►►8. DISPLAY ERRORS
See B Fig. 3
ERROR
CAUSE
SOLUTION
F0
OPERATION ERROR
1. The “ON/OFF” switch is turned
“ON” (|) when the heater is plugged
in
1. After disconnecting the heater, see that
the switch is in the “OFF” (0) position,
plug the heater in and turn the switch
“ON” (|)
F1
PHOTOCELL ERROR
1. No fuel
2. Fuel is contaminated
3. Photocell is dirty or damaged
4. Fuel filter is dirty
5. Ignition error
1. Turn the switch “OFF” (0), refill the fuel
tank
2. Turn the switch “OFF” (0) empty and
refill the fuel tank. Clean the filter using
clean fuel, do not damage the filter (SEE
PARA. 6)
3. Contact the technical service center
4. SEE PARA. 6
5. Contact the technical service center
F2
TEMPERATURE CONTROL SENSOR ERROR
1. Interrupted cable
2. Sensor is damaged
1. Contact the technical service center
2. Contact the technical service center
F3
THERMOSTAT ERROR
1. Internal heater overheating
2. Antitilting sensor intervent
1. Turn the heater off, wait until it is cooled
down
2. Place the heater on a level and stable
surface
F4
INCORRECT VOLTAGE
1. Incorrect voltage
1. Check voltage of your electric supply
system
FF
NO SWITCH-ON AFTER THREE ATTEMPTS
1. No fuel
2. Dirty fuel filter
3. Dirty or defective photocell
4. Dirty or defective nozzle
5. Anti-tilting sensor trip
1. Contact the technical service center
2. Contact the technical service center
3. Contact the technical service center
4. Contact the technical service center
5. Contact the technical service center