background image

WARRANTY INFORMATION

POSE. IN ANY EVENT IMPLIED WARRANTIES INCLUDING
THOSE OF MERCHANTABILITY AND FITNESS FOR A PAR-
TICULAR PURPOSE ARE LIMITED TO THE DURATION OF
THIS EXPRESS WARRANTY.

Any transportation charges, costs of installation, duty,

taxes or any other charges whatsoever must be borne by the
user. DESA International's obligation under this limited War-
ranty shall not include any liability for direct, indirect, incidental,
or consequential damage or delay. If requested by DESA
International, Products or parts for which a warranty claim is
made are to be returned transportation prepaid by user to the
factory. Any improper use, including operation after discovery
of defective or worn parts, operation beyond capacity, substi-
tution of parts not approved by DESA International, or any
alteration or repair by others in such manner as in DESA
International's judgement affects the Product materially and
adversely, shall void this Warranty.

NO EMPLOYEE OR REPRESENTATIVE IS AUTHORIZED
TO CHANGE THIS WARRANTY IN ANY WAY OR GRANT
ANY OTHER WARRANTY UNLESS SUCH CHANGE IS
MADE IN WRITING AND SIGNED BY AN OFFICER OF DESA
INTERNATIONAL AT ITS HOME OFFICE.

DESA International warrants new Products sold by it to be

free from defects in material or workmanship for a period of one
year after date of delivery to the first user and subject to the
following conditions:

DESA International's obligation and liability under this

Warranty is expressly limited to repairing or replacing at DESA
International's option, any parts which appear to DESA Interna-
tional upon inspection to have been defective in material or
workmanship when shipped from the factory. Such parts shall
be provided at no cost to the user, at the business establishment
of any factory authorized service center or the factory during
regular working hours. The Warranty shall not apply to compo-
nent parts or accessories of Products not manufactured by
DESA International and which carry the warranty of the manu-
facturer thereof, or to normal maintenance (such as pressure
adjustments) or to normal maintenance parts (such as filters
and spark plugs). Replacement or repair parts installed in the
Product covered by this Warranty are warranted only for the
remainder of this Warranty as if such parts were original compo-
nents of said Product. DESA INTERNATIONAL MAKES NO
OTHER EXPRESS WARRANTY. TO THE EXTENT PERMIT-
TED BY LAW DESA INTERNATIONAL MAKES NO IMPLIED
WARRANTY AND MAKES NO WARRANTY OF MER-
CHANTABILITY OR FITNESS FOR ANY PARTICULAR PUR-

CERTIFICATE OF GENERAL

EQUIPMENT - LIMITED ONE YEAR WARRANTY

WARRANTY SERVICE

Always specify model and serial numbers when communicating
with the factory.

We reserve the right to amend these specifications at any time
without notice. The only Warranty applicable is our standard
written Warranty. We make no other Warranty, expressed or
implied.

A Service Manual is available by writing to the Technical Service
Department at:

Corporate Headquarters
2701 Industrial Drive
P.O. Box 90004
Bowling Green, Kentucky 42102-9004
U.S.A.

Содержание B100CEL

Страница 1: ...ing start ing or servicing heater Improper use of heater can cause serious injury Keep this manual for future reference R Heater Sizes 35 000 70 000 100 000 150 000 Btu Hr Models B35CEL B70CEL B100CEL...

Страница 2: ...ructure f All fuel storage shall be located a minimum of 762cm 25 feet from heaters torches welding equipment and similar sources of ignition exception the fuel reservoir integral with the heater unit...

Страница 3: ...eck items for any shipping damage If heater is damaged promptly inform dealer where you bought heater FUELS WARNING Useonlykerosene or No 1 fuel oil to avoid risk of fire or explosion Never use gasoli...

Страница 4: ...s Line up holes on fuel tank flange with holes on wheel sup port frame 4 Place front handle and rear handle on top of fuel tank flange Insert screws through handles fuel tank flange and wheel support...

Страница 5: ...n chamber This air is heated and provides a stream of clean hot air The Ignition System The ignition control assembly provides power to the ignitor This ignites the fuel air mixture in the com bustion...

Страница 6: ...lters page 10 See Fuel Filter page 8 See Fan page 13 WARNING Never service heater while it is plugged in operating or hot Severe burns and electrical shock can occur Item Fuel tank Air output and lint...

Страница 7: ...6 Dirty photocell lens 7 Bad electrical connection between photocell and ignition control assembly 8 Defective photocell 9 Defective ignition control assembly TROUBLESHOOTING Continued FAULT CONDITION...

Страница 8: ...lace side cover FUEL FILTER B100CEL and B150CEL Models 1 Remove side cover screws using 5 16 nut driver 2 Remove side cover 3 Pull upper fuel line off fuel filter neck 4 Carefully pry bushing lower fu...

Страница 9: ...lacement CAUTION Donotbendorstrike ignitor element Handle with care 6 Remove combustion chamber Stand combustion chamber on end with nozzle adapter bracket on top see Fig ure 12 7 Remove ignitor screw...

Страница 10: ...re Turn relief valve to right to increase pressure Turn relief valve to left to decrease pressure See specifications below for correct pres sure for each model 5 Remove pressure gauge Replace pres sur...

Страница 11: ...dapter see Fig ure17 18 or19 andfromfuelfilter see page 8 If air line hose is damaged dis connect from nozzle adapter see Figure 17 18 or 19 and from barb fitting on pump end cover see Figure 22 5 Ins...

Страница 12: ...ter end cover 11 Replace fan guard and upper shell 12 Adjust pump pressure see page 10 Note If rotor is still binding proceed as follows 13 Perform steps 1 through 6 above 14 Place fine grade sandpape...

Страница 13: ...he ignition control assembly seeFigure30 Repeatthisfor the other four printed circuit board sup ports then remove the assembly CAUTION Ignition control assemblycontainselectrostatic components Handlet...

Страница 14: ...9 1 9 3 9 4 9 5 17 18 19 20 21 22 23 24 26 27 28 29 30 34 35 36 32 33 9 6 15 14 31 42 41 43 40 38 37 39 25 ILLUSTRATED PARTS BREAKDOWN B35CEL MODEL Motor and Pump Assembly 12 11 12 18 12 17 12 16 12 1...

Страница 15: ...4108 379 Steel Ball 1 4 Diameter 1 12 14 4109 708 Output Filter 1 12 15 4108 536 Screw 10 32 x 1 1 8 6 12 16 4100 661 Nylon Elbow 90 1 12 17 4101 666 Blade 4 12 18 4108 590 Screw 10 32 x 3 4 2 12 19...

Страница 16: ...9 1 9 3 9 4 9 5 17 18 19 20 21 22 23 24 26 27 28 29 30 34 35 36 32 33 9 6 15 14 31 42 41 43 40 38 37 39 25 ILLUSTRATED PARTS BREAKDOWN B70CEL MODEL Motor and Pump Assembly 12 11 12 18 12 17 12 16 12 1...

Страница 17: ...13 4108 379 Steel Ball 1 4 Diameter 1 12 14 4109 708 Output Filter 1 12 15 4108 528 Screw 10 32 x 1 6 12 16 4100 661 Nylon Elbow 90 1 12 17 4101 200 Blade 4 12 18 4108 588 Screw 10 32 x 5 8 2 12 19 41...

Страница 18: ...28 20 22 21 30 31 17 14 14 35 36 32 26 13 18 5 4 6 7 8 7 2 7 1 7 5 7 4 7 3 7 6 43 42 41 33 34 37 40 39 44 38 29 ILLUSTRATED PARTS BREAKDOWN B100CEL MODEL Motor and Pump Assembly 10 1 10 2 10 3 10 4 1...

Страница 19: ...trol Assymbly 1 PARTS LIST B100CEL Model This list contains replaceable parts used in your heater When ordering parts be sure to provide the correct model and serial numbers from the model plate then...

Страница 20: ...28 20 22 21 30 31 17 14 14 35 36 32 26 13 18 5 4 6 7 8 7 2 7 1 7 5 7 4 7 3 7 6 43 42 41 33 34 37 40 39 44 38 29 ILLUSTRATED PARTS BREAKDOWN B150CEL MODEL Motor and Pump Assembly 10 1 10 2 10 3 10 4 1...

Страница 21: ...0 142 Ignition Control Assembly 1 PARTS LIST B150CEL Model This list contains replaceable parts used in your heater When ordering parts be sure to provide the correct model and serial numbers from the...

Страница 22: ...AND HANDLES B100CEL AND B150CEL MODELS KEY PART PART NO NUMBER DESCRIPTION QTY 1 4110 077 Handles 2 2 4110 144 Screw 8 3 4110 078 Wheel Support Frame 1 4 4110 143 Hex Nut 8 5 4110 084 Wheel 2 1 6 4110...

Страница 23: ...r Hr Gal Per Hr 1 1 28 1 97 52 3 0 79 4 1 1 1 Electric Requirements 230 V 50 Hz Same All Models Amperage Normal Run 8 1 0 1 2 1 2 Hot Air Output CMM CFM 4 140 6 4 225 12 425 14 2 500 RPM 1425 2850 285...

Страница 24: ...portable and convenient For B35CEL and B70CEL models AIR GAUGE KIT 4109 427 For all models Special tool to check pump pressure STANDARD WHEELS AND HANDLE KIT 4103 930 Makes heater even more portable a...

Страница 25: ...conform to the Machinery Directive 98 37 EC including 91 368 EEC and the Low Voltage Directive 73 23 EEC It is further declared that these models conform to the EMC Directive 89 336 EEC amended by 92...

Страница 26: ...r this Warranty is expressly limited to repairing or replacing at DESA International s option any parts which appear to DESA Interna tional upon inspection to have been defective in material or workma...