4.

 

Transfer Individual to the Tub Lift 

a.

 

Push  down  on  the  Open  Door  Button 

until the door is fully opened and stops 

on its own.  

b.

 

Position the comfort pad group in the Lift 

Chair  as  follows;  two  rectangular  pads 

parallel about three to four inches apart 

centered  in  the  individual  seating  area, 

one rectangular pad horizontally on the 

seat  back  at  approximately  the  lumbar 

area of the individual 

 

c.

 

Transfer  the  individual  to  the  Lift  Chair 

using  appropriate  ergonomic  transfer 

techniques or with a modern lift/transfer 

device  per  facility  protocol  (See 

Adjusting  the  Entree  Tub  For 

Lift/Transfer Devices

 on page 30)  

d.

 

Position the security belt attached to the 

connecting knobs on the lift chair having 

one  belt  crossed  diagonal  from  one 

shoulder  to  the  opposite  side  hip  and 

another  belt  connecting  the  knobs  on 

each  side  of  the  lap. 

(See  the  Belting 

Diagram)

 

 

 

Comfort Pads Position 

Open Door 

Button 

Comfort Pads 

Lift Bar 

Security Knob 

Security Knob 

Security Knob 

Содержание Entree Bath Gen III MB-68 AV-XL

Страница 1: ...B 68 AV XL INSTALL CHECK LIST USER MANUAL Important Safety Instructions Read Follow All Instructions Thoroughly Important safety instructions Read and follow all instructions thoroughly CAUTION The ca...

Страница 2: ...ARIABLE SPEED SYSTEM 19 Operation 21 Bathing Procedures 21 Cleaning Procedures 28 BathAire SM Purge Cycle 29 Adjusting the Entree Tub For Lift Transfer Devices 30 EMERGENCY OPEN CLOSE DOOR PROCEDURES...

Страница 3: ...provided backflow prevention is the most widely accepted Local codes may require changes The local plumbing contractor is responsible for any changes BathAire SM Outlets 4 with 12 ports each for a tot...

Страница 4: ...Shipping Weight Approximately 1 000 lbs Fill Rate In excess of 17 GPM provided that the water lines are water pressure is at least 60 psi and the hot water is 120 F Facility and or other environmental...

Страница 5: ...I MODEL MB 68 AV XL 10 20 19 Page 5 of 51 450 E 32nd Ave Fremont NE 68025 800 798 5867 FAX 402 721 3023 www mastercarebath com PLUMBING ELECTRICAL ROUGH IN INFORMATION TUB ANCHORING INFORMATION Placem...

Страница 6: ...ollow All Instructions Thoroughly Important safety instructions Read and follow all instructions thoroughly CAUTION The caution heading identifies important maintenance and operation information Failu...

Страница 7: ...NE 68025 800 798 5867 FAX 402 721 3023 www mastercarebath com BEFORE STARTING TOOLS NEEDED FOR INSTALLATION Adjustable Wrench Tape Measure Channel Locks Deep and 9 16 Deep Socket and Ratchet 2 Philli...

Страница 8: ...32nd Ave Fremont NE 68025 800 798 5867 FAX 402 721 3023 www mastercarebath com ENTR E GEN III LOCATION REFERENCE v Console Service Access Chair Foot End Controls TOP VIEW OF TUB Back of the Top Front...

Страница 9: ...screws from the bottom of the crate Detail 1 3 Two people will now be required to lift the crate over the top of the Entree Bath 4 Set aside the Entree Gen III Starter Kit box and the Combo Case from...

Страница 10: ...2nd Ave Fremont NE 68025 800 798 5867 FAX 402 721 3023 www mastercarebath com ENTREE TUB CRATE REMOVAL IMPORTANT IMMEDIATELY UPON RECEIPT CHECK FOR VISIBLE FREIGHT DAMAGE IF DAMAGE IS FOUND IT MUST BE...

Страница 11: ...or its test operation Check again to make sure the door is not fully closed and compressing the seal 4 Connect the electrical service to the tub The tub comes with a cord with a plug or it can be hard...

Страница 12: ...rvice B Wall Drain Option A Floor Drain Option 40 1 2 Rear Wall Casual Water Drain Hose 19 SIDE VIEW OF DRAIN CAUTION Plumbing and electrical installations must be clear of the full rotational arc of...

