TROUBLESHOO
TING
19
AIR-POWERED SHEAR 058-7732-0
Note: For further repair information, please call 1
-
800
-
689
-
9928.
Tool stops working.
Air flows freely from
exhaust.
One or more motor vanes got stuck
due to material build up.
1. Pour pneumatic tool oil into the air inlet.
2. Tap motor housing gently with plastic mallet.
3. Operate the tool by reversing rotation back
and forth in short duration. Repeat the above
steps as needed.
4. Disconnect the air supply. Operate the
motor manually by rotating the drive shank
(wherever applicable)
.
If the problem persists, send tool for servicing
or return it to the store.
Tool does not shut
off.
Throttle valve O-rings are dislodged
from seat inlet valve.
Replace O
-
rings.
If the problem persists, send tool for servicing
or return it to the store.
PROBLEM
POSSIBLE CAUSES
SOLUTIONS