Voltage at which to start the bulk timer.
13.25/26.50/53.00
Max bulk time
Maximum time the bulk phase lasts
before the charger changes to
absorption.
480 min
0-600 min, Max bulk time > Min bulk
time
Bulk ret. volt.
Bulk return voltage. If the battery voltage
has dropped below this voltage, the
charger will return to bulk phase.
12.8/25.6/51.2V
Bulk return time
Delay time before the charger returns to
Bulk after reaching the Return to Bulk
voltage.
30 sec
0-255 sec
Absorption
Abs. voltage
Absorption voltage (adjustable if User
Defined is selected.
14.25/28.50/57.0 V
8-16.00/16-32.00/32-64.00 V
Max absorp.time
Maximum time that the charger stays in
absorption mode.
240 min
1-65535 min
Return amps
Charging current at which the charger
changes to Float phase.
9.0 A / 6.0 A / 3.0 A
0.0-25.0
Min absorp.time
Minimum time that the charger stays in
absorption mode.
15 min
0-255 min