Страница 13: ...INSTALLATION MANUAL 10 20 19 Page 13 of 51 450 E 32nd Ave Fremont NE 68025 800 798 5867 FAX 402 721 3023 www mastercarebath com 13 Tighten the hose clamps on the rubber couplers 14 Anchor the tub to...

Страница 14: ...alve Check the water temperature and verify it is in the proper range Rotate the knob to mid range and verify the temperature tracks the knob and reduces accordingly Note If the hoses are connected ba...

Страница 15: ...ATION MANUAL 10 20 19 Page 15 of 51 450 E 32nd Ave Fremont NE 68025 800 798 5867 FAX 402 721 3023 www mastercarebath com 20 Make sure the Casual Water Drain located in the back side of the tub is prop...

Страница 16: ...low All Instructions Thoroughly Important safety instructions Read and follow all instructions thoroughly CAUTION The caution heading identifies important maintenance and operation information Failure...

Страница 17: ...r dryer lamp telephone radio or television within 5 ft 1 5m of the hydromassage bathtub Proper electrical grounding must be performed by a licensed electrician following local state and federal codes...

Страница 18: ...ain water sensors Door Open Close Button To open door press and hold down the Door Open Button until the door comes to a complete stop To close the door press and hold down the transmitter close butto...

Страница 19: ...The BathAire SM starts on at 60 of full volume To increase or decrease the air volume press the air heat button and hold down to increase level or the air heat button to decrease level until the desir...

Страница 20: ...Button In case of emergency this will stop the Lift motion overriding the Hand Lift Control Only raise or rotate the Lift when the resident is properly secured with the belts CAUTION Only lower your L...

Страница 21: ...hes the desired temperature adjust the water temperature between 96 to 105 by turning the Mixing Valve toward the hot or cold side Turn off the Shower Spray Control Valve and replace the Shower Spray...

Страница 22: ...r to turning on the BathAire SM remove the Aromatherapy Cap that is placed under the Dispensing Box Access Door place selected scent cartridge or sachet in the Aromatherapy Cartridge Holder and secure...

Страница 23: ...ectangular pad horizontally on the seat back at approximately the lumbar area of the individual c Transfer the individual to the Lift Chair using appropriate ergonomic transfer techniques or with a mo...

Страница 24: ...ime you weigh someone you will help assure getting an accurate weight CAUTION Do not push LB KG and ON ZERO buttons at the same time Push all buttons with finger only No pens or sharp objects 6 Transf...

Страница 25: ...owing the above instructions if needed e If manual fill is desired set the Rapid Fill Control of the Console Controls to Tub Fill while monitoring the Reservoir Water Thermometer f Fill to 2 4 below t...

Страница 26: ...pen position Allow the tub to drain completely before opening the door Note Sensors in the tub will prevent the Open Door button from functioning while there is water in the tub Make sure tub is compl...

Страница 27: ...as indicated rotate the Lift out of the tub until it is fully out Then press the Down Button in the Hand Lift Control until it is at its lowest position CAUTION Failing to bring the Lift to its fully...

Страница 28: ...rotating it in a clockwise direction until it is fully off 7 Scrub all areas with the long handled brush provided with the tub After all areas are thoroughly scrubbed follow rinsing procedures below...

Страница 29: ...r Bath Oil and Shampoo solutions used during the bathing procedures must be stored in a secure area not accessible by the patients It is recommended that a two person bathing team be established for e...

Страница 30: ...fer device is needed 1 Push down on the Door Open Button allowing the door to rotate to a fully open position until it stops on its own 2 Remove the Kick Panel by removing the two thumb screws at eith...

Страница 31: ...the door before the tub is totally empty hold Emergency Door Open Button and the Door Open Button at the same time to open the door It will overwrite the drain water sensors In the event there is a p...

Страница 32: ...Circuit Interrupter detects and interrupts electric faults to insure safety to allindividuals Reset Button trips and shuts down all power should a power surge outage faulty outlet lightening etc have...

Страница 33: ...the suction cups are clean Wetting the suction cups before attachment will make them adhere better 3 Arrange the comfort pads as shown above with two pads parallel on the seat and one against the sea...

Страница 34: ...NOT advised to use conditioners on the pads and straps Disinfect the pads and straps with MasterCare Disinfectant according to the label and thoroughly rinse with water Rotating the pads on a daily ba...

Страница 35: ...s obtained the weight will be displayed for 5 seconds with a single digit precision rounded to 0 5 Measurement units can be changed using the lb kg key Exception or errors If tare weight is removed or...

Страница 36: ...ress and hold the Recall key until 0000 is shown on the display 6 Make sure that no weight is present on the scale platform 7 Press the Recall key to save the zero weight calibration point 8 Use the U...

Страница 37: ...Adjust Mixing Valve To Desired Temperature Fill Tub with Tub Fill Valve Use Liquids As Desired Use Shower Wand With Shower Wand Control Valve Open Drain With Open Close Lever After Water Is Drained O...

Страница 38: ...llow All Instructions Thoroughly Important safety instructions Read and follow all instructions thoroughly CAUTION The caution heading identifies important maintenance and operation information Failur...

Страница 39: ...Same as monthly Plumbing and drain assembly Check all fittings and connections to make sure they are secure and no leaks have developed Check with a hand held thermometer and observe the solar thermom...

Страница 40: ...the BathAire SM is in use but the cycle will be available to use in the bath when the Purge cycle is finished Mechanical Membrane switch defective BathAire SM aerator out of adjustment Flexible air t...

Страница 41: ...rect check and clean the valve o The check valve in the 2 PVC drain pipe is located too high above the level of the hose barb in the door when the door is rotated to a full closed position To correct...

Страница 42: ...Entr e Bath Gen III MODEL MB 68 AV XL MAINTENANCE MANUAL 10 20 19 Page 42 of 51 450 E 32nd Ave Fremont NE 68025 800 798 5867 FAX 402 721 3023 www mastercarebath com...

Страница 43: ...Y 1 102920 WIRE TIE 8 11 2 210177 CG AIR FG CONTROL SHELF 1 3 40020 BLOWER SILVER NON ELECTRONIC 1 4 40012 CONTROL COMFORT WARM 1 5 40016 CONTROL UNIVERSAL UNIT 1 6 40028 LATCH FRONT HEAVY DUTY LH SS...

Страница 44: ...ng a Phillips screwdriver loosen all seal retainer bolts as shown in Fig 3 DO NOT remove the bolts 10 Remove the seal by gently pulling on one end until the entire seal is removed Note If the seal is...

Страница 45: ...tr e Bath Gen III MODEL MB 68 AV XL MAINTENANCE MANUAL 10 20 19 Page 45 of 51 450 E 32nd Ave Fremont NE 68025 800 798 5867 FAX 402 721 3023 www mastercarebath com ENTREE DOOR SEAL DIAGRAM DO NOT REMOV...

Страница 46: ...e lower lip of the fiber glass door cover It should be inspected annually and replaced if worn or deteriorated To install 1 Open door from a closed position until diverter seal to be replaced just cle...

Страница 47: ...ll be primed and glued using PVC primer and glue per MasterCare best practices 2 Pipe thread fittings shall be properly prepared with Teflon tape and or paste and tightened in accordance with MasterCa...

Страница 48: ...d cold water supply before the replacing the cartridge 25 Using a utility knife gently pry off the cap 6 that is located on top of the thermostatic control valve handle 7 26 Using a Philips screwdrive...

Страница 49: ...25 800 798 5867 FAX 402 721 3023 www mastercarebath com GEN II MIXING VALVE DIAGRAM ITEM NO DESCRIPTION QTY 1 THERMOSTATIC VALVE 1 2 CARTRIDGE REPLACE THERMOSTATIC 1 3 O RING 3 4 HUB 1 5 SETTING RING...

Страница 50: ...de 2 Loosen the strain relief Remove the 1 8 tubing from the chrome raised transmitter to be replaced 3 Using large pliers loosen and remove the plastic nut from the bottom of the chrome raised transm...

Страница 51: ...19 Page 51 of 51 450 E 32nd Ave Fremont NE 68025 800 798 5867 FAX 402 721 3023 www mastercarebath com FOR ADDITIONAL MAINTENANCE HELP OR TO PLACE AN ORDER Online www mastercarebath com Email masterca...

Отзывы: