model no. 062-3425-4 | contact us 1-800-689-9928
12
INSTALLATION INSTRUCTIONS
This pump is pre-wired at
230 V. If the power source is
115 V, remove the electrical
housing cover. Flip the switch
to 115 V. Replace the cover.
13
14
To prime, remove both:
a. The plug from the top of the
discharge tee (water will be
filled in here); and
b. The priming plug in front of the
discharge tee (this is to allow
air to vent out while priming).
Fill the discharge tee with water
until water overflows.
NOTE:
It may take several minutes or more
to fill the pipes and the pump (A) completely.
Watch the water level in the discharge tee.
Make sure the water level is stable and there
are no air bubbles.
WARNING:
If the pump is lower than the
suction pipe, air may trap in the pipe. The
pump may not work properly. Make sure the
pipe slopes away from the pump.
Wrap the discharge tee plug and
priming plug threads with thread
tape and re-attach to the pump (A).
Tighten with wrench.
NOTE:
All electrical work should be
performed by a licensed electrician.
115
230