Pagina 12
W
I
C
LOUD
1. TECHNICAL DATA
Model
WiCloud
Compression and tensile force
200 N
Strokes
70, 125, 170, 210mm
Power supply voltage
24 V
Current absorbed at nominal load
0.32A
Power absorbed at nominal load
7.5W
No-load traverse speed
8mm/s
No-load stroke time (215 mm)
27 s
Service type
S
2
of 3 min
Operating temperature
- 5 + 65 ºC
Degree of protection for electrical devices
IP32
Synchronized operation
NOT provided for
Static seal strength
1000N
Opening stroke-end
Electronic, set by dip-switches
Closing stroke-end
By power absorption
Power supply cable length
2m
Chain outlet
Central
Dimensions
28x28x310mm
Device weight
0.660kg
The technical data provided above is non-binding and subject to change, even without advance notice.
Selecting the cross-section of the power supply cables
2. RATING AND MARKING
The rating data is provided on an adhesive polyethylene label attached
to the exterior of the device. The values are compliant with that required
by the EC standards in force. An example of the label is shown in the
photo below.
Cable cross section
Max cable length
4.00 mm²
~ 270 m
2.50 mm²
~ 170 m
1.50 mm²
~ 100 m
0.75 mm²
~ 50 m
0.50 mm²
~ 35 m
E