 Not displaying the correct local time and/or date. 

 
Possible reasons/solutions: 

1.

 

The CLDTCD12 has a time zone offset and/or DST offset configured. 

2.

 

Your time code source and/or the CLDTCD12 are set with time zone and/or DST offsets. 

3.

 

Your time code source is not providing the time and/or date that you expect. Contact the 
individual responsible for the time code source for more information. 

 

Clock did not properly negotiate the DST. 

 
Possible reasons/solutions: 

1.

 

Your time code source is not providing date information and/or a valid date was not 
programmed into the CLDTCD12. 

2.

 

Your time code source already provides the DST adjustment. 

3.

 

Your time code source or the CLDTCD12 does not have the correct DST rules configured. 

 

UTC time and/or date is incorrect. 

 
There are several potential failure points: 

 

Invalid, intermittent or missing time code source 

 

Date/year overwrite function for non-date encoded time code may be configured 
improperly 

 

Battery may need to be replaced 

 

A local time zone or DST configuration not set correctly 
 

1.

 

Verify that your time code source is generating the UTC referenced time and date that you 
expect and that this time code format is at an acceptable signal level and quality that can 
be detected at the client side (i.e. CLDTCD12 input). 

2.

 

When using SMPTE time code, verify that you are not using drop frame time code. Use 
only NDF (non-drop frame) SMPTE time code. 

3.

 

If you are using in-house time code, verify that the time code source is locked to the GPS 
satellite system for UTC time code. Time code sources such as SMPTE time code that is fed 
via a broadcast satellite will have a delay due to the satellite transmission. The CLDTCD12 
cannot compensate for satellite transmission delays. 

4.

 

If you are using a time code source from another vendor, be certain your time code 
contains encoded year/date information to the VITC or SMPTE time code encoding 
formats. SMPTE-type time codes must have the date be encoded to the specification in the 
user bits. 

5.

 

If your time code source is providing DST adjustments and time zone offsets these 
functions must be disabled in your CLDTCD12 in order to eliminate double offsets. 

If you are using the date/time display such as on a Windows system to validate the time on the 
clock, this may provide misleading information as these may be configured to display local time 
zone and daylight saving time information and they may not be currently synchronized to UTC 
time. This is configured through the Date/Time applet in the Control Panel.

 

 

Содержание CLDTCD12

Страница 1: ...Masterclock www masterclock com 1...

Страница 2: ...ll find this user manual will handle virtually all of your questions Disclaimer The material in this document is for information only and subject to change without notice While reasonable efforts hav...

Страница 3: ...k and white bars in a video signal These lines are typically inserted into the vertical blanking interval of the video signal There can be more than one VITC pair in a single frame of video this can b...

Страница 4: ...f Motion Picture and Television Engineers format is available in frame rates of 24 25 and 30 frames second The CLDTCD12 time code clock supports all three formats All formats of SMPTE time code decode...

Страница 5: ...sterclock product or attempt to disassemble or modify it Never insert any metallic object into the clocks case doing so increases the risk of electrical shock short circuiting fire or personal injury...

Страница 6: ...m RG59 coaxial cable not included to the BNC connector located on the back panel Balanced Signal Secure the wires not included to the terminal block located on the back panel USB Port For configuratio...

Страница 7: ...cess the back of the clock Do not route power or signal cables between the case and the wall along the exterior of the wall which may pinch the power or signal cable and create a hazardous condition W...

Страница 8: ...Masterclock www masterclock com 8 Wall Mount Dimensions...

Страница 9: ...Masterclock www masterclock com 9 CLDTCD12 Dimensions...

Страница 10: ...st power on the CLDTCD12 Next use a USB cable not supplied and connect to the PC The Windows Plug and Play manager will detect a new USB device and request device drivers If Windows is unable to insta...

Страница 11: ...Discover all devices accessible on the network will announce their presence and the status bar will display the count of devices found When complete a list of device families and groups will be displ...

Страница 12: ...r a unique password for every device to change the factory default password public A password is one to eleven characters and is case sensitive For added password strength you should use a combination...

