Disinfecting the Piping System with Chlorine: 

 

1.

  Shut off the water to the inlet and outlet of the cartridge filter.   

2.

  Remove the cartridge sump and empty all water.  Fill with household chlorine (Clorox, non-

scented), 5.25% sodium hypochlorite. 

3.

  Re-install the sump to the filter assembly and open the inlet and outlet valves. 

4.

  Open the cold water faucet at the farthest point in the piping until you detect chlorine odor.  

Once the odor is detected, close that faucet.  Continue this procedure until the chlorine odor 

has been detected at every faucet.  If chlorine odor is not detected at all faucets, repeat 

steps 1 through 4. 

5.

  Close ball valve on outlet of cartridge filter. 

6.

  Allow the water to stand for at least (4) hours to kill the bacteria residual in the piping 

system.   

 

** 

No water should be used during disinfection. ** 

 

Before consumption of water, an EPA Lab Test is suggested.

 

 

 

MWC-EM SERIES 

 

TROUBLESHOOTING 

 

Symptom:  No flow of water no Alarm and Gland Nut not glowing  

 

                   Cause 

                                 Solution 

Electric Supply 

Check electrical outlet and breaker box for power. 

Replace fuse in Meter Power Supply 

 

Symptom:  No flow of water no Alarm and 

Gland Nut

 is 

glowing blue

 and meter is reading 100% 

 

Cause 

Solution 

 

Solenoid 

Turn off water and release pressure to the MWC-EM unit. 

Remove solenoid coil and clean port and plunger. 

Defective solenoid replace

 

 

Symptom: Alarm is on and no flow of water and Meter is reading less than 50% and Lamp is on 

and 

Gland Nut

 is 

glowing

 

blue.

 

 

                     Cause 

                                 Solution 

Lamp is over a year old 

Replace lamp 

   See Germicidal Lamp Replacement. 

 

Quartz Sleeve is dirty 

Remove quartz sleeve and  

UV quartz eye dirty 

Remove Quartz Eye and clean  

 

Symptom: Alarm is on and no flow of water and Lamp is out and Meter is reading 0% 

 

Cause 

Solution 

Lamp  

Replace lamp 

See Germicidal Lamp Replacement. 

 

Remove quartz sleeve and clean 

 

Remove Quartz Eye and clean  

 

 

Содержание MWC-EM Series

Страница 1: ...MWC EM Series Ultraviolet Sterilizers MWC EM7 MWC EM10 MWC EM20 Installation and Operation Manual 2022 VERSION...

Страница 2: ...ts MWC Meter Power Supply Meter Power Supply Installation 7 Grounding Grounding Instructions 8 Quartz and O ring Installing Quartz and O ring Germicidal Lamp Installing Germicidal Lamp MWC EM Meter St...

Страница 3: ...of our MWC EM Water Sterilizers Shipping Description The UV unit is shipped complete as follows The large box contains the UV vessel and inside that box you will also find the following 1 A box conta...

Страница 4: ...the maximum allowable levels specified this will result in bacteria passing through the UV unit and into the piping system Unit Location 1 The MWC EM unit must be installed after the well tank and any...

Страница 5: ...ng the quartz tube and germicidal lamp For proper clearance see Specification Table on page 2 6 Secure the bottom bracket to the wall by using three screws or fasteners not provided 7 Use quality unio...

Страница 6: ...ring this is on the quartz eyepiece 4 Insert the UV sensor assembly with gray gland nut Hand tighten only 5 Attach the other end of the UV sensors black amp electrical connection to the lower right s...

Страница 7: ...power 24 hours per day We recommend installing a surge protector to protect unit from power surges which are not covered by warranty DO NOT UNDER ANY CIRCUMSTANCE WIRE THE UV UNIT TO THE WELL PUMP SW...

Страница 8: ...rly grounded The vessel must be grounded to the MWC Power Supply to make a complete ground MWC SERIES Grounding Lug Installation Grounding Lug Front View of Bracket Insert stripped green ground wire i...

Страница 9: ...3 Gently insert the germicidal lamp into the quartz sleeve through the center of the clear gland nut located at the top of the vessel Be careful not to drop the lamp inside the vessel This could break...

Страница 10: ...ses interference in the UV vessel 1 Shut off the water to the inlet and outlet of the cartridge filter 2 Remove the cartridge sump and empty all water Fill with household chlorine Clorox non scented 5...

Страница 11: ...tlet with power 24 hours per day 3 Check all piping for leaks repair if necessary 4 Unplug the 1 normally closed solenoid from the electrical outlet and plug the solenoid into the lower right side of...

Страница 12: ...driver Remove the black cap located on the upper right side of the meter 5 With the unit on and operating turn the lower screw clock wise turn at time until you reach 100 The MWC EM unit is now workin...

Страница 13: ...y pulling up on the gray harness wire and discard the lamp Remember the lamp is glass and can cause injury to you if the lamp is dropped 5 Open the ball valve test port on outlet side of UV unit to de...

Страница 14: ...port and plunger Defective solenoid replace Symptom Alarm is on and no flow of water and Meter is reading less than 50 and Lamp is on and Gland Nut is glowing blue Cause Solution Lamp is over a year o...

Страница 15: ...where the ultraviolet sterilizer has been operated at pressure in excess of 100 pounds per square inch or at a temperature in excess of 100 degrees F or below 32 degrees F Incidental costs or conseque...

Страница 16: ...driver Remove the black cap located on the upper right side of the meter 5 With the unit on and operating turn the lower screw clock wise turn at time until you reach 100 The MWC EM unit is now workin...

Страница 17: ...nnection to the lower right side of the meter Insert the amp into the twist lock connector The connector will only fit into the connector one way Hand Tighten Only UV Sensor Assembly Quartz Dome Eyepi...

Страница 18: ...nt is required before installation of the UV unit Water must meet criteria below Untreated Water Quality Maximum Allowable Level Chloride 250 00 ppm Color 0 00 units Hardness 8 00 gpg Iron 0 30 ppm Ma...

Страница 19: ...ore consumption of water an EPA Lab Test is suggested MWC EM SERIES TROUBLESHOOTING Symptom No flow of water no Alarm and Gland Nut not glowing Cause Solution Electric Supply Check electrical outlet a...

Отзывы: