![Mastervolt 12/2000-100 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/mastervolt/12-2000-100/12-2000-100_user-and-installation-manual_1738957023.webp)
CombiMaster 120V Series – User and Installation Manual
23
Adding the CombiMaster Inverter/Charger to a CZone network
1
Disconnect the backbone at the closest backbone connection
and add in a tee connector.
2
Reconnect the backbone connection with the new tee connector
in place.
3
Connect the RJ45 CZone drop cable to the black coupler on the
tee and then plug the connectors into either of the
communication ports of the CombiMaster Inverter/Charger.
Adding the CombiMaster Inverter/Charger to a MasterBus
network
1
Disconnect a MasterBus cable or Terminator from the closest
MasterBus device and connect it to the CombiMaster
Inverter/Charger.
2
Connect the new MasterBus cable to the other MasterBus device
and then connect to the CombiMaster Inverter/Charger.
3
Ensure that the network is properly terminated.
Step 12.
Option: use a small screwdriver to change DIP switch settings. See section 5.1 on page 25.
Note:
if added to a CZone network, the DIP switches are
used to set the CZone address.
Step 13.
Option: connect external alarm or remote switch input. See section 4.8.
Step 14.
Set the desired output voltage and other configuration settings using a remote control panel
or the DIP switches, see chapter 5 on page 25.
Step 15.
Check all wiring. If all wiring is OK: open the safety switch (if available) and place the inverter
fuse.
WARNING
!
When the fuse is placed, internal capacitors may cause a spark. This is normal.
Step 16.
Close the connection compartment and fix the screws at the bottom.
Step 17.
Close the safety switch (if available) and switch on the CombiMaster Inverter/Charger.
4.8 Accessories connector (dry contacts)
The screw terminal at the bottom side of the CombiMaster
Inverter/Charger, offers the following contacts:
Remote
switch input
Alarm output