12
102331
Air Output, Air Intake,
and Lint Filters
1. Remove upper shell (see
page 10).
2. Remove filter end cover
screws using 5/16" nut-
driver.
3. Remove filter end cover.
4. Replace air output and lint
filters.
5. Wash or replace air intake
filter (see Preventative
Maintenance Schedule,
page 8).
6. Replace filter end cover.
7. Replace fan guard and
upper shell.
IMPORTANT:
Do not oil
filters.
Figure 14 - Air Output, Air Intake, and Lint Filters (BJA70B and BJB70B)
Air Intake Filter
Filter End
Cover
Lint Filter
Air Output
Filter
Figure 15 - Air Output, Air Intake, and Lint Filters
(BJA100C, BJB100C, and BJ150)
Figure 16 - Pressure Gauge Plug Removal
Figure 17 - Adjusting Pump Pressure
Pump
Model
Pressure (PSI)
BJA70B
4.0
BJB70B
4.0
BJA100C
4.0
BJB100C
4.5
BJ150
5.0 @ 50Hz
5.3 @ 60Hz
Pump Pressure
Adjustment
1. Remove pressure gauge
plug from filter end cover.
2. Install accessory pressure
gauge (part number
HA1180).
3. Start heater (see Operation,
page 7). Allow motor to
reach full speed.
4. Adjust pressure. Turn relief
valve to right to increase
pressure. Turn relief valve
to left to decrease pressure.
See specifications at right
for correct pressure for
each model.
5. Remove pressure gauge.
Replace pressure gauge
plug in filter end cover.
Fan Guard
Air Intake Filter
Lint Filter
Filter End
Cover
Air Output
Filter
Pressure
Gauge
Relief
Valve
Pressure
Gauge
Plug