NOTE:
If the inverter displays any alarm message as listed in Table 9.1; please turn
off the inverter (refer to Section 6.2 to stop your inverter) and wait for 5 minutes
before restarting it (refer to Section 5.1 to start your inverter). If the failure
persists, please contact your local distributor or the service center. The below
that we will need so that we can assist you.
1. Serial number of the Inverter;
2.
The distributor/dealer of the Inverter (if available);
3.
Installation date.
4.
The description of problem (i.e. the alarm message displayed on the LCD and the
status of the LED status indicator lights. Other readings obtained from the Information
submenu (refer to Section 7.2) will also be helpful.);
5. Your contact details.
10. Specification
3/N/PE~400
.48.
.49.
9. Troubleshooting
47...52 or 57...62
Max. DC input voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
MPPT number/Max input strings number
Rated grid voltage (Volts)
Rated output current (Amps)
Power Factor (at rated output power)
Operating frequency range (Hertz)
Max.efficiency
EU efficiency
MPPT efficiency
Max. DC input power (Watts)
Grid voltage range (Volts)
Model
Dimensions
Weight
Topology
Operating ambient temperature range
Ingress protection
Noise emission (typical)
Cooling concept
Max.operation altitude
Designed lifetime
Connention
Grid connection standard
Operating surroundings humidity
530W*700H*356.5D (mm)
1000
18+18+18+18
23.4+23.4+23.4+23.4
4/8
304...460
0.8leading~0.8lagging
50/60
98.6%
98.3%
99.9%
57.2kg
Transformerless
IP65
<30 dBA
Natural convection
4000m
>20 years
-25℃...60℃
Display
Monitoring
Communication connections
Warranty Terms
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
0...100% Condensing
Mc4 connector and Ip67 rated plug
7.0"LCD color screen display
WiFi or GPRS
4 pins RS485 connector , 2 RJ45 connector
5 Years STD (Extendable to 20 Years)
EN50438, G83/2,G98, G99, AS4777.2:2015,
VDE0126-1-1, IEC61727, VDE N4105
600
20000
22000
22000
28.7
Beta
-20K
24000
THDi (at rated output power)
<3%
200...800
Start-up voltage (Volts)
350
Max short circuit input current (Amps)
Rated DC voltage (Volts)
Rated grid frequency (Hertz)