background image

7

8

2-GALLON (7.6 L) AIR COMPRESSOR - 058-7000-2

2-GALLON (7.6 L) AIR COMPRESSOR - 058-7000-2

A.  ELECTRIC MOTOR:

 The motor is used to power the pump.

B.  FUSE:

 The fuse is used to protect the motor.

C.  POWER SWITCH:

 This switch turns the compressor on and off. It is operated manually and when it 

is in the ON position, it allows the motor to start if the pressure in the air tank is below the factory 
set cut-in pressure, and allows the motor to stop if the pressure in the air tank reaches the factory 
set cut-out pressure. Be sure to set this switch to the OFF position when the compressor is not 
being used and before unplugging the compressor.

D.  AIR TANK:

 The tank is where the compressed air is stored.

E.  POWER CORD:

 This compressor should be 

used on a nominal 120 V grounded circuit. 
Use a power cord that is equipped with a 
grounding plug. Verify that the compressor 
is plugged into an outlet that has the same 
configuration as the plug. Do not use an 
adapter with this compressor.

Plug

Grounding pin

Grounded 
outlets

F.  SAFETY VALVE:

 This valve is used to prevent system failure by draining pressure from the system 

when it reaches a preset level if the pressure switch has not shut down the motor. It will pop open 
automatically, or it can be activated manually by pulling the ring on the valve.

G.  AIR PRESSURE REGULATOR:

 The regulator is used to adjust the pressure inside the line to the 

tool that is being used. Turn the knob clockwise to increase the pressure and counter-clockwise to 
decrease the pressure.

 

[  

WARNING!

 

Do not exceed the tool’s maximum working pressure.

H.  TANK PRESSURE GAUGE: 

The gauge measures the pressure level of the air that is stored in the 

tank. It cannot be adjusted by the operator and it does not indicate the pressure inside the line.

I.  OUTLET PRESSURE GAUGE: 

The gauge measures the regulated outlet pressure.

J.  AIR TANK DRAIN VALVE:

 The drain valve is used to remove moisture from the air tank after the 

compressor is shut off.

 

 

 

WARNING!

 

Do not attempt to open the drain valve when there is more than 

   

10 PSI of air pressure in the tank.

K.  AIR OUTLET:

 The outlet is connected to the 1/4” (6.4 mm) NPT air hose.

KEY

 P

AR

TS

 D

IA

GR

AM

KEY

 P

AR

TS

 L

IS

T

ELECTRIC MOTOR (A)

POWER SWITCH (C)

TANK PRESSURE

GAUGE (H)

OUTLET PRESSURE

GAUGE (I)

AIR OUTLET (K)

POWER CORD (E)

SAFETY 

VALVE (F)

AIR PRESSURE 

REGULATOR (G)

058-7000-2-Air-Compressor-2G-EN-03.indd   7-8

6/11/12   8:14 AM

AIR TANK (D)

Содержание 058-7000-2

Страница 1: ...ughly before using the product It contains important information for your safety as well as operating and maintenance advice Keep this instruction manual for future use Should this product be passed o...

Страница 2: ...5 Plug in the power cord STEP 4 Close the tank drain valve located on the bottom of the air tank TABLE OF CONTENTS QUICK START GUIDE TECHNICAL SPECIFICATIONS 3 SAFETY GUIDELINES 4 6 KEY PARTS DIAGRAM...

Страница 3: ...at may result in moderate injury or damage to equipment IMPORTANT Installation operation or maintenance information that is important but not hazard related Safety Advice DANGER 1 RISK OF FIRE OR EXPL...

Страница 4: ...se and the power cord from damage and puncture Inspect them for weak or worn spots every week and replace them if necessary 4 Always wear hearing protection when using an air compressor Failure to do...

Страница 5: ...ssure from the system when it reaches a preset level if the pressure switch has not shut down the motor It will pop open automatically or it can be activated manually by pulling the ring on the valve...

Страница 6: ...g used again Do not exceed the maximum working time Compatible compressor air tool proper usage operation Always ensure the use of appropriately matched air tools with your Mastercraft Air Compressor...

Страница 7: ...stable wrench 1 Cross headed screwdriver 1 2 Check the air compressor s identification label to ensure that you have purchased the intended model and that it has the required pressure rating for its i...

Страница 8: ...outlet K on the air compressor Hose connector Air outlet K 5 Attach other accessories End of hose or low gun Tire chuck or quick connector Blow gun adaptor Tapered nozzle or inflation needle NOTE Tire...

Страница 9: ...temperatures are generated by the electric motor and the pump To prevent burns or other injuries DO NOT touch the air compressor while it is running Allow it to cool before handling or servicing Keep...

Страница 10: ...ntire unit to protect it from moisture and dust Store the air compressor in a clean and dry location In cold weather store the compressor in a warm building when it is not in use This will reduce prob...

Страница 11: ...d by the compressor a larger capacity air compressor is needed Most accessories are rated at 25 of actual SCFM while running continuously PROBLEM POSSIBLE CAUSES SOLUTIONS The regulator does not regul...

Страница 12: ...flat washer 6 4 11 paper pad 3 36 screw M6 15 4 12 silica gel ring 21 2 1 37 drain valve 1 13 piston ring 1 38 internal tooth washer 1 14 connecting rod 1 39 wire clip 1 15 clamp 1 40 screw M4 15 3 16...

Страница 13: ...This warranty will not apply to any product or part thereof which is worn or broken or which has become inoperative due to abuse misuse accidental damage neglect or lack of proper installation operat...

Отзывы: