Entrée Bath Gen III -
MODEL MB-68 AV-XL
INSTALLATION MANUAL
10-20-19
Page 11 of 51
450 E 32
nd
Ave – Fremont, NE 68025
800-798-5867 FAX: 402-721-3023
www.mastercarebath.com
3.
Transfer and Positioning:
The tub is shipped with the door in the open position. To transfer, plug the tub into an
extension cord and rotate the door to a nearly closed position, by pushing on the Door Close button until the
door rotates all the way up and it just starts to cam in.
CAUTION
: Do not close the door all the way so that the seal is compressed. Leaving the door closed with
the seal compressed over a long period of time can damage the seal.
The tub may have to be in an open position to get through some doors. After the tub is on-site, leave the special
packing around the tub door on until after the tub is installed and ready for its test operation. Check again to
make sure the door is not fully closed and compressing the seal.
4.
Connect the electrical service to the tub.
The tub comes with a cord with a plug, or it can be hard wired with flex
watertight conduit by an electrician.
(Verify that the tub is properly grounded if rewired
5.
Flush line into a
bucket and verify hot water comes from that hose. After flushing, attach tub hose with red
marking.
6.
Make sure the screen is in the hose.
7.
Connect a flexible hose to the hot water supply valve.
8.
Flush hose into a
bucket and verify cold water comes from hose. After flushing, attach tub hose with blue marking.
Note: The mixing valve will not perform correctly if those hoses are connected backwards.
9.
Make sure the screen is in the hose.
10.
Connect a flexible hose to the cold water supply valve.
11.
Turn on the hot and cold supply valves
slowly and verify there are no leaks.
12.
Place the tub in the final desired location and connect the drain
tubing as shown in the following figure.