SAFETY GUIDELINES AND MEASURES 

 

 

 

6

 

January 2013/ Alpha alternator - Alpha Pro II regulator / EN 

2.5 

GENERAL  SAFETY  AND  INSTALLATION 
PRECAUTIONS  

  Before  using  the  Alpha  alternator  /  Alpha  Pro  II 

regulator,  read  all  instructions  and  cautionary 
markings  on  the  Alpha  alternator  /  Alpha  Pro  II 
regulator,  the  batteries,  and  all  appropriate 
sections of the manual. If you do not follow these 
instructions  danger  may  occur  or  the  unit  could 
be damaged.  

  The  Alpha  alternator  /  Alpha  Pro  II  regulator  is 

designed  to  be  permanently  connected  to  your 
DC  electrical  systems.  Mastervolt  recommends 
that all wiring be done by a certified technician or 
electrician  to  ensure  adherence  to  proper 
electrical wiring regulations.  

  Wrong  use  of  the  mode  selector  will  lead  to 

serious damage to batteries, the Alpha alternator, 
the Alpha Pro II regulator and the cabling. 

  Wrong  MasterBus  settings  will  lead  to  serious 

damage  to  batteries,  the  Alpha  alternator,  the 
Alpha Pro II regulator and the cabling.  

  Selection  of  a  MasterShunt  connected  to  a 

battery  with  a  different  nominal  voltage  will  lead 
to  serious  damage  to  batteries,  the  Alpha 
alternator,  the  Alpha  Pro  II  regulator  and  the 
cabling. 

  Be  aware  of  parts  that  can  be  hot:  not  only 

engine parts, but the alternator as well.  

  In case of fire, you must use the fire extinguisher 

which is appropriate for electrical equipment.  

  Short  circuiting  or  reversing  polarity  will  lead  to 

serious damage to batteries, the Alpha alternator, 
the Alpha Pro II regulator and the cabling. Fuses 
between  the  batteries  and  the  electrical 
installation  can  not  prevent  damage  caused  by 
reversed polarity and the warranty will be void.  

  Secure  the  DC  wiring  with  a  fuse,  according  to 

the  guidelines  in  this  manual.  Connection  and 
protection must be done in accordance with local 
standards.  

  Do not work on the Alpha alternator, Alpha Pro II 

regulator  or  parts  of  the  electrical  system  if  it  is 
still  connected  to  a  current  source.  Only  allow 
changes  in  your  electrical  system  to  be  carried 
out by qualified electricians.  

 

2.6 

WARNING  REGARDING  LIFE  SUPPORT 
APPLICATIONS 

Mastervolt  products  are  not  sold  for  applications  in 
any  medical  equipment  intended  for  use  as  a 
component  of  any  life  support  system  unless  a 
specific  written  agreement  pertaining  to  such 
intended use is executed between the manufacturer 
and  Mastervolt.  Such  agreement  will  require  the 
equipment  manufacturer  either  to  contract  for 
additional  reliability  testing  of  the  Mastervolt  parts 
and/or to commit to undertake such testing as a part 
of  the  manufacturing  process.  In  addition  such 
manufacturer  must  agree  to  indemnify  and  hold 
Mastervolt  non  responsible  from  any  claims  arising 
out  of  the  use  of  the  Mastervolt  parts  in  the  life 
support equipment. 
 

2.7 

WARNING  REGARDING  THE  USE  OF 
BATTERIES.  

Excessive  battery  discharge  and/or  high  charging 
voltages will cause  serious damage to batteries. Do 
not  exceed  the  recommended  limits  of  discharge 
level  of  your  batteries.  Avoid  short  circuiting 
batteries,  as  this  may  result  in  explosion  and  fire 
hazard. Installation of the batteries and adjustments 
of the Alpha alternator / Alpha Pro II regulator should 
only be undertaken by authorised personnel!  
 

 

Содержание 45512000

Страница 1: ...UEL UTILISATEURS ALPHA ALTERNATOR 12 90 12 130 24 75 24 110 24 150 HIGH OUTPUT ALTERNATORS WITH ALPHA PRO II REGULATOR MASTERVOLT Snijdersbergweg 93 1105 AN Amsterdam The Netherlands Tel 31 20 3422100...

Страница 2: ...and installation precautions 6 2 6 Warning regarding life support applications 6 2 7 Warning regarding the use of batteries 6 3 HOW IT WORKS 7 3 1 Alpha alternator 7 3 2 Alpha Pro II regulator 7 3 2 1...

Страница 3: ...MasterBus network 19 6 3 MasterBus functions 20 6 3 1 Monitoring 20 6 3 2 Alarms 20 6 3 3 History 20 6 3 4 Configuration 21 6 3 5 Alpha Pro II event source list Alpha Pro II as event source 22 6 3 6...

Страница 4: ...t with the locally applicable standards and taking into consideration the safety guidelines and measures section 2 of this manual Keep this manual at a secure place 1 2 GUARANTEE SPECIFICATIONS Master...

Страница 5: ...correct condition in a closed well ventilated room protected against rain moist dust and condensation observing the instructions in the users manual WARNING Never use the Alpha alternator Alpha Pro I...

Страница 6: ...abling Fuses between the batteries and the electrical installation can not prevent damage caused by reversed polarity and the warranty will be void Secure the DC wiring with a fuse according to the gu...

Страница 7: ...tage regulator controls the alternator s output voltage It is designed for optimal recharging of both wet gel AGM and li ion batteries Battery charging is accomplished in three automatic stages BULK A...

Страница 8: ...ure sensor is not included in the delivery of the Alpha Pro II regulator By installing this battery temperature sensor the charge voltages are automatically adapted for deviating temperatures Figure 3...

Страница 9: ...r the alternator Note that the alternator support has to be made suitable for handling the high forces as well CAREFUL Any changes to the alternator including the alternator s wiring pulley and or mou...

Страница 10: ...a clockwise or counter clockwise direction 4 4 3 Mounting step by step 1 Determine the alternator mounting location 2 Loosely attach the mounting bracket to the engine with the mounting engine bolts P...

Страница 11: ...nsition resistance as far as possible Use cables of the correct size See specifications section 9 for recommended wire sizes Use the supplied cable assembly for connection of the Alpha Pro II regulato...

Страница 12: ...rminal of the Alpha Pro II regulator Connect the other wire end through a switch S1 with normally open contacts to the positive pole of the battery as indicated You can use the ignition switch figure...

Страница 13: ...at mode Switching on some loads during operation will solve this problem Figure 9 Connection of a tachometer position of the terminals may differ see APPENDIX figures A 6 till A 9 The Alpha Pro II reg...

Страница 14: ...positive pole of the battery Do not connect these wires to the input of the battery isolator NOTE As battery voltage sensing is performed by the Alpha Pro II regulator you can use a battery isolator t...

Страница 15: ...before the configuration can be locked and the Alpha Pro II made operational see Chapter 6 for more extensive explanation on using MasterBus 1 Go to Configuration page 2 Go to group System and select...

Страница 16: ...he engine is running be aware of moving parts like V belts NOTE See section 3 2 1 for explanation of the bulk absorption and float mode Be sure no loads or any other charging sources are on Be sure th...

Страница 17: ...to indicate Bulk phase 3 Yellow LED tot indicate Absorption phase 4 Yellow LED to indicate Float phase 5 Green LED to indicate MasterBus traffic Figure 16 Connections of the Alpha Pro II regulator 1 2...

Страница 18: ...ng purposes Changing absorption time is possible with the mode selector in MasterBus 9 o clock position and the configuration unlocked Refer to section 6 3 4 Adjustable range 0 minutes up to 10 hours...

Страница 19: ...configuration Mastervolt also offers several interfaces like the Modbus interface making even non MasterBus devices suitable to operate in the MasterBus network For central monitoring and control of...

Страница 20: ...of charge Battery state of charge calculated by the shunt Battery voltage Battery voltage V measured by the MasterShunt Battery current Battery current A measured by the MasterShunt Battery temp Batte...

Страница 21: ...login RPM event at Number of revs at which an event takes place 1000 rpm 200 10000 rpm Small engine Option to minimize torque load by decreasing charging current This prevents a small engine from stal...

Страница 22: ...ist in manual of the selected device Event x data Data is linked to the command See also figure 16 Off Off On Copy Copy Invert Toggle Event x 1 The next event appears after enabling Event x Disabled S...

Страница 23: ...Shunt connected many things are different using the Alpha Pro II regulator 1 There are two options to place a temperature sensor The MasterShunt temperature sensor is preferably placed onto the batter...

Страница 24: ...150 running hours or at least every year whatever comes first Make sure that the alternator is securely mounted to its applicable brackets The brackets in turn need to be bolted securely to the engine...

Страница 25: ...nal is 12 24V Voltage on the reg on terminal of the regulator is 0V Engine is not running Start the engine 2 Amps fuse in brown wire is blown Check the 2 Amps fuse and replace if necessary Problem wit...

Страница 26: ...switch S1 must be open when the engine is not running Check wiring between battery and reg on terminal Output voltage too high The regulator measures a too low battery voltage and tries to compensate...

Страница 27: ...pe A type Weight 5 5 kg 12 1 lbs 10 1kg 22 3 lbs Number of mounting positions 3 1 24V models Model 24 75 24 110 24 150 Part number 48524075 48524110 48524150 Type enclosure see APPENDIX B B C Charge c...

Страница 28: ...le range absorption Li ion 13 15V 26 30V Adjustable range float Li ion 13 13 9V 26 27 8V Battery temperature compensation 30mV C Absorption time 4 hours adjustable range 0 min up to 24 hours Cable ass...

Отзывы: