ASSEMBL

Y INSTRUCTIONS

INSTALLATION

NOTE:

• A 5” (12.7 cm) space is needed from sink bottom to inlet for proper operation, refer to Figure 2. 

• DO NOT use plumber’s pipe threading compound (“pipe dope”) on plastic pipe; it can damage the plastic, 

causing leaks and piping failure and void the warranty. 

• Be careful to avoid cross-threading. Use only a plastic-compatible pipe-threading compound or non-stick tape 

when connecting threaded fittings to plastic adaptors. 

• DO NOT use plumber’s pipe threading compound (“pipe dope”) on plastic pipe; it can damage the plastic, 

causing leaks and piping failure and void the warranty. 

• If the sink-drain tail piece is not 1 1/2” (3.8 cm) NPT, you will have to adapt it (bushings, reducers, etc.) In this 

case, wrap all joints with PTFE pipe thread sealant tape before making connections. 

• The vertical height from the check valve to the pipe outlet should be at least 6 1/2’ (2 m) to void check valve 

leakage.

Fittings Supplied:                                                             Qty.
A. Sink Drain Screen                                                            1
B. 1 1/4” (3.2 cm) NPT x 1 1/4” (3.2 cm) Slip Check Valve    1
C. 1 1/4” (3.2 cm) NPT Ball Valve                                          1

Purchase Separately:                                                        Qty.
1. 1 1/2” (3.8 cm) NPT x 1 1/2” (3.8 cm) 
     Slip Female Adaptor                                                         1
2. 1 1/2” (3.8 cm) Schedule 40 PVC Pipe, to fit                     1
3. 1 1/2” (3.8 cm) NPT x 1 1/2” (3.8 cm) Slip Male Adaptor   1
4. 1 1/4” (3.2 cm) NPT Galvanized Nipple, to fit                     1
5. 1 1/4” (3.2 cm) NPT Galvanized Union                               1
6. 1 1/4” (3.2 cm) NPT x 1 1/4” (3.2 cm) Male Adaptor          2
7. 1 1/4” (3.2 cm) Schedule 40 PVC Pipe, to fit                      2
8. 1 1/4” (3.2 cm) Socket to Socket 90° Elbow                      1
9. 1 1/4” (3.2 cm) Schedule 40 PVC Pipe to Drain   As Needed
PVC Pipe Cement                                                    As Needed
PTFE pipe thread sealant tape                                 As Needed
1 1/2” (3.8 cm) PVC Solvent Union – optional          As Needed

1.  Place the sink in its final location.
2.  Remove any existing drain fittings back to the tail piece. Make sure the existing tail piece does not 

leak.

3.  Glue the 1 1/2” (3.8 cm) PVC pipe into the female adaptor (Part No.1). 
4.  Wrap the threads of the tail piece with 1 to 1 1/2 turns of PTFE pipe thread sealant tape. Thread the 

1 1/2” (3.8 cm) NPT female adaptor (Part No.1) onto the sink-drain tail piece. Thread it hand tight 
plus 1/2 turn with a pipe wrench or slip joint pliers. DO NOT overtighten.

5.  Wrap the threads of the 1 1/2” (3.8 cm) male adaptor (Part No. 3) with 1 to 1 1/2 turns of PTFE pipe 

thread sealant tape and install it in the pump inlet. Tighten it hand tight plus 1/2 turn with a pipe 
wrench or slip joint pliers. DO NOT overtighten!

WARNING!

• Electric Shock Hazard. Plug pump into a properly grounded, GFCI-protected outlet. Do NOT plug in the pump until after it is 

completely installed. Do not remove or modify the grounding pins on the plugs. 

• Fire and explosion hazard. Be sure to follow the cement manufacturer’s instructions when using PVC cement. Do not use 

near fire or open flame.

Figure 1: 
Typical method of mounting the pump

1 1/2" (3.8 cm)

1 1/2" (3.8 cm)

1 1/4" (3.2 cm) 

Содержание 062-3420-4

Страница 1: ...s IMPORTANT Please read this manual carefully before running this utility sink pump and save it for reference INSTRUCTION MANUAL AUTOMATIC UTILITY SINK PUMP Model No 062 3420 4 ...

Страница 2: ...headline bars continuation tabs notes warnings headline bars continuation tabs notes warnings ...

Страница 3: ...al contains important safety and operating instructions Read all instructions and follow them with use of this product TABLE OF CONTENTS Quick Start Guide 4 Technical Specifications 6 Safety Guidelines 8 Key Parts Diagram 11 Assembly Preparation 12 Assembly Instructions 13 Operating Instructions 14 Maintenance 16 Troubleshooting 17 Warranty 18 TABLE OF CONTENTS ...

Страница 4: ...nk tail pipe using 1 1 2 3 8 cm pipe 1 NOTE A 5 12 7 cm space is needed from sink bottom to inlet for proper operation Do NOT use plumber s pipe threading compound pipe dope on plastic pipe it can damage the plastic causing leaks and piping failure and voiding the warranty Be sure check valve is installed with arrows pointing away from pump Sink tail pipe 1 1 2 3 8 cm Female Adaptor 5in Min 1 1 4 ...

Страница 5: ...lled plug the switch into the GFCI protected properly grounded outlet Plug the pump into the back of the switch s plug 4 TEST PUMP Fill the sink with water and adjust the flow using the included ball valve 5 GFCI Outlet Switch Cord Pump Cord GFCI Outlet Ball valve ...

Страница 6: ...l seal Cord length 8 2 4 m Upper bearing Sleeve bearing Lower bearing Sleeve bearing Single phase Permanent split capacitor PSC Motor protection Auto reset thermal overload protection in motor Construction material Steel for motor house plastic for volute and impeller Motor Squirrel cage induction class B insulation Maximum flow 1300 U S GPH 4921 L hr Maximum head height 15 4 6 m MOTOR AND ELECTRI...

Страница 7: ... 1300 4 921 950 3 598 550 2 083 0 0 DIMENSIONS PERFORMANCE CHART Friction loss in piping not included in measurement 7 9 32 18 5 cm 1 1 2 3 8 cm NPT 1 1 4 3 2 cm NPT 1 1 4 3 2 cm NPT 1 1 4 3 2 cm NPT 12 13 64 30 99 cm 4 10 16 cm 4 13 32 11 18 cm 1 1 2 3 81 cm 29 64 1 14 cm 3 51 64 9 65 cm 7 21 32 19 43 cm ...

Страница 8: ... oil gasoline kerosene ethanol etc Do not use in the presence of flammable or explosive vapours Using this pump with or near flammable liquids can cause an explosion or fire resulting in property damage serious personal injury and or death Risk of electric shock Never remove the ground terminal on the three pronged power plug of the pump as the ground terminal is designed for protection Do not adj...

Страница 9: ... have the paint scratched damaged or worn should be recoated with a water based air dry enamel paint All surfaces should then be sprayed with a rust inhibiting oil Pump should be stored in its original shipping container On initial start up rotate impeller by hand to assure seal and impeller rotate freely INSTALLATION DISCHARGE Please see the step 2 of page 4 for details ELECTRICAL CONNECTIONS Pum...

Страница 10: ... identification plate and record at the end of the manual for future reference INSULATION TEST Before the pump is put into service an insulation megger test should be performed on it The ohm values as well as the volts and amps should be recorded PUMP DOWN TEST After the pump has been properly wired and lowered into the basin sump or lift station it is advisable to check the system by filling with...

Страница 11: ...PARTS DIAGRAM PARTS LIST No Description Qty 1 Diaphragm Switch 1 2 Pump 1 3 1 1 4 3 2 cm NPT Ball Valve 1 No Description Qty 4 1 1 4 3 2 cm NPT x 1 1 4 3 2 cm Slip Check Valve 1 5 Sink Drain Screen 1 1 3 4 5 2 ...

Страница 12: ...is pump is designed to be used with a sink where a gravity drain line is not available Attach the pump to the drain tail piece the pump will start when water begins to drain Uses include basement laundry sinks wet bars and utility sinks Flathead screwdriver Hacksaw Safety goggles Tape measure Cross head screwdriver Channel lock pliers Pipe wrench ...

Страница 13: ...Galvanized Union 1 6 1 1 4 3 2 cm NPT x 1 1 4 3 2 cm Male Adaptor 2 7 1 1 4 3 2 cm Schedule 40 PVC Pipe to fit 2 8 1 1 4 3 2 cm Socket to Socket 90 Elbow 1 9 1 1 4 3 2 cm Schedule 40 PVC Pipe to Drain As Needed PVC Pipe Cement As Needed PTFE pipe thread sealant tape As Needed 1 1 2 3 8 cm PVC Solvent Union optional As Needed 1 Place the sink in its final location 2 Remove any existing drain fittin...

Страница 14: ...half of the 1 1 4 3 2 cm union Part No 5 onto it hand tight plus 1 1 2 turns with a pipe wrench or slip joint pliers 11 At this time wrap the threads on both the 1 1 4 3 2 cm male adaptors Part No 6 with 1 1 2 to 2 turns of PTFE pipe thread sealant tape Thread one of the adaptors into the other half of the 1 1 4 3 2 cm union Part No 5 hand tight plus 1 2 turn with a wrench or a pair of slip joint ...

Страница 15: ...ll start Adjust the discharge ball valve C until the pump runs continuously while the faucets are running and the sink is draining If the water level rises with the pump on slightly open the discharge valve to balance the flow If it drops slightly close the discharge valve Washing machines usually discharge more water than the faucets do and it is normal for the water level to rise in the sink whi...

Страница 16: ... the pump Close the discharge ball valve C Bail out the sink as much as possible Disconnect the union Part No 5 unscrew the pump from the sink tail piece lower the pump to the floor and slide it out from under the sink see Figure 3 Remove the six housing screws see Figure 4 Clean out the pump Make sure that the pump discharge is clear If necessary replace the impeller Install the new gasket if nec...

Страница 17: ...is too high or too long 5 The check valve is installed backwards 1 Clear the drain screen 2 Unplug the pump Then open and clear discharge line 3 Open shut off valve slightly 4 Unplug the pump or reduce the height or length of the discharge line 11 3 35 m max height 5 Make sure the flow arrow on the check valve points away from the pump Pump cycles on and off when no water is in the sink 1 Check va...

Страница 18: ...lts sandpaper bits fluids tune ups or adjustments e this warranty will not apply where damage is caused by repairs made or attempted by others i e persons not authorized by the manufacturer f this warranty will not apply to any product that was sold to the original purchaser as a reconditioned or refurbished product unless otherwise specified in writing g this warranty will not apply to any produc...

Страница 19: ...WARRANTY ...

Страница 20: ......

Отзывы: