06.2 LOWER LIMIT SWITCH BY PRESSURE - UPPER LIMIT SWITCH BY NO PRESSURE
*
05
ON
1-
Connect the power supply
2-
Bring the roll-up shutter in a intermediate position
3-
Move briefly the roll-up shutter downward
4-
Press together UP and DOWN until the motor makes two alternate
movements (circa 5 secondi), then release the buttons
5-
Press and hold DOWN until the motor stops automatically on the
lower limit switch by pressure
6-
Bring the motor to the desired upper limit switch
7-
Press together UP and DOWN until the motor makes two alternate
movements (circa 5 secondi), then release the buttons.
06.3 LOWER LIMIT SWITCH BY NO PRESSURE - UPPER LIMIT SWITCH BY PRESSURE
*
ON
1-
Connect the power supply
2-
Bring the roll-up shutter in a intermediate position
3-
Move briefly the roll-up shutter downward
4-
Press together UP and DOWN until the motor makes two alternate
movements (circa 5 secondi), then release the buttons
5-
Bring the motor to the desired lower limit switch
6-
Press together UP and DOWN until the motor makes two alternate
movements (circa 5 secondi), then release the buttons
7-
Press and hold UP until the motor stops automatically on the upper
limit switch by pressure
(*)
until the installation procedure is finished, the movement of the motor is preceded by a small click
(*)
until the installation procedure is finished, the movement of the motor is preceded by a small click
NOTE: to optimize the behavior near the upper limit switch, read section 09 "Early stop" and 10 "Close pressure»