OPERATION
1. To verify primary pump operation, fill the sump pit with enough water to trigger operation. The primary
sump pump will start, pump out the water then stop.
2. Unplug the primary pump power cord plug from the power supply outlet.
3. To verify DC pump operation, refill the sump pit with water until the DC pump float switch moves to the
upper end. The DC pump should start and pump out the water. If it does not operate, please check all
the wire connections.
SPECIFICATIONS
• Water-cooled, high-efficiency motor for extended operation during power outages.
• Use a deep-cycle marine battery for maximum performance.
• High-quality surface finish and corrosion-resistant thermoplastic structure for long life with minimum
maintenance.
• Reliable reed-sensor water detection for automatic operation.
• Includes controller, charger, float switch, pump, and battery box.
• Easy installation without any major plumbing changes.
NOTE:
Pump must be filled with water before operation. Running the pump dry will cause damage to the shaft seal.