SPECIFICATIONS MASTERVOLT AGM BATTERIES 

 

Model 

AGM-55Ah AGM-70Ah AGM-90Ah AGM-130Ah 

Part 

number 

62000550 62000700 62000900 62001300 

Nominal 

voltage 

12V 12V 12V 12V 

Nominal capacity (C20) 

55Ah 

70Ah 

90Ah 

130Ah 

Reserve capacity* 

80 min 

113 min 

179 min 

240 min 

Number of cells per battery 

Maximum 

charge 

current: 

15.3A 19.5A 25.5A 36A 

Approximate weight: 

17.0 kg / 37 Lbs 

21.0 kg / 46 Lbs 

28.0 kg / 62 Lbs 

37.6kg / 83 Lbs 

BCI group number 

24 

27 

31 

- - 

Terminal: threaded insert stud 

M6 

M8 

M8 

M8 

CCA to DIN 

250 A 

290 A 

360 A 

590 A 

CCA to SAE 

400 A 

460 A 

570 A 

940 A 

 

Model AGM-160Ah 

AGM-225Ah 

AGM-270Ah 

Part number 

62001600 

62002250 

62002700 

Nominal voltage 

12V 

12V 

12V 

Nominal capacity (C20) 

160Ah 

225Ah 

270Ah 

Reserve capacity* 

351 min 

474 min 

600 min 

Number of cells per battery 

Maximum charge current: 

45A 

63A 

76.5A 

Approximate weight: 

42.3 kg / 93 Lbs 

62.5 kg / 138 Lbs 

73.0 kg / 161 Lbs 

BCI group number 

4D 

8D 

Super 8D 

Terminal: threaded insert stud 

M8 

M8 

M8 

CCA to DIN 

550 A 

680 A 

750 A 

CCA to SAE 

870 A 

1080 A 

1200 A 

 

General 

 

Operating temperature 

–20 to 55ºC / –4 to 131ºF;  

Nominal operating temperature: 

5 to 35ºC / 41 to 95ºF, recommended at 25ºC/ 77ºF 

Storage temperature: 

–25°C to 85°C / –13°F to 185°F 

Compliancy: EU 

Directive 

2006/66/EC 

* Reserve capacity = time a battery can be loaded with 25 Amps at 80ºF (26,7ºC) until the battery voltage is 10.5V  
 

© 2015, Mastervolt BV, Snijdersbergweg 93, 1105 AN Amsterdam, The Netherlands 

Tel: + 31-20-3422100 Fax: + 31-20-6971006 Email: [email protected] 

 

Mastervolt cannot be held liable for possible errors in the manual and the consequences of these 

Mastervolt kan niet aansprakelijk worden gesteld voor eventuele fouten in de handleiding en de gevolgen daarvan. 

Mastervolt kann nicht haftbar gemacht werden für: eventuelle Fehler in der Anleitung und die daraus entstehenden Folgen. 

Mastervolt décline toute responsabilité dans les cas suivants éventuelles erreurs dans le manuel et leurs conséquences. 

En ningún caso Mastervolt asumirá responsabilidad alguna derivada de eventuales errores en el manual de instrucciones y sus posibles consecuencias. 

La Mastervolt declina ogni responsabilità per eventuali errori o omissioni nelle istruzioni per l'uso e le conseguenze che ne derivano. 

Содержание AGM 130Ah

Страница 1: ...NG MODE D EMPLOI MANUAL DE UTILIZACION INSTRUZIONI PER L USO AGM BATTERY 55Ah 70Ah 90Ah 130Ah 160Ah 225Ah 270Ah MASTERVOLT Snijdersbergweg 93 1105 AN Amsterdam The Netherlands Tel 31 20 342 21 00 Fax...

Страница 2: ...ug to the battery post is recommended Therefore the battery pole adapter should be removed first See figure 6 Use properly sized and reliable cable lugs and battery terminals Tighten all connections f...

Страница 3: ...volen Verwijder daartoe eerst de opschroefbare accupool Zie figuur 6 Gebruik betrouwbare en correct gedimensioneerde kabelogen en accuklemmen Draai alle aansluitingen goed vast Sluit de accu met de ju...

Страница 4: ...Batteriepol Adapter entfernt werden Siehe Abbildung 6 Verwenden Sie korrekt dimensionierte und zuverl ssige Kabelschuhe und Batterieklemmen Ziehen Sie alle Anschl sse fest an Schlie en Sie die Batter...

Страница 5: ...erie doit donc tre retir en premier Se r f rer la Figure 6 Utiliser des cosses de c bles et des bornes de batteries de tailles appropri es et fiables Serrer fermement toutes les connexions Connecter l...

Страница 6: ...a bater a V ase la figura 6 Habr que usar terminales para cable y para los bornes de la bater a que sean fiables y del tama o adecuado Las conexiones se deben apretar firmemente Habr que conectar la b...

Страница 7: ...o togliere innanzitutto l adattatore del polo della batteria Vedere la figura 6 Utilizzare spinotti e morsetti dalle dimensioni adeguate ed affidabili Stingere a fondo tutti i collegamenti Collegare l...

Страница 8: ...ng Parallel connection Parallelschaltung Connexion en parall le Conexi n en paralelo Collegemento in parallelo Connection of the plus and minus wiring must be crosswise Aansluiting van de plus en min...

Страница 9: ...103 AGM 225Ah 226Ah 210Ah 180 5Ah 163 8Ah 126Ah AGM 270Ah 270Ah 255Ah 229Ah 214Ah 176Ah FINAL DISCHARGE VOLTAGE Battery model Discharge current Ontlaadstroom Entladestrom Courant de d charge Corriente...

Страница 10: ...20 4 18 1 14 3 12 0 6 4 AGM 160Ah 390 0 318 6 245 5 179 0 122 4 92 0 54 2 40 6 30 8 26 8 23 5 18 2 15 0 8 0 AGM 225Ah 315 0 241 5 168 0 126 0 73 5 54 6 42 0 36 1 31 9 25 0 21 0 11 3 AGM 270Ah 318 4 22...

Страница 11: ...h 62002250 Not to scale Niet op schaal Nicht massstaeblich Sans chelle pr cise Senza scala definita Dimensions in mm See www mastervolt com batteries for detailed drawings Battery casing material ABS...

Страница 12: ...80 A 1200 A General Operating temperature 20 to 55 C 4 to 131 F Nominal operating temperature 5 to 35 C 41 to 95 F recommended at 25 C 77 F Storage temperature 25 C to 85 C 13 F to 185 F Compliancy EU...

Отзывы: