15
102331
BJB70B
BJA70B
BJB100C
BJA100C
BJ150
Heat Output
(Kcal/hr)
16,500
16,500
22,000
24,000
38,000
Fuel Consumption
(liters/hr)
2.0
2.0
2.6
2.9
4.2
Fuel Tank Capacity
(liters)
16
16
32
32
47
Run Time per Tank
(hours)
8
8
12
11
11
Hot Air Output
(m
3
/min)
7.1
7.1
10.9
12.0
12.4@50Hz
13.7@60Hz
Voltage
100
100
100
100
100
Frequency (Hz)
50
60
50
60
50/60
Wattage (W)
190
200
240
260
300
Pump Pressure
(kg/cm)
0.28
0.28
0.32
0.28
0.35@50Hz
0.37@60Hz
(PSI)
4.0
4.0
4.5
4.0
5.0@50Hz
5.3@60Hz
Fan
IMPORTANT:
Remove fan
from motor shaft before
removing motor from heater.
The weight of the motor
resting on the fan could
damage the fan pitch.
1. Remove upper shell (see
page 10).
2. Use 1/8" allen wrench to
loosen setscrew which
holds fan to motor shaft.
3. Slip fan off motor shaft.
4. Clean fan using a soft cloth
moistened with kerosene or
solvent.
5. Dry fan thoroughly.
6. Replace fan on motor
shaft. Place fan hub flush
with end of motor shaft
(see Figure 25).
7. Place setscrew on flat of
shaft. Tighten setscrew
firmly (40-50 inch-pounds/
4.5-5.6 n-m).
8. Replace fan guard and
upper shell.
SPECIFICATIONS
Figure 25 - Fan Cross Section
Setscrew
Motor
Shaft
Fan
Flush
Motor
Shaft
Setscrew
Fan