background image

6

105398

PORTABLE FORCED AIR HEATERS

R

STORING,
TRANSPORTING,
OR SHIPPING

Note: 

If shipping, transport companies re-

quire fuel tanks to be empty.

1.

Drain fuel tank.

Note: 

Some models have drain plug on

underside of fuel tank. If so, remove
drain plug to drain all fuel. If heater
does not have drain plug, drain fuel
through fuel cap opening. Be sure all
fuel is removed.

2.

Replace drain plug if provided.

3.

If any debris is noted in old fuel, add 1
or 2 quarts of clean kerosene to tank,
stir, and drain again. This will prevent
excess debris from clogging filters dur-
ing future use.

4.

Replace fuel cap or drain plug. Prop-
erly dispose of old and dirty fuel. Check
with local automotive service stations
that recycle oil.

5.

If storing, store heater in dry place.
Make sure storage place is free of dust
and corrosive fumes.

IMPORTANT:

 Do not store kerosene over

summer months for use during next heating
season. Using old fuel could damage heater.

PREVENTATIVE
MAINTENANCE
SCHEDULE

How To

See Storing, Transporting, or Ship-
ping

See Air Output, Air Intakeand Lint
Filters
, page 10

See Air Output, Air Intakeand Lint
Filters
, page 10

See Fuel Filter, page 8

See Fan, page 13

 WARNING: Never service heater

while it is plugged in, operating, or hot.
Severe burns and electrical shock can
occur.

Item

Fuel tank

Air output and
lint filters

Air intake filter

Fuel filter

Ignitor

Fan blades

Motor

How Often

Flush every 150-200 hours of
operation or as needed

Replace every 500 hours of
operation or once a year

Wash and dry with soap and
water every 500 hours of op-
eration or as needed

Clean twice a heating season
or as needed

No maintenance required

Clean every season or as
needed

Not required/permanently lu-
bricated

REMEDY

1. Check all electrical connections. See

Wiring Diagram, page 23

2. If fan does not turn freely, see Pump

Rotor, page 12

3. Replace ignition control assembly
4. Replace motor

POSSIBLE CAUSE

1. Bad electrical connection between motor

and ignition control assembly or ignition
control assembly and power cord

2. Binding pump rotor

3. Defective ignition control assembly
4. Defective motor

TROUBLESHOOTING

 WARNING: Never service heater while it is plugged in, operating, or

hot. Severe burns and electrical shock can occur.

 WARNING: High voltage!

FAULT CONDITION

Motor does not start five seconds after heater
is plugged in (ON/OFF switch light remains
on)

HEATER WITH FUSED OR NON-FUSED IGNITION CONTROL ASSEMBLY

Содержание B100CEL

Страница 1: ...ing start ing or servicing heater Improper use of heater can cause serious injury Keep this manual for future reference R Heater Sizes 35 000 70 000 100 000 150 000 Btu Hr Models B35CEL B70CEL B100CEL...

Страница 2: ...ructure f All fuel storage shall be located a minimum of 762cm 25 feet from heaters torches welding equipment and similar sources of ignition exception the fuel reservoir integral with the heater unit...

Страница 3: ...eck items for any shipping damage If heater is damaged promptly inform dealer where you bought heater FUELS WARNING Useonlykerosene or No 1 fuel oil to avoid risk of fire or explosion Never use gasoli...

Страница 4: ...s Line up holes on fuel tank flange with holes on wheel sup port frame 4 Place front handle and rear handle on top of fuel tank flange Insert screws through handles fuel tank flange and wheel support...

Страница 5: ...n chamber This air is heated and provides a stream of clean hot air The Ignition System The ignition control assembly provides power to the ignitor This ignites the fuel air mixture in the com bustion...

Страница 6: ...lters page 10 See Fuel Filter page 8 See Fan page 13 WARNING Never service heater while it is plugged in operating or hot Severe burns and electrical shock can occur Item Fuel tank Air output and lint...

Страница 7: ...6 Dirty photocell lens 7 Bad electrical connection between photocell and ignition control assembly 8 Defective photocell 9 Defective ignition control assembly TROUBLESHOOTING Continued FAULT CONDITION...

Страница 8: ...lace side cover FUEL FILTER B100CEL and B150CEL Models 1 Remove side cover screws using 5 16 nut driver 2 Remove side cover 3 Pull upper fuel line off fuel filter neck 4 Carefully pry bushing lower fu...

Страница 9: ...lacement CAUTION Donotbendorstrike ignitor element Handle with care 6 Remove combustion chamber Stand combustion chamber on end with nozzle adapter bracket on top see Fig ure 12 7 Remove ignitor screw...

Страница 10: ...re Turn relief valve to right to increase pressure Turn relief valve to left to decrease pressure See specifications below for correct pres sure for each model 5 Remove pressure gauge Replace pres sur...

Страница 11: ...dapter see Fig ure17 18 or19 andfromfuelfilter see page 8 If air line hose is damaged dis connect from nozzle adapter see Figure 17 18 or 19 and from barb fitting on pump end cover see Figure 22 5 Ins...

Страница 12: ...ter end cover 11 Replace fan guard and upper shell 12 Adjust pump pressure see page 10 Note If rotor is still binding proceed as follows 13 Perform steps 1 through 6 above 14 Place fine grade sandpape...

Страница 13: ...he ignition control assembly seeFigure30 Repeatthisfor the other four printed circuit board sup ports then remove the assembly CAUTION Ignition control assemblycontainselectrostatic components Handlet...

Страница 14: ...9 1 9 3 9 4 9 5 17 18 19 20 21 22 23 24 26 27 28 29 30 34 35 36 32 33 9 6 15 14 31 42 41 43 40 38 37 39 25 ILLUSTRATED PARTS BREAKDOWN B35CEL MODEL Motor and Pump Assembly 12 11 12 18 12 17 12 16 12 1...

Страница 15: ...4108 379 Steel Ball 1 4 Diameter 1 12 14 4109 708 Output Filter 1 12 15 4108 536 Screw 10 32 x 1 1 8 6 12 16 4100 661 Nylon Elbow 90 1 12 17 4101 666 Blade 4 12 18 4108 590 Screw 10 32 x 3 4 2 12 19...

Страница 16: ...9 1 9 3 9 4 9 5 17 18 19 20 21 22 23 24 26 27 28 29 30 34 35 36 32 33 9 6 15 14 31 42 41 43 40 38 37 39 25 ILLUSTRATED PARTS BREAKDOWN B70CEL MODEL Motor and Pump Assembly 12 11 12 18 12 17 12 16 12 1...

Страница 17: ...13 4108 379 Steel Ball 1 4 Diameter 1 12 14 4109 708 Output Filter 1 12 15 4108 528 Screw 10 32 x 1 6 12 16 4100 661 Nylon Elbow 90 1 12 17 4101 200 Blade 4 12 18 4108 588 Screw 10 32 x 5 8 2 12 19 41...

Страница 18: ...28 20 22 21 30 31 17 14 14 35 36 32 26 13 18 5 4 6 7 8 7 2 7 1 7 5 7 4 7 3 7 6 43 42 41 33 34 37 40 39 44 38 29 ILLUSTRATED PARTS BREAKDOWN B100CEL MODEL Motor and Pump Assembly 10 1 10 2 10 3 10 4 1...

Страница 19: ...trol Assymbly 1 PARTS LIST B100CEL Model This list contains replaceable parts used in your heater When ordering parts be sure to provide the correct model and serial numbers from the model plate then...

Страница 20: ...28 20 22 21 30 31 17 14 14 35 36 32 26 13 18 5 4 6 7 8 7 2 7 1 7 5 7 4 7 3 7 6 43 42 41 33 34 37 40 39 44 38 29 ILLUSTRATED PARTS BREAKDOWN B150CEL MODEL Motor and Pump Assembly 10 1 10 2 10 3 10 4 1...

Страница 21: ...0 142 Ignition Control Assembly 1 PARTS LIST B150CEL Model This list contains replaceable parts used in your heater When ordering parts be sure to provide the correct model and serial numbers from the...

Страница 22: ...AND HANDLES B100CEL AND B150CEL MODELS KEY PART PART NO NUMBER DESCRIPTION QTY 1 4110 077 Handles 2 2 4110 144 Screw 8 3 4110 078 Wheel Support Frame 1 4 4110 143 Hex Nut 8 5 4110 084 Wheel 2 1 6 4110...

Страница 23: ...r Hr Gal Per Hr 1 1 28 1 97 52 3 0 79 4 1 1 1 Electric Requirements 230 V 50 Hz Same All Models Amperage Normal Run 8 1 0 1 2 1 2 Hot Air Output CMM CFM 4 140 6 4 225 12 425 14 2 500 RPM 1425 2850 285...

Страница 24: ...portable and convenient For B35CEL and B70CEL models AIR GAUGE KIT 4109 427 For all models Special tool to check pump pressure STANDARD WHEELS AND HANDLE KIT 4103 930 Makes heater even more portable a...

Страница 25: ...conform to the Machinery Directive 98 37 EC including 91 368 EEC and the Low Voltage Directive 73 23 EEC It is further declared that these models conform to the EMC Directive 89 336 EEC amended by 92...

Страница 26: ...r this Warranty is expressly limited to repairing or replacing at DESA International s option any parts which appear to DESA Interna tional upon inspection to have been defective in material or workma...

Отзывы: