12
OPERATION
2.4 To Start
1. Open the fuel shut-off valve by moving the fuel cock level to the open position.
2. Set the engine ON/OFF switch to the “ON” position.
3. Grip the recoil starter handle and pull it until you feel slight resistance. Then pull
sharply and quickly. Return the recoil starter handle to the starter case before
releasing.
4. Grip the recoil starter handle and pull it a little to feel a slight resistance. Then pull it
powerfully from there. To release the handle do not release it at the position where it
has been pulled to, but release it after returning closely to the starter case.
5. If the engine has started, while listening to explosion sounds, return the choke lever
slowly to full-open position. Be sure to perform a warm-up run for the period 3 to 5
minutes at low speed, while paying careful attention to gas leakage or abnormal
sound.
6. If it is difficult to start the engine by repeatedly pulling the starter rope, remove
ignition plug and check the sparking performance. If the plug is wet due to excessive
fuel intake or soiled, replace the coil or clean sufficiently to its internals. With the
ignition plug removed, pull the recoil starter handle 2-3 times to discharge excessive
blended gas.
Содержание SG70
Страница 7: ...7 SAFETY INFORMATION 1 4 Label Locations...
Страница 22: ...22 Distributed By TEKPAC ENGINEERING CO LTD Version Rammer 01 2013...