background image

15

16

2-GALLON (7.6 L) AIR COMPRESSOR - 058-7000-2

2-GALLON (7.6 L) AIR COMPRESSOR - 058-7000-2

Before each start-up

1.

 

Set the power switch (C) to the 

(off)

 

position.

2.

 

Turn the air pressure regulator knob (G) counter-clockwise until it stops.

3.

 

Attach hose and accessories.

 

WARNING!

 

Risk of bursting. Too much air pressure causes a hazardous risk 

of bursting. Check the manufacturer’s maximum pressure rating for air tools and 
accessories. The regulator outlet pressure must never exceed the maximum pressure 
rating.

How to start

 

WARNING!

 

If the pump has been transported or turned upside down (even 

partially), allow the pump to sit in a normal, upright position for approximately 10 
minutes before starting.

1.

 

Close the tank drain valve (J).

2.

 

Plug in the power cord (E).

3.

 

Set the power switch (C) to the 

(on) position and allow tank pressure to build. Motor will stop 

when tank pressure reaches “cut-out” pressure.

4.

 

Turn the air pressure regulator knob (G) clockwise until desired pressure is reached.

5.

 

The compressor is ready for use.

 

WARNING!

 

High temperatures are generated by the electric motor and the 

pump. To prevent burns or other injuries, DO NOT touch the air compressor while it is 
running. Allow it to cool before handling or servicing. Keep children away from the air 
compressor at all times.

How to shut down

1.

 

Set the power switch (C) to the 

(off) position.

2.

 

Unplug the power cord (E).

3.

 

Reduce the pressure in the tank through the outlet hose. Pulling the safety valve ring (F) and 
keeping it open will also reduce the pressure in the tank.

 

CAUTION!

 

Escaping air and moisture can propel debris that may cause eye 

injury. Wear safety goggles when opening the drain valve.

 

WARNING!

 To avoid personal injury, always shut off and unplug the unit, and 

relieve all air pressure from the system before performing any service on the air 
compressor.

 

WARNING!

 

Risk of unsafe operation. Unit cycles automatically when power 

is on. When performing maintenance, you may be exposed to voltage sources, 
compressed air or moving parts. Personal injuries can occur. Before performing any 
maintenance or repair, disconnect power source from the compressor and bleed off 
all air pressure.

OPE

RA

TI

NG

 INS

TR

UC

TION

S

OPE

RA

TI

NG

 INS

TR

UC

TION

S

058-7000-2-Air-Compressor-2G-EN-03.indd   15-16

6/11/12   8:14 AM

Содержание 058-7000-2

Страница 1: ...ughly before using the product It contains important information for your safety as well as operating and maintenance advice Keep this instruction manual for future use Should this product be passed o...

Страница 2: ...5 Plug in the power cord STEP 4 Close the tank drain valve located on the bottom of the air tank TABLE OF CONTENTS QUICK START GUIDE TECHNICAL SPECIFICATIONS 3 SAFETY GUIDELINES 4 6 KEY PARTS DIAGRAM...

Страница 3: ...at may result in moderate injury or damage to equipment IMPORTANT Installation operation or maintenance information that is important but not hazard related Safety Advice DANGER 1 RISK OF FIRE OR EXPL...

Страница 4: ...se and the power cord from damage and puncture Inspect them for weak or worn spots every week and replace them if necessary 4 Always wear hearing protection when using an air compressor Failure to do...

Страница 5: ...ssure from the system when it reaches a preset level if the pressure switch has not shut down the motor It will pop open automatically or it can be activated manually by pulling the ring on the valve...

Страница 6: ...g used again Do not exceed the maximum working time Compatible compressor air tool proper usage operation Always ensure the use of appropriately matched air tools with your Mastercraft Air Compressor...

Страница 7: ...stable wrench 1 Cross headed screwdriver 1 2 Check the air compressor s identification label to ensure that you have purchased the intended model and that it has the required pressure rating for its i...

Страница 8: ...outlet K on the air compressor Hose connector Air outlet K 5 Attach other accessories End of hose or low gun Tire chuck or quick connector Blow gun adaptor Tapered nozzle or inflation needle NOTE Tire...

Страница 9: ...temperatures are generated by the electric motor and the pump To prevent burns or other injuries DO NOT touch the air compressor while it is running Allow it to cool before handling or servicing Keep...

Страница 10: ...ntire unit to protect it from moisture and dust Store the air compressor in a clean and dry location In cold weather store the compressor in a warm building when it is not in use This will reduce prob...

Страница 11: ...d by the compressor a larger capacity air compressor is needed Most accessories are rated at 25 of actual SCFM while running continuously PROBLEM POSSIBLE CAUSES SOLUTIONS The regulator does not regul...

Страница 12: ...flat washer 6 4 11 paper pad 3 36 screw M6 15 4 12 silica gel ring 21 2 1 37 drain valve 1 13 piston ring 1 38 internal tooth washer 1 14 connecting rod 1 39 wire clip 1 15 clamp 1 40 screw M4 15 3 16...

Страница 13: ...This warranty will not apply to any product or part thereof which is worn or broken or which has become inoperative due to abuse misuse accidental damage neglect or lack of proper installation operat...

Отзывы: