10
16. FABRIC TENSION
N° of movements
Setting
1
2
*
3
4
Minimum tension
+
++
Maximum tension
*
factory setting
18. AUTOZERO MODE
All rights reserved. All products and technical specifications given in this document are subject to variation without notice.The manufacturer shall not be liable for damage resulting from improper, incorrect or
unreasonable use.
10.1 UTILIZZANDO IL TRASMETTITORE (solo Atom e Leg)
ARCO
FLUTE, KUADRO, KORT
VISIO
Other transmitters...
01. Bring the motor in an intermediate position
02. Press MENU for about 5 sec, until «rS»
appears on display
03. Press 1 time PREV / 4 times NEXT.
«14» appears on display
04. Press STOP. The motor signals the current
value (1 to 4 movements)
05. Press NEXT the number of times equal to
the desired setting (1 to 4)
06. Press STOP. The motor signals the new
value (1 to 4 movements)
01. Bring the motor in an intermediate position
02. Holding down STOP, press PROG for
about 1 sec, until LEDs light
03. Press 1 time UP / 4 times DOWN.
04. Press STOP. The motor signals the current
value (1 to 4 movements)
05. Press DOWN the number of times equal to
the desired setting (1 to 4)
06. Press STOP. The motor signals the new
value (1 to 4 movements)
01. Bring the motor in an intermediate position
02. Press MENU, «Menu rx» appears on
display
03. Press 1 time PREV / 4 times NEXT.
«14» appears on display
04. Press STOP. The motor signals the current
value (1 to 4 movements)
05. Press UP the number of times equal to the
desired setting (1 to 4)
06. Press STOP. The motor signals the new
value (1 to 4 movements)
See the User manual of
the transmitter at
section:
«RECEIVER MENU -
Function 14»
It allows to set the tension to be exerted on the fabric. It is possible to choose between 4 levels (1 =
minimum tension, ..., 4 = maximum tension). The factory sets the parameter at level 2.
17. OBSTACLE ON DOWNWARD
Necessary condition for the proper operation of this feature is the use of the offset adapter, properly installed (see section
03 "Installing the offset adapters"). When the obstacle is detected, the motor stops the manoeuvre and makes a large
upward movement to allow the obstacle to be removed. The motor is able to detect obstacles such as to stop the terminal
bar almost instantaneously, obstacles that gradually slow down the terminal bar may not be detected.
Setting 1
: "Function inactive". Choose this setting if the drop awning does not slide well in the guides, to prevent the motor
from detecting non-existent obstacles. In this case, the factory also recommends checking the installation of the drop
awning.
Setting 2-4
: "Minimum sensitivity - average - maximum". Choose according to the desired reactivity. The factory sets the
parameter at level 3 (average sensitivity). Use level 4 (maximum sensitivity) only if the sliding of the drop awning is optimal.
10.1 UTILIZZANDO IL TRASMETTITORE (solo Atom e Leg)
ARCO
FLUTE, KUADRO, KORT
VISIO
Other transmitters...
01. Bring the motor in an intermediate position
02. Press MENU for about 5 sec, until «rS»
appears on display
03. Press 1 time PREV / 3 times NEXT.
«13» appears on display
04. Press STOP. The motor signals the current
value (1 to 4 movements)
05. Press NEXT the number of times equal to
the desired setting (1 to 4)
06. Press STOP. The motor signals the new
value (1 to 4 movements)
01. Bring the motor in an intermediate position
02. Holding down STOP, press PROG for about
1 sec, until LEDs light
03. Press 1 time UP / 3 times DOWN.
04. Press STOP. The motor signals the current
value (1 to 4 movements)
05. Press DOWN the number of times equal to
the desired setting (1 to 4)
06. Press STOP. The motor signals the newt
value (1 to 4 movements)
01. Bring the motor in an intermediate position
02. Press MENU, «Menu rx» appears on
display
03. Press 1 time PREV / 3 times NEXT.
«13» appears on display
04. Press STOP. The motor signals the current
value (1 to 4 movements)
05. Press UP the number of times equal to the
desired setting (1 to 4)
06. Press STOP. The motor signals the new
value (1 to 4 movements)
See the User manual of
the transmitter at
section:
«RECEIVER MENU -
Function 13»
*factory setting
*factory setting
N° of movements
Setting
1
2
3
*
4
Not active function
Minimum sensitivity
Medium sensitivity
Maximum sensitivity
If the upper limit switch is stored for contact with an upper stop, you can decide whether the motor must
always reach the upper stop (setting 1 "no release"), if the motor must always reach the upper stop and drop
the fabric briefly (setting 2 "with release"), or if the motor must stop a few inches before the upper stop and
only occasionally (every 30 upward manoeuvres ) reach it (setting 3 «
Upper stop every 30 manoeuvres, with
release
"). In any case, each time the motor reaches the upper stop, the stroke is recalibrated in order to
recover any shortening / lengthening of the fabric. The factory set this parameter to 2 (autozero "with
release").
N° of movements
Setting
1
2
*
3
No release
With release
Upper stop every
30 manoeuvres, with release
10.1 UTILIZZANDO IL TRASMETTITORE (solo Atom e Leg)
ARCO
FLUTE, KUADRO, KORT
VISIO
Other transmitters...
01. Bring the motor in an intermediate position
02. Press MENU for about 5 sec, until «rS»
appears on display
03. Press 1 time PREV / 1 times NEXT.
«11» appears on display
04. Press STOP. The motor signals the current
value (1 to 3 movements)
05. Press NEXT the number of times equal to
the desired setting (1 to 3)
06. Press STOP. The motor signals the new
value (1 to 3 movements)
01. Bring the motor in an intermediate position
02. Holding down STOP, press PROG for about
1 sec, until LEDs light
03. Press 1 time UP / 1 times DOWN.
04. Press STOP. The motor signals the current
value (1 to 3 movements)
05. Press DOWN the number of times equal to
the desired setting (1 to 3)
06. Press STOP. The motor signals the newt
value (1 to 3 movements)
01. Bring the motor in an intermediate position
02. Press MENU, «Menu rx» appears on
display
03. Press 1 time PREV / 3 times NEXT.
«11» appears on display
04. Press STOP. The motor signals the current
value (1 to 3 movements)
05. Press UP the number of times equal to the
desired setting (1 to 3)
06. Press STOP. The motor signals the new
value (1 to 3 movements)
See the User manual of
the transmitter at
section:
«RECEIVER MENU -
Function 11»
19. DISTANCE FROM MECHANICAL STOP
This function is available only if the upper limit switch has been learned by contact with a mechanical stop.
In this case, the motor will stop a few centimeters from the mechanical stop (only occasionally it will look for the stop to
automatically recalibrate the stroke). This parameter allows you to set the distance between the stop point and the
mechanical stop.
The factory sets the parameter at level 2.
N° of movements
Setting
1
2 - 3 - 4 - 5 - 6 - 7- 8
*
9
Minimum distance
Intermediate distances
Maximum distance
*
factory setting
Other transmitters...
See the User manual of
the transmitter at
section:
«RECEIVER MENU -
Function 08»
10.1 UTILIZZANDO IL TRASMETTITORE (solo Atom e Leg)
ARCO
FLUTE, KUADRO, KORT
VISIO
01. Bring the motor in an intermediate position
02. Press MENU for about 5 sec, until «rS»
appears on display
03. Press 8 times NEXT.
«08» appears on display
04. Press STOP. The motor signals the current
value (1 to 9 movements)
05. Press NEXT the number of times equal to
the desired setting (1 to 9)
06. Press STOP. The motor signals the new
value (1 to 9 movements)
01. Bring the motor in an intermediate position
02. Holding down STOP, press PROG for about
1 sec, until LEDs light
03. Press 8 times DOWN.
04. Press STOP. The motor signals the current
value (1 to 9 movements)
05. Press DOWN the number of times equal to
the desired setting (1 to 9)
06. Press STOP. The motor signals the newt
value (1 to 9 movements)
01. Bring the motor in an intermediate position
02. Press MENU, «Menu rx» appears on
display
03. Press 8 times NEXT.
«08» appears on display
04. Press STOP. The motor signals the current
value (1 to 9 movements)
05. Press UP the number of times equal to the
desired setting (1 to 9)
06. Press STOP. The motor signals the new
value (1 to 9 movements)