Страница 13: ...Last Time Lock Lost UTC and Last Time Lock Restored UTC Below is a Time Code Reader tab The first lists the name and model number of the unit followed by the network configuration numbers These would...

Страница 14: ...ose SMPTE and IRIG Code Settings or VITC Encoding The Time Code Reader button and window are detailed on page 13 The Display Properties button and window at left permits the user to change the brightn...

Страница 15: ...client is disabled or when a network connection to an Time Code server is not available SET PASSWORD See page 9 INSTALL NEW OPTION Paste the Option Key you receive here LEAP SECOND DATE Manually ente...

Страница 16: ...m VITC the clock will display time from a SMPTE Time Code source once you have configured input From the Input Control select Time Code Reader and select from the SMPTE Time Code Setting Options inclu...

Страница 17: ...the clock will display time from an IRIG Time Code once you have configured IRIG input From the Input Control select Time Code Reader and check box from within the IRIG Time Code Settings This will s...

Страница 18: ...k By switching to VITC from LTC the clock will display time from a video source once you have configured VITC input From the Input Control select Time Code Reader and select from the VITC Encoding dro...

Страница 19: ...and click OK to close the window Changes are applied when you click OK Daylight Saving Time Configure and or enable the daylight saving function by clicking the Daylight Saving Time button North Amer...

Страница 20: ...this window control how the clock displays time date and level of brightness Display Properties configurations will be applied after you click OK and then click Apply from the main window Set Date Ti...

Страница 21: ...ected the CLDTCD12 will continue to display time based on its internal reference until the time code signal is returned The colons of the clock display will flash when the time displayed is not locked...

Страница 22: ...name The name is arbitrary and may be useful for organizing and managing devices once installed By default device names are the product name abbreviation followed by the device s MAC address Customers...

Страница 23: ...Time Code with precision TCXO AND RTC CIRCUIT The CLDTCD12 contains a precision TCXO Temperature Compensated Crystal Oscillator and RTC Real Time Clock circuit allowing the clock to maintain an accura...

Страница 24: ...ML1220 V1A Rechargeable Manganese Lithium coin cell Panasonic ML1220 and recharging circuit requires no maintenance and retains all configuration settings for two weeks minimum holdover without applie...

Страница 25: ...ng automatic detection and automatic gain adjustment Impedance 50 K Nominal Level 1 5 Vpp 0dB 600 Input Level Range 0 175 12 Vpp 15dBV to 20dBV Auto Detection Gain Adjustment Range IRIG B00 un modulat...

Страница 26: ...user serviceable parts inside the CLDTCD12 digital clock display Please contact MASTERCLOCK if you require servicing or repair Clock is displaying dashes and or colon s are flashing i e unable to lock...

Страница 27: ...that this time code format is at an acceptable signal level and quality that can be detected at the client side i e CLDTCD12 input 2 When using SMPTE time code verify that you are not using drop frame...

Страница 28: ...clock has a stainless steel case a cleaner and polish designed for use on stainless steel is recommended Use a recommended product to maintain and protect the stainless steel finish while resisting w...

Страница 29: ...se abrasive or highly alkaline cleaners Don t use paper towels paper products rayon or polyester cloths to clean or dry the lens Don t scrape the lens with squeegees razor blades or other sharp instru...

Страница 30: ...er customer supplied software or interfacing unauthorized modification or misuse operation outside of the environmental specifications for the product or improper site preparation and maintenance if a...

Страница 31: ...horized to carry out maintenance on this device Read this User s Manual carefully and follow the correct procedure when setting up the device Do not open your Masterclock product or attempt to disasse...

Страница 32: ...g and Control Instruments Equipment as defined by the WEEE Directive and therefore fall within the scope of the WEEE Directive RoHS Compliant by Exemption Restriction of the Use of Certain Hazardous S...

Страница 33: ...est service in the fastest manner We apologize for any inconvenience that the need for repair may cause you We hope that our rapid service meets your needs If you have any suggestions to help us impro...

Страница 34: ...Masterclock www masterclock com 34...

Отзывы: